Warmup RSWNA Programmable WIFI Thermostat with/without GFCI Instruction Manual
- June 6, 2024
- Warmup
Table of Contents
WiFi Thermostat
Smart Heating. Simplified.
View all Warmup thermostat manual
Welcome to the Terra thermostat. The Terra is a Wi-Fi-enabled thermostat designed to provide timed regulation of electric underfloor heating systems.
- Heating Indicator
- Current Floor / Air temperature
- Up / Down;
- Change value / setting
- Back / Cancel
- Next / Accept
- GFCI Test Button
Pack Contents
1 x Terra thermostat
(Display & Power Base) with installation manual
1 x 3m NTC10K Sensor
2 x screws
- The thermostat must be installed by a qualified electrician. It requires a permanent 110V – 240V AC, 60Hz supply. The thermostat contains a Class A GFCI with a 5mA trip level and wiring must conform to local electrical code.
- Isolate the thermostat from the main supply throughout the installation process.
- Conduits are only required where it is mandated by state or provincial code. Please refer to the local electrical code for compliant applications.
- The thermostat and its packaging are not toys; do not allow children to play with them. Small components and packaging present a risk of choking or suffocation.
- The thermostat is suitable for indoor use only. It must not be exposed to moisture, vibrations, mechanical loads, or temperatures outside of its rated values.
- For safety and licensing reasons, unauthorized change and/or modification of the thermostat is not permitted.
- Ensure the distance from your router to the thermostat is not excessive. This will ensure the wireless connection is not subject to range or interference issues once installed.
- Install the thermostat in an area with good ventilation.
It should not be beside a window/door, in direct sunlight, or above another heat-generating device (e.g. radiator or TV).
- Isolate the thermostat from the main supply.
- Unclip the display from the power base and remove the display
- DO NOT install the thermostat near a window/door, in direct sunlight, or above another heat-generating device (e.g. radiator or TV).
- Ensure distance from the router to the thermostat is not excessive to reduce range or interference issues.
- Install a 3-1/2” (89 mm) deep single gang or 2-gang box with mud ring in your preferred thermostat location. Pull wires (heater, supply and sensor) through gang box and complete terminal wiring.
The thermostat must be installed by a qualified electrician in accordance with National Electrical Code.
A1. Thermostat in room
A2. Thermostat out of room
A3. Thermostat in/out of room
B1.Air temperature schedule
B2.Floor temperature schedule
C1. Floor limit
C2.Air limit
C3.No floor limit
| Internal air sensor
---|---
| Floor sensor
| Air sensor
| Recommended when the thermostat is out of the heated room
| Recommended when the thermostat is in the heated room
| Electric underfloor heating
---|---
| Hydronic underfloor heating
| Conventional
| Electric + relay
| Input wattage
| Input efficiency
| |
---|---|---
WIRING CONNECTIONS****
LOAD L1 & L2 | Heater Load Max. 15A (1800W – 120 V, 3600W – 240 V) |
---|---|
LINE L1 | Supply Live (120 V) |
LINE L2 | Supply Neutral (120 V) / Supply Live (240 V) |
P1 & PC | Probe 1 – Floor/Air Control Sensor (No Polarity) |
P2 & PC | Probe 2 – Limit Sensor (No Polarity) |
See thermostat applications. Scan QR code, step 9, for online user guide which
contains additional thermostat applications.
NOTE: The function of Probe 1, Probe 2 from Control/Limit Sensor can be
swapped in settings.
- Insert fixing screws through mounting holes of the power base and tighten. Re-attach the display to the power base and restore power to the thermostat. Follow the on-screen icons to set up your system.
- Download the MyHeating App.
- Open the My Heating App and scan the QR Code on the thermostat screen protector/reverse of the display and follow the instructions in the App to complete setup.
- Scan the QR Code for the full online user guide.
Model | RSW-XX-YY-ZZ |
---|---|
Voltage | 110V – 240V AC +/-15% 50Hz/60Hz |
Protection | |
Max. Load | 15A resistive (120 V – 1800 W 240 V – 3600 W) |
GFCI | Class A GFCI with 5mA trip level |
Rated impulse voltage | 4000V |
Automatic action | 100,000 |
Disconnection means | 1B |
Pollution degree | 2 |
Max. Ambient Temperature | 40°C / 104°F (T40) |
Relative Humidity | 80% |
IP Rating | IP30 |
Sensors | Floor/Air |
Sensor Type | NTC10K @ 25°C |
Operating Frequency | 2401 – 2484MHz |
Max. Radio-Frequency
Power Transmitted| 20dBm
Compatibility| Electric underfloor heating
Standards| UL-60730-1 UL-60730-2-9 UL-943
CAN/CSA-E60730-1
CAN/CSA-E60730-2-9
CAN/CSA-C22.2 No. 144.1
FCC 47 CFR Part 15, ICES-003
Guarantee
12 Warmup plc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of twelve (12) years from the date of purchase by the consumer when installed with a Warmup heater.
If at any time during the warranty period the product is determined to be
defective, Warmup shall repair or replace it, at Warmup’s option. If the
product is defective, please either;
Return it, with a bill of sale or other dated proof of purchase, to the place
from which you purchased it, or Contact Warmup. Warmup will determine whether
the product should be returned or replaced.
The twelve (12) year warranty only applies if the product is registered with
Warmup within 30 days after purchase. Registration can be completed online at
www.warmup.com This warranty does not cover removal
or re-installation costs and shall not apply if it is shown by Warmup that the
defect or malfunction was caused by failure to follow the instruction manuals,
incorrect installation, or damage that occurred while the product was in the
possession of a consumer. Warmup’s sole responsibility shall be to repair or
replace the product within the terms stated above. If the thermostat is
installed with a non-Warmup heater a three (3) year warranty will apply. This
warranty does not extend to any associated software such as apps or portals.
WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM
ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MADE ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
TWELVE-YEAR DURATION OF THIS WARRANTY.
This warranty does not affect your statutory rights.
Important Notices
FCC Notice
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses, and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio TV technician for help.
Caution: To maintain compliance with the RF exposure guidelines, place the
unit at least 8″ (20 cm) from nearby persons.
IC Statement
This device complies with Industry Canada Licenceexempt RSS-247. Operation is
subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including
interference that may cause undesired operation of the device.
Caution: To maintain compliance with the RF exposure guidelines, place
the unit at least 8″ (20 cm) from nearby persons.
GFCI Notice
The GFCI feature is used to detect any leakage of current from your heating
system. During a ground fault, the two lines of the load will be cut off. Once
your thermostat is installed and connected to a power supply you can test the
GFCI function by increasing the set temperature until heating is on – the heat
up icon will be illuminated – and pressing the “TEST” button.
If your test is successful you will see the GFCI error icon and you will need
to hold “X” for 3 seconds in order to restore heating operation.
In the following circumstances, you should immediately isolate the power
supply to the thermostat and contact our helpline:
If the thermostat detects that one of the relays has FAILED.
If the GFCI icon does not appear having pressed the test button.
NOTE: The GFCI test should be carried out monthly.
Contact
Warmup Inc.
25-A Francis Clarke
Circle, Bethel,
CT 06801
W: www.warmup.com
E: us@warmup.com
T: 888-927-6333
F: 888-927-4721
Warmup Canada
W: www.warmup.ca
T: 888-592-7687
F: 888-927-4721
https://thermostat.guide/warmup/warmup-rswna-programmable-wifi-thermostat- instruction-manual/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>