FIRSTCO T200 Autospeed 24V Thermostat Instructions

June 6, 2024
FIRSTCO

FIRSTCO T200 Autospeed 24V Thermostat

INSTRUCTIONS

OPTIONAL ACCESSORIES (FIELD INSTALLED)

DESCRIPTION| PART #| DIMENSIONS

WALL PANEL (1)

| 9PWUC01L (4-10)| 43-3/8 X 25-5/8

(Outside Frame)

| 40-3/8 X 22-5/8

(Inside Frame)

9PWUC02L (12)| 46-3/8 X 25-5/8

(Outside Frame)

| 43-3/8 X 22-5/8

(Inside Frame)

HANGER BRKT. SET| 90PK3| 1-1/2 X 22-1/8| —
RETURN AIR COVER| 90PK4 (4-10)| 19-13/16 X 22| —
90PK5 (12)| 21-5/8 X 22| —
CONDENSATE OVERFLOW SWITCH|

SS3

|

|

WALL THERMOSTAT

3-SPD., MANUAL CHANGEOVER

|

T420

(120/240/277)

|

|

WALL THERMOSTAT 3-SPD., AUTO CHANGEOVER|

T421

(120/240/277)

|

|

24V WALL THERMOSTAT

3-SPD., MANUAL CHANGEOVER (AUTOSPEED 24V)

|

T200

(24V)

|

|

24V WALL THERMOSTAT 3-SPD., AUTO CHANGEOVER

(AUTOSPEED 24V

|

T201

(24V)

|

|

OPTIONAL VALVE CLUSTERS (Factory installed)|
PART #| DESCRIPTION
VALVE CLUS- TER:
9VCWNVM| No valves, stub kit only
9VCW2BVM| 2 hand valves
9VCW22BM| 2-way, valve body, 2 hand valves
9VCW23BM| 3-way, valve body, 2 hand valves
POWER HEAD:
911-111| 24V

NOTES:
All models are available with or without factory installed valve clusters. Above are “standard” 2-way and 3-way valve clusters.. Contact the factory for other options such as circuit setters, strainers, auto-flow valves, etc.

In keeping with its policy of continuous progress and product improvement, First Operations reserves the right to make changes without notice. Maintenance for all First Co. products is available under “Product Maintenance” at www.firstco.com

Accurate, Efficient, and Quiet Fan Coil Operation

The new Autospeed 24V™ thermostat (part’s # T200 and T201) provides 24V AC single stage temperature control of 2 pipe and 4 pipe fan coil applications. The T200/T201 thermostat offers maximum comfort and efficiency by automatically selecting the appropri-ate High, Medium, or Low fan speed, depending on room temperature and thermostat temperature setting. This automatic fan speed control not only brings the room temperature to the desired set point quickly, it maintains the room temperature with the most efficient fan speed selection. Once the desired room tempera-ture is achieved the fan coil operates on low speed for extremely quiet operation. The fan coil control board (which is factory installed in all CW units) is a circuit board that provides control of a 3-speed line voltage fan motor. The control board allows the thermostat to control the fan motor even though, by itself, the ther-mostat does not have the amperage capability nor the voltage rating capability to control the fan motor.

T200/T201 Thermostat Features

  • Compatible with 2 pipe and 4 pipe fan coils: Series HBC/PHBC/RHBC/CHBC,
    MB/MB-HW, HYB/PHYB, and CW/CH-HW/CWE

  • Cycle fan or continuous fan operation

  • T200-Manual Heat / Cool changeover switch

  • T201-Automatic Heat / Cool changeover switch

  • Large LED digital display

  • Allows less expensive 24V control wiring from the fan coil to the thermostat, rather than larger, more expensive line voltage wiring.

  • 3-speed fan operation, with speed indicator lights

  • Fan speed determination:

    • If room temperature is 4 degrees (F.) off thermostat set point, fan will operate on High speed.
    • If 3 degrees off set point, fan will operate on Medium speed.
    • If within 2 degrees of set point, fan will operate on Low speed.
  • One or 3 hour Auto override – Fan speed defaults to “Auto” mode after 1 hour if the user manually changes it to a particular fan speed.

  • Temperature set range: 64-88 degrees F.

  • Adjustable high and low temperature set points

  • Selectable Fahrenheit / Centigrade display

  • Power switch turns system off/on

  • Requires 7-wire 24V thermostat wire

  • No batteries required

  • Set points are permanently retained in memory in case of power interruption

  • Simple operation

  • Mercury Free

  • Wall plate included

DISPLAY CODES

DISPLAY| STEADY| FLASHING
P1| Auto fan timer – 1 hour (default)| Auto fan timer – 3 hour
P2| Continuous fan (default)| Cycled fan
P3| oF (default)| oC
P4| Cycled fan standard| Cycled fan overdrive (default)
P5| Low temo limit 64 oF (default)| Low temp limit 67 oF
P6| Hi temp limit 88 oF (default)| Hi temp limit 84 oF

Read User Manual Online (PDF format)