Skindfense H3-Plus Intelligent Contactless Hand Sanitizer User Manual

June 6, 2024
Skindfense

Skindfense H3-Plus Intelligent Contactless Hand Sanitizer User Manual
Skindfense H3-Plus Intelligent Contactless Hand
Sanitizer

Introduction

Introduction
Introduction

State Description

  • “Lo”
    The temperature is below 89.6˚F The red light flashes and announces “Please re-test”
    State Description

  • “HI”
    The temperature is higher than 107.6˚F. The red light flashes and announces “Please re-test”
    State Description

  • “Abnormal temperature”
    The red light flashes continuously with an alarm sound
    State Description

  • “Room temperature”
    The green light flashes and it announces “normal temperature”
    State Description

Operation Instruction

  1. Switch and Reset:
    Press the “ON/OFF/Menu” button, the machine will start up
    Press and hold the “Menu” button for 2 seconds, the machine will shut down.
    Press and hold the “ON/OFF/Menu” button for 6 seconds until “RST” is displayed, then reset to the factory default settings.

  2. Historical temperature query:
    Use the “Left” and “Right” keys to view historical temperature data. The H3 Plus supports up to 118 readings to review.
    Display the serial number of the review temperature first, and then display the temperature corresponding to the serial number
    Operation Instruction

  3. Clear historical data:
    After viewing the historical temperature, press and HOLD the “Left” or “Right” button for 2 seconds. The screen will display “CLr”. When the 3 horizontal bars are displayed the data is cleared.
    Press the ON/OFF/Menu” button or wait 10 seconds to automatically exit.
    Operation Instruction

  4. Exit menu settings:

  5. Press and hold the ON/OFF/Menu” button

  6. Wait 10 seconds to automatically exit.

  7. Temperature measurement:
    Sensor distance is 2 to 4 inches
    Operation Instruction

  1. Language setting:
    Quickly press the “Menu” button ONCE to enter the language setting. Selecting the “Left” and “Right” buttons will switch the language. A voice will broadcast the selected language: CH/CH1/CH2/CH3: Chinese. EN: English. IT: Italian. HR: Korean. SP: Spanish. JP/JP1: Japanese. GE: German: PO: Portuguese. FR: French. RU: Russian. AR: Arabic. IN: Hindi. HO: Dutch. TL: Thai. PL: Polish. DI: Buzzer sound “di”
    Menu Setting

  2. Temperature unit setting:
    Quickly press the “Menu” button TWICE to enter the temperature unit setting. Selecting the “Left” and “Right” buttons will switch between Celsius and Fahrenheit.
    C: Celsius. F: Fahrenheit
    Menu Setting Menu
Setting

  3. Volume setting:
    Quickly press the “Menu” button THREE TIMES to enter the volume setting. The default setting is V02.
    Use the “Left” and “Right” buttons to adjust the volume. VoO is silent, Vo5 is Maximum.
    Menu Setting

  4. Mode setting:
    Quickly press the “Menu” button FOUR TIMES to enter the measurement mode.
    Selecting the “Left” and “Right” buttons will switch the mode settings.
    Body Mode
    Menu Setting
    Surface Mode
    Menu Setting
    Counting Mode
    Menu Setting

  5. Alarm temperature setting:
    Quickly press the “Menu” button FIVE TIMES to enter the alarm temperature mode. The “Left” or “Right” keys can switch between the alarm temperature 36.0-38.0˚C. The default is 37.5˚C. The temperature alarm is only valid in “Body” mode.
    Menu Setting

  6. Automatic shutdown setting:
    Quickly press the “Menu” button SIX TIMES to enter the shutdown setting. The “Left” or “Right” keys can switch between 12 hours or not automatic shutdown.
    The default A1 is 12 hours to shut down automatically
    A1: Automatic shutdown 12 hours
    Menu Setting
    A0: No automatic shutdown
    Menu Setting

  7. Ultra-low temperature setting:
    Quickly press the “Menu” button SEVEN TIMES, the “Left” and “Right” buttons switch “nor/LO/32/0”. The default is “nor”
    Regular Mode
    Supports measurement in low temperature environment
    Menu Setting
    When the body temperature is lower than 32.0˚C. Display 32.0 and green light, and announce “normal temperature.”
    Menu Setting
    When the body temperature is lower than 32.0˚C. Display LO and green light, and announce “Please retest.”
    Menu Setting

  8. Sound effects setting:
    Quickly press the “Menu” button EIGHT TIMES, the “Left” and “Right” buttons switch the sound effects between “D1” or “DO” before voice broadcast.. The default is “D1” and gives the “Di” sound.
    DO: Sound effect: “ding-
    Menu Setting
    D1: Sound effect: “Di”
    Menu Setting

  9. High temperature alarm setting:
    Quickly press the “Menu” button NINE TIMES, to set the high temperature alarm sound: “R1” or “RO.” The default is “R1” which is an alarm sound
    R1: Alarm tone
    Menu Setting
    R2: 5 second “DiDi” sound
    Menu Setting

Installation Method

Battery installation:

Open the battery cover, install batteries according to the proper polarity
Installation Method

Tips:

  1. The user has the responsibility to ensure the proper environment for the equipment to function properly.
  2. When changing the operating environment, the equipment must be allowed to acclimate for at least 30 minutes.
  3. Glasses and hair can affect infrared. When measuring, please take off your glasses and align your forehead with the sensor head.
  4. Please avoid direct sunlight when using the H3Plus outdoors.
  5. Keep away from air conditioning and fans, etc.
  6. In order to preserve power, the machine will automatically shut down after 12 hours of no operation.
  7. Please use proper batteries with safety certification, and install them correctly according to the correct polarity. Non-certified batteries or reversing the polarity will damage the product.
  8. Replace the battery, or recharge the Lithium-ion battery when the power is low.
  9. Use the H3 Plus indoors in cold weather, and ensure the forehead is close to the device.

Specifications

Screen

|

Digital Display

---|---

Accuracy

| +/- 0.2 Degrees (after being placed in a working environment for 30 minutes
Response Time|

0.5 Seconds

Alarm Function

| Automatic alarm is abnormal, flashing + sound alarm for about 5 seconds
Automatic Measurement|

Measuring Distance 2-4 inches

Adaptive Power

| USB power supply and battery power supply 18650 Lithium-ion or (3) AA batteries, automatically switching
Input/Interface|

Micro USB

Infrared Measuring Range

| 32˚F – 122˚F
Environmental Temperature|

50˚F – 104˚F

Weight

| 6.2 oz.
Dimensions|

5.7 x 3.75 x 3.15 inches

Counting Range

| 0-1999
Data Storage|

Supports 118 sets of measurement data storage, review and clearing

Skindfense LOGO

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Skindfense User Manuals

Related Manuals