VADSBO CBU-ASD Control Module Instruction Manual
- June 4, 2024
- VADSBO
Table of Contents
CBU-ASD Control Module
**Instruction Manual
**
CBU-ASD Control Module
Warning!
High voltage. Risk of electric shock or fire.
The installation must only be performed by a competent electrician. Disconnect
the power supply to the primary side och and ensure it is switched off prior
to installation.
Description
CBU-ASD is a wireless controller for LED and halogen actuators with 0-10V,
1-10V, or DALI dimming interface. The CBU-ASD is available with either analog
0-10V (and 1-10V) or a digital standalone Dali control interface.
With standalone Dali output, the CM1 0WCM will act both as a controller and
power source, which enables it to connect directly to an LED actuator with a
Dali interface, without the need for an external Dali power source. The so-
called independent Dali makes it possible to implement multi-channel light
systems with adjustable colors (RGB and RGBW) or color temperature (CCT) while
keeping the wiring and the number of components to a minimum.
CBU-ASD does not comply with IEC 60929 and is therefore not designed for
connection to an existing DALI network. The module can only be used in a
closed system, that is to say as part of a system that is not connected to an
external Dali network.
The CBU-ASD is controlled wirelessly via Casambi’s app on a smartphone or
tablet, via the Bluetooth 4.0 protocol. The Casambi-app can be downloaded free
from Apple App Store and Google Play Store.
The devices automatically create a secure wireless mesh network so that a
large number of fixtures can be operated regardless of where you are. No
external distribution node is needed. The CBU-ASD can also be controlled via a
standard on/off-wall switch.
Casambi
uses mesh network technology so that each CBU-ASD also acts as a range
extender. A longer range can be achieved by using several Casambi devices.
- The range is very dependent on the surroundings and obstacles, such as
walls and building materials.
Compatible devices: iPhone 4S or later, iPad 3 or later, iPod Touch 5th gen or later, Android 4.4 KitKat or later devices post-2013 with full BT 4.0 support
Dimming without the app
-
Switch on the light using a wall switch.
-
Quickly switch off the wall switch (after a maximum of 1 second) and then on again in quick succession. The light level begins to increase gradually.
-
Turn off the power switch when the desired level has been achieved. The level is saved automatically.
-
If the light is not switched back on within 8 sec., the light intensity will reach its maximum level.
-
The on/off switch sequence can also be used to switch between preset scenes.
Change the operation of the device:
To change the operation of the device, it must be unplugged from the network.
Click “More” and wait for the device to become visible under “Devices in the
vicinity”, then click on it and choose Change Profile.
1-10V (factory-set profile)
For easy control of devices (actuator, dimmer) with 0-10V-control. The device
can sometimes require an external relay to switch on/off. For 1-10V dimming,
use the profile CBU ASD.
Colour Adjustment
Adjust the color just the way you like it. Go into the connected network, and
double-click on the device. Click “Change fixture state” to alter the light
level, brightness, color, and color saturation. For color adjustment of RGBW,
the profile RGBW [auto] is typically used.
Tunable-White (TW):
Tunable-White (TW) is operated by several adjustable channels which alter the
color temperature of the light source to adjust the shade of output white
light.
DALI
Connect to a DALI fixture and control it easily without programming. For easy
dimming of a DALI fixture, use profile DALI Broadcast.
Alternative control
It is possible to operate the device via external push buttons. It is possible
to control the device both by push buttons connected to actuators/dimmers with
Bluetooth support or directly via push buttons with Bluetooth support. First,
make sure that the desired push button is connected to the same network as the
device you wish to control.
Instructions for disposal
In line with the EU Waste Electrical and Electronic Equipment Directive
(2002/96/EC) (WEEE).
This electrical product may not be disposed of with unsorted municipal waste.
Please dispose of this product by returning it to the store where it was
purchased or to a local municipal recycling center.
Installation
Ensure that the primary side voltage is switched off before the connection is
made. Use 0.75 – 1.5mm² single or multi-strand cables. Strip the cable 6 to
7mm from the end.
Insert the cables into the corresponding holes and tighten the screws on the
terminal block. Make sure that the inputs and outputs are connected correctly.
The primary input connector is marked with the letters L and N with an arrow
pointing inwards, while the primary output connector is marked with the
letters L and N, with an arrow pointing outwards. The low voltage output is
marked with the + and – symbols.
If the installation of the CBU-ASD is carried out in a heat-sensitive
environment (e.g. in a light fixture or a ceiling socket above a light
fixture), make sure that the ambient temperature does not exceed the specified
maximum value.
Circuit diagram for a directly-operated DALI or 0-10V actuator Suitable for
actuators that can be switched off via a control interface.
Wiring
diagram, DALI, or 1-10V actuator operated by an external relay Suitable for
actuators that cannot be switched off via a control interface.
Warning!
Risk of fire. Do not connect the primary side output of the CBU-ASD directly
to the primary side input of the LED actuator.
Dimensions
Note 1. CBU-ASD is a built-in Class II device. Use double insulated
cables or an external mounting box if the device is not mounted inside another
insulation unit.
Note 2. CBU-ASD and the associated DALI interface do not meet the
requirements of IEC 60929. Only connect directly to a controllable DALI LED
actuator. Should not be connected to an existing DALI network. Connect only
one LED actuator (DALI or “0/1-10V” actuator) to a CBU-ASD.
Technical data
Input
Voltage range| 220-240 VAC
Frequency| 50 Hz
Maximum primary current| 0,6 A
Output relay
Voltage Range| SSR in phase
Frequency| 220-240 VAC
Primary output| 50 Hz
Maximum start-up current on the connected load| 12A/8ms (use an external relay
for larger start-up currents).
0-10V Output
Voltage range| 0-10 VDC
Maximum energy use| 6mA
DALI-Output
Voltage range| 9-12 VDC
Maximum energy use| 6mA
Radio receiver
Operating frequency| 2.4…2.483 GHz
Maximum output power| +4 dBm
Operating conditions
Ambient temperature, bring| -20…+50°C (Iut 0 A)
The maximum enclosure temperature, to|
Connections
Cable cross-sectional area, single and multi-stranded| 0.75-1.5 mm²
14-22 AWG
Stripping length| 6-7 mm
Tightening torque| 0.4 Nm/4 Kgf.cm/2.6 Lb-In
Mechanical data
Dimensions| 56.5 x 35.8 x 22.3 mm
Weight| 48 g
IP-protection| IP20 (for indoor use only)
Rating| Built-in class II