PRODUCT DESCRIPTION
SALTO Neoxx Padlock is a battery operated electronic padlock that brings all
the advantages and benefits of an access control without wiring the door
reducing installation costs and allowing you to control and manage virtually
any kind of door.
The SALTO Neoxx Padlock offers a unique solution for all those projects that
needs an additional level of security to control very specific doors, gates or
storages, without losing a piece of convenience and control.
A wire free fully stand-alone electronic access control solution, it is
suitable for installation in almost every type of situations that requeires a
padlock locking solution.
WHATS IN THE BOX
When you purchase a SALTO Neoxx Padlock, you get:
- SALTO Neoxx electronic poadlock
- 4 battery LR1 type (SALTO just warrantee the correct and best autonomy with Alkaline LR1 Energivm batteries)
- Installation guide
WARNING: for the maintenance of the cylinder in order to perform replacement of batteries, SALTO recommends to purchase the Installation tool (SP226009 – sold separately).
ACCESSORIES
- Battery replacement tool (SP226009).
- 4 LR1 battery for SALTO Neo cylinders (SP01926-5).
WARNING: “ The product should not be modified in any way except in accordance with those modifications described in the instructions”.
Padlock RANGE
MODELS
P4 = Padlock. NxP4xx..
DIMENSIONS
CERTIFICATIONS
- CE
- FCC
- IC
- RCM
- MIC
- EN 16864 (1 1 4 4 – D 3 4)
- IEC 60529 (IP66)
TECHNICAL DATA
-
CURRENT REQUIRED 4 x LR1 batteries.
-
ENVIRONMENTAL CONDITIONS:
-20 C / +55 C (without condensation).
-35 ºC / +55 ºC (exterior, only MIFARE).
() Battery life reduced significally. -
ACCESS CONTROL SYSTEM:
-
RW System.
-
SALTO KS System.
ACCES CONTROL FEATURES
RW System | SALTO KS System | |
---|---|---|
Maximum number of users per door | 4,000,000 | 1000 for IQ1 |
10000 for IQ2
Maximum number of door per system| 65,000| Unlimited
Maximum events on lock audit| 2,200| 1462 (BLUEnet)
472 (RFnet)
Time zones| 1,024| –
Time periods| 256| 128
Calendars in system| 256| –
User groups| Unlimited| Unlimited
Management software| ProAccess SPACE| SALTO KS
OPENING MODELS
- STANDARD: locked at all times.
- OFFICE: Free passage ability.
- TIMED OFFICE: free passage with automatic locking.
- AUTOMATIC OPENING: 8 pairs of “hands free” timed lock and unlocks per day with holidays.
- AUTOMATIC OPENING + OFFICE.
- TOOGLE: present card to lock, present card to unlock.
- TIME TOOGLE: present car to lock, present card to unlock depending on schedules.
- TWO PERSON RULE: present two valid cards to unlock.
TIMEZONES
Each user can be assigned to a calendar and a time table consists of up to 8
different time intervals with a resolution of 10 minutes assigned to each day
of the week. You can also distinguish between holidays, special days and
working days.
EVENT AUDITOR
- Authorized access events auditor registration, denied access events auditor registration, system maintenance events auditor registration (low battery, PPD connection,…) and automatic actions events auditor registration (automatic opening…).
- Each events is logged: event type, user, date and time of the event.
- Permanent events registration. Non-volatile memory of the last X events (see table).
- The events are saved in a non-volatile memory, so the events are recored forever.
- The events are saved in a “Ring buffer” system. When the event storage capacity is full, creating a new event removes the last one.
INSTALLATION
To install the SALTO Neoxx Padlock: following the instructions attached with
the product, or visiting our website:
www.saltosystems.com/en/quick-links/manuals-and-
guides/
PROGRAMMING
To grant or deny access permissions are used to the right SW license. Once you update the system configuration:
- RW SYSTEM: the system allows electronic cylinders to read, receive and write information via its operating smart cards or “intelligent keys”. This data is captured from the cards at SVN on-line hot spots located at strategic points around the building. The “online points” uploads and downloads user related information that is then used to permit, control or deny access.
- KS SYSTEM: the system allows electronic cylinders to read, receive and write information via radio SALTO KS.
BATTERIES
In the case of complete battery failure the product both safe and secure, i.e.
the outside handle fails “locked” to avoid intrusions, the inside handle fails
“open” to permit emergency openings.
If the batteries are removed, the product does not work. If they are put back
again, the product works but it loses the RTC. If it is an online access
point, the RTC is recovered instantly. If not, the access point must be
programmed again. When the product has lost the RTC, if the user does not have
time restrictions, it opens. However, if the user has time restrictions, the
access point does not open even if the user has access to it.
There are 3 different posibilites regarding the power level of the batteries:
- Low level batteries: “Low battery status” signalization, the event is recorded and the access point opens when a valid card is presented.
- Very low batteries: “Low battery status” signalization, the event is recorded but the access point does not open even if a valid card is presented.
- Extremely low level batteries: the access pint does not work.
WARNING: electronic cylinder in standalone or offline mode needs to be update with the PPD to recover the hour. “The product should not be modified in any way except in accordance with those modifications described in the instructions”.
SALTO just warrantee the correct and best autonomy with Alkaline LR1 Energivm – batteries (SP01926-5).
SALTO Neo SIGNALS
ACCESS GRANTED
Present a valid user key and get the access granted.
ACCESS DENIED
Present a not valid user key and get the access denied.
LOW BATTERY STATUS
After presenting a valid user card that has access to the door and opening the
door, the cylinder will show 4 light red signal and then grant the access.
BATTERY CHANGE (RESET)
Each time you change the batteries, the electronic will do a reset. The
cylinder memory will not be erased.
To show this reset, the cylinder show yellow lights with a lite sound.
OFFICE MODE NOTICE
Present a valid user key, the cylinder show a green ligth with a lite sound.
The cylinder is in “office mode”.
ACCESS GRANTED IN OFFICE MODE
Present a valid user key, the cylinder show 3 green ligths with a lite sound
and get the access granted.
ACCESS DENIED IN OFFICE MODE
Present a not valid user key, the cylinder show red ligths with a lite sound
and get the access denied.
OFFICE MODE END
Present a valid user key, the cylinder show 2 red ligths with a lite sound.
The “office mode” is over.
ACCESS GRANTED + TOOGLE
After presenting a valid user card with “TOOGLE” credentials, the SALTO Neo
cylinder will start the “TOOGLE” mode. This will be shown by 3 green lights
and high pitched beeps.
END TOOGLE
After presenting a valid user card with “TOOGLE” credentials, the SALTO Neo
cylinder will end the “TOOGLE” mode. This will be shown by 2 red lights and
low pitched beeps.
SECURITY ERROR
When the cylinder shows continuous blinking light Finished and a combination
of high and low pitched beeps and yellow lights, it means that the knob and
the cylinder are not paired and they can not be mounted together.
CONFIDENTIAL – This document contains confidential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L. – © SALTO Systems 2020 SALTO reserves the rights to modify technical specifications, designs and performance without notice.