ACCORD C40730 XPC Alarm Remote Keypad Instruction Manual
- June 6, 2024
- ACCORD
Table of Contents
- Important:
- LED KEYPAD PROGRAMMING
- PART SET [2]
- Unsetting the System
- Resetting the System
- Testing the System [5]
- Omitting Zones [6]
- Changing Codes [8]
- PROGRAMMING OTHER USER CODES INTO THE SYSTEM
- DELETING USER CODES
- Setting the Date and Time
- Chime Facility [9]
- Viewing the Log [0]
- LCD KEYPAD PROGRAMMING Setting the System
- PART SET
- NIGHT SET
- Unsetting the System
- Resetting the System
- Testing the System
- Omitting Zones
- Changing Codes
- PROGRAMMING OTHER USER CODES INTO THE SYSTEM
- DELETING USER CODES
- Setting the Date and Time
- Chime Facility
- System Indications
- Hot Keys
- Additional Information
- ALARM SYSTEM SETTINGS
- ZONE LOCATION CHART
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER INSTRUCTIONS
Important:
- Ensure all system detectors are clear before proceeding.
- Ensure all windows and doors are secure.
LED KEYPAD PROGRAMMING
Setting the System
FULL SET [1] To FULL SET the system:
- Enter the User Code.
- Press 1 (Full Set).
A constant exit tone will sound. During the exit period, the DAY LED will
flash and the exit tone will become broken as the user passes detectors on the
exit route. The exit tone will become constant when the last detector on the
exit route has been passed. Two confirmation beeps indicate that the system
has been set.
Note: To stop the system from setting during the exit period press Ö. When the
system has set, Ö will no longer function. Press # + 1 (Full Set) to EASY SET
the system, if available.
PART SET [2]
Selected areas will be set using the Part Set function. The engineer will
program which selected areas will be set with user approval, (see System
Settings).
To PART SET the system:
- Enter the User Code.
- Press 2 (Part Set).
A constant exit tone will sound. During the exit period, the DAY LED will
flash and the exit tone will become broken as the user passes detectors on the
exit route. The exit tone will become constant when the last detector on the
exit route has been passed. Two confirmation beeps indicate that the system
has set.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 2 (Part Set) to EASY SET the system, if available
NIGHT SET [3]
Night Set permits the user to set the system in selected areas, whilst others
are unset, e.g. unset in bedrooms whilst set in remaining rooms of the house.
This permits freedom of movement in a secure environment.
To NIGHT SET the system:
- Enter the User Code.
- Press 3 (NIGHT SET).
No exit tone will sound during the exit period, however, the DAY LED will
flash as the user passes detectors on the exit route. Two confirmation beeps
indicate that the system has set.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 3 (Night Set) to EASY SET the system, if available.
Unsetting the System
To UNSET the system:
- Proceed to a keypad via the approved route and enter the User Code.
Resetting the System
To UNSET and RESET the system during or after an Alarm:
Entering a User Code will stop any alarm in progress. The zone LED causing the
initial alarm will then be displayed on the keypad. The User Code may be
entered again to reset the system.
If the panel has been programmed to accept only an Engineer Reset after an
alarm an Engineer Code is required to RESET the system.
A Technistore Reset is required if all the LEDs illuminate simultaneously
followed by a 5 digit series of numbers indicated by the LEDs lighting in
sequence. This code is given to the monitoring station to obtain an anti-code
which can be entered to RESET the system.
Note: If the system does not reset Contact the alarm company.
Testing the System [5]
To TEST the system:
- Enter the User Code.
- Press 5 (TEST).
Note: The outside bell/sounder will ring for 5 seconds and the strobe will
flash until the test is finished. All LEDs on the keypad will light up for 5
seconds. Test each zone individually when the keypad stops scrolling and the
bell/sounder stops
ringing. Activate the zone to verify the display of the zone on the LCD, two
beeps will sound. To exit test mode enter the User Code and wait for two
beeps.
Omitting Zones [6]
To Omit Zones:
- Enter the user code.
- Press 6 (Omit).
- Enter the Zone Number(s) to be isolated.
- Press Ö to finish or wait 5 seconds.
- Set the system
e.g. To omit zones 6, 7 and 8, press 1234 6 678. Zone LED 6, 7, and 8 will
flash.
Press Ö or wait 5 seconds.
To correct a wrong omitted zone:
- Enter the User Code
- Press 6 (Isolate)
- Press Ö or wait for a confirmation beep.
Note: Fire, Silent PA, and PA cannot be isolated.
Unsetting the system will restore normal operation and all zones.
Changing Codes [8]
The system can support up to 8 separate user codes.
MASTER CODE: User 1.
The Master Code (User 1) can be changed:
- Enter Master Code (e.g. 1234).
- Press 8 (Code).
- Press 1 (User 1).
- Enter new User Code (e.g. 5678). Two beeps confirms code acceptance.
PROGRAMMING OTHER USER CODES INTO THE SYSTEM
The Master Code is used to program new User Codes into the system:
- Enter Master Code (e.g. 5678).
- Press 8 (Code).
- Press 2 (User 2).
- Enter User 2 Code (e.g. 4321).
Users can program their own new User Codes into the system:
- Enter User Code (e.g. 4321).
- Press 8 (Code).
- Press 2 (User 2).
- Enter new User 2 Code (9876).
DELETING USER CODES
Any user may delete their own code by entering their CODE + 8 + USER No + Ö:
- Enter User 2 Code (e.g. 9876).
- Press 8 (Code).
- Press 2 (User 2).
- Press Ö.
Note: The MASTER CODE can delete any USER CODE.
“DURESS – User Code 8 may have been reserved for a DURESS CODE. This type of
code can perform all normal system functions but will send a silent DURESS
Signal to your monitoring station”
Setting the Date and Time
The system contains a clock that is used to record the DATE AND TIME of each
event as it occurs.
To Set the clock:
- Enter User Code.
- Press # + 0.
- Enter ddmmyyhhmm (day, month, year, hour, minute). Two confirmation beeps acknowledge correct entry.
Note: Users cannot view time
Chime Facility [9]
Any zone can be programmed to give a CHIME (2 beeps from the keypad and 2
beeps from the internal sounder) when operating the zone.
To program a zone to Chime:
- Enter User Code
- Press 9 (Chime)
- Enter zone for Chime.
- Press Ö to finish or wait for confirmation beep.
To disable the chime facility on all zones:
- Enter User Code
- Press 9 (Chime) and press Ö
Viewing the Log [0]
The User can VIEW the last 16 alarm zones:
- Enter User Code.
- Press 0.
The most recent alarm zones are displayed first, indicated by the zone LED and
a
single beep.
LCD KEYPAD PROGRAMMING Setting the System
FULL SET
To FULL SET the system:
- Enter the User Code.
- Press 1/ (Full Set).
A constant exit tone will sound. During the exit period, the DAY LCD symbol
will flash and the exit tone will become broken as the user passes detectors
on the exit route. The exit tone will become constant when the last detector
on the exit route has been passed. Two confirmation beeps indicate that the
system has set.
Note: To stop the system from setting during the exit period press Ö. When the
system has set, Ö will no longer function. Press # + 1 / (Full
Set) to EASY SET the system, if available.
PART SET
Selected areas will set using the Part Set function. The engineer will program
which selected areas will be set with user approval, (see System Settings).
To PART SET the system:
- Enter the User Code.
- Press 2/ (Part Set).
A constant exit tone will sound. During the exit period, the DAY LCD symbol
will flash and the exit tone will become broken as the user passes detectors
on the exit route. The exit tone will become constant when the last detector
on the exit route has been passed. Two confirmation beeps indicate that the
system has set
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 2/ (Part Set) to EASY SET the system, if available.
NIGHT SET
Night Set permits the user to set the system in selected areas, whilst others
are unset, e.g. unset in bedrooms whilst set in remaining rooms of the house.
This permits freedom of movement in a secure environment.
To NIGHT SET the system:
- Enter the User Code.
- Press 3/ (NIGHT SET).
During the exit period, the DAY LCD symbol will flash. Two confirmation beeps
indicate that the system has been set.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 3/ (Night Set) to EASY SET the system, if available.
Unsetting the System
To UNSET the system:
- Proceed to a keypad via the approved route and enter the User Code.
Resetting the System
To UNSET and RESET the system during or after an alarm:
Entering a User Code will stop any alarm in progress. The zone number causing
the initial alarm will then be displayed on the LCD keypad. The User Code may
be entered again to RESET the system.
If the panel has been programmed to accept only an Engineer Reset after an
alarm an Engineer Code is required to RESET the system.
If the panel has been programmed to accept only a Technistore Reset the keypad
will flash the cE symbol followed by the activated zone number. The cE symbol
will then flash again followed by a five-digit code which should be given to
the monitoring station who will then issue an antipode. This antipode will
RESET the system when entered on the keypad.
Testing the System
To TEST the system:
- Enter the User Code.
- Press 5/ (TEST).
The outside bell/sounder will ring for 5 seconds and the strobe will flash
until the test is finished. The keypad LCD scrolls through zone numbers 1-8
for 5 seconds.
Note: Test each zone individually when the keypad stops scrolling and the
bell/sounder stops ringing. Activate the zone to verify the display of the
zone on the LCD, two beeps will sound. To exit test mode enter the User Code
and wait for two beeps.
Omitting Zones
To OMIT Zones:
1. Enter the user code.
2. Press 6/ (OMIT).
3. Enter the Zone Number(s) to be omitted.
4. Press Ö to finish or wait 5 seconds for confirmation beep.
5. Set the system
e.g. To omit zones 6, 7, and 8, press 1234 6/ 678. Zone No. 6, 7, and 8 will
flash. Press Ö or wait 5 seconds for confirmation.
To correct a wrong omitted zone:
1. Enter the User Code
2. Press 6/ (Omit)
3. Press Ö or wait for a confirmation beep.
Note: Fire, Silent PA, and PA cannot be omitted.
Unsetting the system will restore normal operation and all zones.
Changing Codes
The system can support up to 8 separate user codes.
MASTER CODE: User 1.
The Master Code (User 1) can be changed:
- Enter Master Code (e.g. 1234)
- Press 8/ (CODE)
- Press 1 (User 1)
- Enter new User Code (e.g. 5678). Two beeps confirms code acceptance.
PROGRAMMING OTHER USER CODES INTO THE SYSTEM
The Master Code is used to program new User Codes into the system:
- Enter Master Code (e.g. 5678).
- Press 8/ (Code).
- Press 2 (User 2).
- Enter User 2 Code (e.g. 4321).
Users can program their own new User Codes into the system:
- Enter User Code (e.g. 4321).
- Press 8/ (Code).
- Press 2 (User 2).
- Enter new User 2 Code (9876).
DELETING USER CODES
Any user may delete their own code by entering their CODE + 8 + USER No + Ö:
- Enter User 2 Code (e.g. 9876).
- Press 8/ (Code).
- Press 2 (User 2).
- Press Ö.
Note: The MASTER CODE can delete any USER CODE.
DURESS – User Code 8/ may have been reserved for a DURESS CODE. This type of
code can perform all normal system functions but will send a silent
DURESS Signal to your monitoring station
Setting the Date and Time
The system contains a clock that is used to record the DATE AND TIME of each
event as it occurs.
To Set the clock:
- Enter User Code.
- Press # + 0.
- Enter ddmmyyhhmm (day, month, year, hour, minute). Two confirmation beeps acknowledge correct entry.
Chime Facility
Any zone can be programmed to give a CHIME (2 beeps from the keypad and 2
beeps from the internal sounder) when operating the zone.
To program a zone to Chime:
- Enter User Code
- Press 9/ (Chime)
- Enter zone number for Chime.
- Press Ö to finish or wait for confirmation beep.
To disable the Chime on all zones enter User Code, press 9 then Ö.
The Chime function cannot be disabled on individual zones. Entering and
exiting programming mode will delete all Chimes.
Viewing the Log
The User can VIEW the last 16 alarm zones:
- Enter User Code.
- Press 0.
The most recent alarm zones are displayed first on the LCD with a single beep.
System Indications
FUNCTIONS
| LCD KEYPAD|
LED KEYPAD
---|---|---
DAY MODE
FULL SET
PART SET
NIGHT SET
ZONE 9 TAMPER
ZONAL TAMPER
ALARM/TEST
LINE FAULT
COMMS FAIL
LOCKOUT
PA HOTKEY
FIRE HOTKEY
ASSIST HOTKEY
OMIT
BATT. MISSING
BATTERY LOW
MAINS FAIL
ENG. MODE| | (solid)
(flashing)
(flashing)
(flashing)
(flashing)
(solid) + zone no.
Zone no.(solid)
(solid)
(flashing)
(solid)
(solid)
(solid)
(solid)
(solid) + zone no.
(solid) X flashing
(solid) X flashing
(flashing)
(flashing)| DAY LED (solid)
DAY LED (flashing)
DAY LED (flashing)
DAY LED (flashing)
TAMPER LED (solid)
TAMPER LED + ZONE LED (flashing)
ZONE LED (solid)
TELEPHONE LED (solid)
TELEPHONE LED (flashing)
All LED’s (flashing)
All LED’s (solid)
All LED’s (flashing in sequence)
All LED’s (flashing alternate)
ZONE LED (flashing)
BAT LED (solid)
BAT LED (solid)
POWER LED OFF
POWER LED (flashing)
Hot Keys
Hot Key | Type | Keypad N | LCD Display |
---|---|---|---|
1 | Assistance | 4+6 | |
2 | Fire | 7+9 | |
3 | Panic | *+# |
Hotkeys are convenient and specific for the alarms specified above.
e.g. To trigger a fire alarm.
- Press 7 + 9.
- The fire alarm will sound (pulse tone), all LEDs ON/ .
- Enter User Code to exit alarm mode.
Additional Information
Entry Time :
Exit Time :
Easy SET : Yes / No
Alarm Company Telephone Number :
Daytime :
Night-time :
Hotkey Enabled: Yes / No
ALARM SYSTEM SETTINGS
X: Zones that are active in each set mode.
ZONE LOCATION CHART
ZONE | LOCATION | RF (ON/OFF) |
---|---|---|
1 | ||
2 | ||
3 | ||
4 | ||
5 | ||
6 | ||
7 | ||
8 |
IU1-1230 Issue B
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>