VADSBO VD600 Rotary Dimmer Instruction Manual

June 4, 2024
VADSBO

VADSBO logo VD600 Rotary Dimmer
Instruction ManualVADSBO VD600 Rotary Dimmer fig
2

Installation instructions VD600

Warning!
High voltage. Risk of electric shock. The installation should only be carried out by an authorized electrician.
Connection
For LED 0-600VA (450W), 230V halogen, and electronic transformers. Do not use the LED dimmer for fluorescent lamps, fans or toroidal cores.

  1. Stop the current.
  2. Connect the phase to one of the terminal boxes marked with L1 or L2 on the dimmer.
  3. Connect the conductor that continues to the load of the terminal box on the dimmer marked with (see the connection drawing).
  4. In order to use the on/off function (no dimming) to a load – connect the load to the terminal EXT.
  5. The earthed neutral should be directly connected to the load. If it is broken in the equipment, or box, connect with a clamp or another connection.
  6. Install the dimmer (A) in the equipment box. Make sure that no cables are clamped.
  7. If required, adjust the minimum level with the help of the middle regulator in position (E). In case of flickers, adjust exactly with the upper regulator.
  8. Screw the casing (B) tight with the enclosed nut (C ).
  9. Press the knob (D) securely with a single press.

VADSBO VD600 Rotary Dimmer fig

Technical data

Item number| White: V-40V0600-001Y
Black: V-40V0600-002Y
---|---
Voltage| 230V +/- 10% 50Hz
Max current strength| 2,6A
Least load| 0VA
Max load| 600VA (450W)
Casing class| IP20
Size| 87x87x46mm
Mounting depth| 24mm
Weight| 90g
Colour| White: Pure White (RAL9010)
Signal White (RAL9003)
Black: Jet Black (RAL9005)
Graphite Grey (RAL7024)
Short-circuit protection| Yes, self-resetting
Overload protection| Yes, self-resetting
Thermal protection| Yes, self-resetting
Max Ta| 75oc
Operating temperature| -20oc till +40 oc
Power consumption without load| <0,3W

VADSBO VD600 Rotary Dimmer fig 1

NOTE! Keep in mind that depending on the manufacturer, LED, and low- energy sources may consume up to the double-rated output. ****
VADSBO VD600 Rotary Dimmer fig 2

Staircase feature

Follow the instructions for “connection” but replace points 2 and 3 with points 1, 2, and 3 below.

  1. Connect the phase to the terminal box marked with
  2. Connect the outgoing phases (arrow out, arrow out) from the two-way switch to the entry of the dimmer (L1 arrow in, L2 arrow in).
  3. Connect the conductor that connects to the load at the terminal box marked on the dimmer.

VADSBO VD600 Rotary Dimmer fig 3

Dimmer adjustment

Exact adjustment of the least dimmer level for the most common loads.
Procedure: Dim the load to minimum light. Turn the potentiometer clockwise with a screwdriver to set the lowest dimmer level. Stop when you reach a satisfactory level, i.e. when there is no flickering Adjustment of maximum dimming level/flicker when the load is dimmed to a maximum level, for loads that need additional adjustment. Is used for loads, where there is flickering in the maximum dimmed position. Is also used for exact adjustment of the maximum dimmer level.VADSBO VD600 Rotary Dimmer icon 1

Procedure: Dim the load to maximum light. In case of flickering, turn the potentiometer clockwise with a screwdriver so as to reduce the amount of flickering. Stop when you reach a satisfactory level, i.e. when there is no flickering.
When adjusting exactly, turn the potentiometer clockwise with a screwdriver and stop just before the light begins to dim. Stop when you are satisfied.
Activation and adjustment of the boost feature Is used for loads when the light is lit at different speeds (popcorn effect). Is used even for difficult loads when switching on and off, to start them.
Procedure: Dim the load to minimum light. Activate the boost feature by switching the dip switch to ON using a screwdriver. Turn the knob on and off with a 5-second gap to understand the effect of the feature.
Use the potentiometer to adjust the amount of boost until the light starts up to a comfortable level.VADSBO VD600 Rotary Dimmer icon
2

Troubleshooting

Problem Reason Action
The dimmer doenot work The line voltage is noconnected Connect to the line

voltage
The load is not connect| Connect the load
The amount of load is too much| Reduce the amount of load/ Divide the load in groups
The lamp or load is broken| Replace the load
The least dimmer level is set too low| Increase the least dimmer level
The Boost feature is not activated| Activate the boost feature, see the section on the boost feature
The dimmer turns off| The thermal protection is activated| Reduce the load or check the installation environment
It flickers in max position| The MAX potentiometer is incorrectly
set| See the chapter on the maxi- mum dimmer level.
It flickers in the bottom position.| The least dimmer level is set too low| Increase the least dimmer level
The light flashes in the begin- ning before it stabilises| The boost feature is incorrectly set.| Turn off the boost feature, or adjust it exactly, see the
section on boost feature

Installations manual Version 1, 22-05-23
Installation manual Version 1, 22-05-23

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals