BM1390GLV-EVK-001is an evaluation board for BM1390GLV, which is a ROHMpressure sensor. This User’s Guide is about how to useBM1390GLVEVK-001 together with ROHM Shield for Arduino*
Preparation
BM1390GLV-EVK-0011………..pc
Shield for Arduino…………………. 1pc
Arduino Uno……………… 1pc
USB Cable……………. 1pc
Computer Installed Arduino IDE…………… 1pc
– Requirement: Arduino IDE 1.8.13 or higher
– Please get Arduino IDE from the link below: http://www.arduino.cc/
Setting
Figure 1. Connection of Arduino Uno and Shield for Arduino
-
Connect Arduino Uno and Shield for Arduino. (Figure 1)
-
Connect BM1390GLV-EVK-001 to the socket of I2C area on Shield for Arduino. (Figure 2)
-
Set the voltage of Shield for Arduino to 1.8V or 3.0V. (Figure 2)
-
Connect Arduino Uno to Computer using a USB cable.
-
Get BM1390GLV Software 2 from the link below: https://www.rohm.com/sensor-shield-support 2 The software is subject to change without notice.
-
Launch Arduino IDE.
-
Select [Sketch] -> [Include Library] -> [Add.ZIP library…], then BM1390GLV Software. (Figure 3)
-
Select [File] -> [Examples] -> [Examples from custom libraries], then BM1390GLV Software.
Measurement
-
Select [Tools]. Set Board to “Arduino Uno” and Port to “COMxx (Arduino Uno)” 3. (Figure 4) 3 COM number is different in each environment.
-
Click the write button and wait for the message “Done uploading.”. (Figure 5)
-
Select [Tools] -> [Serial Monitor]. (Figure 6)
-
Set the baud rate to 115200 baud and check log of the Serial Monitor. (Figure 7)
*Board Information 4*
4 Board Information is subject to change without notice.
- Digital Communication Interface: I2C
- Slave Address: 0x5D
- Selectable Voltage of Shield for Arduino: 1.8V, 3V
- Supply Voltage for VDD: 1.7V – 3.6V
- Operating Temperature Range: -40 – +85
Note: BM1390GLV-EVK-001 is non-waterproof.
Table 1. Parts Information
Parts Number | Description |
---|---|
U1 | IC: BM1390GLV |
C1 | Bypass capacitor for VDD: 0.1uF |
C2 | Bypass capacitor for VREG: 0.22uF |
R1 | Pull-up register for SDA: N.M. |
R2 | Pull-up register for SCL: N.M. |
JP1 | Pull-up register for DRI: N.M. |
CN1 | Pin header: 2.54 mm pitch, 00.8 |
*5 N.M. = No Mount
Notes
- The information contained herein is subject to change without notice.
- Before you use our Products, please contact our sales representative and verify the latest specifications :
- Although ROHM is continuously working to improve product reliability and quality, semiconductors can break down and malfunction due to various factors. Therefore, in order to prevent personal injury or fire arising from failure, please take safety measures such as complying with the derating characteristics, implementing redundant and fire prevention designs, and utilizing backups and fail-safe procedures. ROHM shall have no responsibility for any damages arising out of the use of our Products beyond the rating specified by ROHM.
- Examples of application circuits, circuit constants and any other information contained herein are provided only to illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production.
- The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM or any other parties. ROHM shall have no responsibility whatsoever for any dispute arising out of the use of such technical information.
- The Products specified in this document are not designed to be radiation tolerant.
- For use of our Products in applications requiring a high degree of reliability (as exemplified below), please contact and consult with a ROHM representative: transportation equipment (i.e. cars, ships, trains), primary communication equipment, traffic lights, fire/crime prevention, safety equipment, medical systems, servers, solar cells, and power transmission systems.
- Do not use our Products in applications requiring extremely high reliability, such as aerospace equipment, nuclear power control systems, and submarine repeaters.
- ROHM shall have no responsibility for any damages or injury arising from non-compliance with the recommended usage conditions and specifications contained herein.
- ROHM has used reasonable care to ensure the accuracy of the information contained in this document. However, ROHM does not warrants that such information is error-free, and ROHM shall have no responsibility for any damages arising from any inaccuracy or misprint of such information.
- Please use the Products in accordance with any applicable environmental laws and regulations, such as the RoHS Directive. For more details, including RoHS compatibility, please contact a ROHM sales office. ROHM shall have no responsibility for any damages or losses resulting from non-compliance with any applicable laws or regulations.
- When providing our Products and technologies contained in this document to other countries, you must abide by the procedures and provisions stipulated in all applicable export laws and regulations, including without limitation the US Export Administration Regulations and the Foreign Exchange and Foreign Trade Act.
- This document, in part or in whole, may not be reprinted or reproduced without the prior consent of ROHM.
Thank you for your access to ROHM product information. More detail product
informations and catalogs are available, please contact us.
ROHM Customer Support System http://www.rohm.com/contact/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>