Installation instructions R3000WCM
Warning!
High voltage. Risk of electric shock. The installation should only be carried
out by an authorized electrician.
Ensure that the power supply to the relay is switched off before connection.
The Bluetooth relay R3000WCM is controlled by one or multiple attractive switches and/or through the Casambi app which is free to download from Appstore and Google Play. The relay is used to control non-dimmable loads up to an interrupting rating of 13A (cos φ =1).
To control a relay in Casambi, the function “Control an element” is used.
Connection
- Make sure that the power is shut off before the connection begins.
- Connect the neutral wire to the terminal input marked N.
- Connect phase wire to the terminal input marked L.
- Connect the control wire S1 to the retractive switch.
- Connect phase wire to the other side of the retractive switch.
- Connect interrupting output L’ to the load. Connect the neutral wire to the load.
- Make sure that the spring installed on the retractive switch and all connections above are correct.
- Put the power back on.
To be able to use the retractive switch inputs S1 and S2, you need to
configure this in the app. The retractive switch inputs are set as “not used”
in the factory settings.
Tip!
You can use the extra retractive switch input S2 to control a scene in the
Casambi-network, for instance.
Wiring diagram
Technical data
Designation | R3000WCM |
---|---|
Art. number | V-42B0106-001Y |
E-number | 13 013 45 |
Power | 0-3000VA |
Input voltage | 220-240V |
Frequency | 50Hz |
Frequency band | 2402MHz-2480MHz |
Maximum radio-frequency power | 4dBm |
Standby power | <0,5W |
Maximum interrupt rating | 13A (cos φ =1) |
Control signals (ON/OFF) | Can be controlled with one or multiple retractive |
switches or via Casambi
Remembers the last set state| Yes, even after a power outage
Overheat-protection| Yes
Mounting| Wall mount box
Operating humidity| 0…80% non-condensing
Operating temperature| -20°C + 30°C
Dimensions LxWxH| 47,5×47,5x20mm
Weight| 45g
Cable area| 2,5mm2 (AWG 22)
Housing material| Polycarbonate (PC)
Usage areas| Control non-dimmable loads up to an interrupting rating of 13A
(cos φ=1)
Insulation class| IP20
Cladding class| II
Authorizations| CE
Heat
R3000WCM is equipped with overheat protection. When used continuously for a
long time with a high load in a warm environment, the relay will shut off. If
the relay is installed in a warm environment or if multiple relays are
installed tightly together, then the maximal output of the relay needs to be
reduced. Pay attention to that long cable lengths will increase the heat
because of the cable’s resistance.
Change profile
The relay’s profile can be changed when it is not connected to a network. By
pressing on the unit in the Casambi-app in the nearby devices, the option to
change profile shows up. By changing the profile, the function of the device
is changed.
Profiles:
R3000WCM ON/OFF: The relay is activated/deactivated by pressing the
button.
R3000WCM ON WHILE PRESS: The relay is active while the button is held
pressed.
Create an impulse function in Casambi with a custom pulse length
- Create a scene with the relay on – “Relay on”.
- Create a scene with the relay off – “Relay off”.
- Create an animation “Impulse”.
- First, add the scenario “Relay on” to the animation “Impulse”.
- Add a delay, which will be the length of the pulse.
- Then add the scenario “Relay off”.
- Activate the animation “Impulse” through the app or through a retractive switch.
Range
MESH means that the devices talk to each other via the Bluetooth network, and
you only need to have coverage for one device. By using MESH technology, you
only need to be within the range (30M max) of one device in order to control
all devices. The MESH technology means that you can build large-scale
installations with a large number of light fittings and control them easily,
e.g. via your smartphone. We recommend 10m as all installations have different
pre-conditions. Note that even a dimmer with no load can be used in the
network as a presence enhancement through the network via MESH technology
Load
The interrupting rating of 13A is valid on resistive loads. Different types of
loads have different inrush currents when activated and voltage spikes when
deactivated. To maximize the life span of R3000WCM it is recommended to follow
the values given in the table below (given that the installation environment
isn’t too hot).
Load | PF | Rated output | VA | A |
---|---|---|---|---|
Halogen 230V | 1 | 3000W | 3000VA | 13A |
LED-loads | 0,9 | 650W | 800VA | 3,25A |
Fluorescent tube uncompensated | 0,3 | 570W | 1870VA | 8,125A |
Fluorescent tube compensated | 0,85 | 1220W | 1420VA | 6,5A |
Low voltage halogen electronic | 0,8 | 1220W | 1420VA | 6,5A |
Low voltage halogen conventional | 0,95 | 975W | 975VA | 4A |
Low-energy bulbs | 0,6 | 400W | 650VA | 3,25A |
Dimensions