Tewaycell TW-WM48200-HWB Wall Mounted Type ESS Battery Instruction Manual
- June 1, 2024
- Tewaycell
Table of Contents
- Tewaycell TW-WM48200-HWB Wall Mounted Type ESS Battery
- Product Information
- Product Usage Instructions
- Feature
- Application
- Safety Tips
- Product Description
- Technical Specifications
- BMS characteristics
- Description of parallel connection
- Operating instructions
- Product list and tools
- Instruction manual
- Application
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Tewaycell TW-WM48200-HWB Wall Mounted Type ESS Battery
Product Information
Specifications:
- Product Name: XYZ
- Model Number: 12345
- Colour: Black
- Material: Plastic
- Dimensions: 10 x 5 x 3 inches
Product Usage Instructions
Setup and Installation:
Follow these steps to set up the product:
- Unbox the product and check for all components.
- Connect the cables as per the diagram in the manual.
- Power on the device and follow the on-screen instructions for initial setup.
Operation:
To operate the product:
- Use the power button to turn the device on/off.
- Navigate through the menu using the provided controls.
- Refer to the user manual for specific functions and features.
Maintenance:
Regular maintenance will ensure optimal performance:
- Clean the product surface with a soft cloth.
- Avoid exposure to extreme temperatures or moisture.
Frequently Asked Questions (FAQ):
-
Q: How do I troubleshoot if the product does not turn on?
A: Check the power source and ensure all connections are secure. If the issue persists, contact customer support. -
Q: Can I use this product outdoors?
A: It is recommended to use the product indoors to avoid damage from environmental factors. -
Q: How often should I replace the batteries?
A: Replace the batteries when you notice a decrease in performance or when the low battery indicator lights up.
Wall-mounted Type ESS Battery
- TW-WM51200-HWB TW-WM48200-HWB
- TW-WM51100-HWB TW-WM48150-HWB
- TW-WM51150-HWB TW-WM48100-HWB
Feature
- Using lithium iron phosphate core technology, higher ety, 80% DOD charging and discharging under standard conditions, more than 6000 cycles.
- High-integrated analog front end, isolated power circuit.
- Integrated serial port IC, high voltage accuracy (≤ 20 mV), high current accuracy (≤2% @ FS)
- 4-way battery temperature detection (≤ 2 C), SOC estimation function, SOH estimation function.
- Short circuit protection function, adjustable overcurrent protection, multiple sleep and wake-up modes, and low power consumption.
- Dual RS485 communication, parameter adjustable setting, buzzer alarm function, LED status indication function, charging equalization function.
- Temperature range of battery: -20-60°C.
- Support parallel (up to 15 groups) application expansion.
Application
- Standby power supply and household energy storage.
- Solar and wind energy systems.
Safety Tips
Preface
Thanks for choosing Topway New Energy power wall battery. To make you better
use and maintain this product, please read the user manual carefully before
use.
The features of this product are as follows:
- Adopt brand new lithium iron phosphate cell; Higher security; In the standard state, 80% DOD charge-discharge >6000 times cycle;
- Highly integrated analog front end; Isolating power supply circuit;
- Integrated serial port IC, high voltage accuracy (≤20mV), high current accuracy (≤2%@FS);
- Four-channel battery temperature detection (≤2°C), SOC estimation function, SOH estimation function;
- Short-circuit protection function, adjustable overcurrent protection, a variety of sleep and wake modes, low power consumption;
- Dual-port RS485 communication, parameter adjustable setting, buzzer alarm function, LED status indicator function, with charge balance power;
- Wide temperature range: -20°C~60°C ;
- Parallel connection (up to 15 groups) application expansion is supported, but serial connection is not recommended.
Safety disclaimer
When installing, using and maintaining this product, users must read this
chapter carefully and follow the safety precautions required in this chapter.
Any injuries and losses caused by illegal operations are not related to our
company.
NOTE:
It is strictly forbidden to dismantle the case if Non-professionals and no
warranty service will be provided after.
Description of safety matters
- Keep the battery out of the reach of children and babies;
- Do not put the battery in the oven or other similar equipment;
- Do not remove the product label;
- Do not try to open the battery pack;
- Do not be exposed to the environment above 60°C(300F);
- Do not short-circuit the positive and negative terminals of the battery with wires or other metal objects. Do not transport or store batteries with metal objects;
- Do not expose the battery to direct heat or flame. Do not use or store batteries near fire or high temperatures;
- Do not immerse the battery in water, salt water or any other liquid or make it wet;
- Do not pierce the battery with any sharp object, knock it with a hammer or similar device, step on it, fall it or get strong vibration;
- Do not use the battery if it is damaged or deformed;
- If the battery produces odour, smoke or abnormal heat, please stop using it immediately;
- If the battery liquid leaks and comes into contact with your eyes, please don’t rub your eyes, and immediately rinse them with plenty of water before seeking medical assistance.
Product Description
Product Dimension
Product Details
Electrical schematic diagram
Technical Specifications
Table 1 Technical specification table
BMS characteristics
Instructions for LED lights
Four green capacity indicators, a red alarm indicator, a green running indicator and a switch indicator.
SOC capacity indicator
Table 2 SOC indicator status table
Status indicator
Table 3 Status indicator status table
Table 4 LED flashing description
Boot and sleep mode
Sleep mode: the battery will be in sleep mode if any of the following
conditions are met
-
The battery or battery pack over-discharge protection lasts for 30 seconds and is not released.
-
Press the power on / off button for 3 seconds and release.
-
The minimum voltage of the battery is lower than the “sleep voltage” setting in the setting, without charging and discharging.
-
Standby for more than 24 hours without charging and discharging.
-
Switch to the upper computer for sleep manually.
Wake up: the battery will exit sleep mode if any of the following conditions are met -
Charger is plugged in; The charger voltage is greater than 48V.
-
Press the power on / off button for 3 seconds and release.
-
Plug in the communication cable and open the upper computer software (not available if it is under over-discharge protection).
Note:
If over-discharge protection is enabled, the battery will be in sleep mode.
The battery will wake up automatically every 4 hours and turn on the
charge/discharge MOS. If charging is available, the battery will be charged,
otherwise, it will return to sleep mode. If it has been awakened 10 times but
cannot be charged, the battery will not wake up again automatically.
Communication Area
- RS232: BMS can communicate with the upper computer through the RS 232 interface, to monitor various information about the battery, including battery voltage, current, temperature, status battery production information, etc. the default baud rate is 9600bps.
- RS485: with a dual RS485 interface, you can view the information of the pack. The default baud rate is 9600bps. If it is necessary to communicate with the monitoring equipment through RS485, the monitoring equipment is used as the host, polling data according to the address, and the address setting range is 1 ~ 15.
- CAN: CAN communication, baud rate 9600bps.
- RS485 and CAN: The user can communicate with the inverter through these two interfaces.
- RS485 add RS232: The users can connect to the computer through these two interfaces.
- DCT: Dry contact interface.
- Rst: reset button.
- ADS: dial switch
- Interface diagram
- Definition of electrical interface
Table 1RS485 and CAN Interface
Table 2 Parallel communication port
Description of parallel connection
Parallel Connection Diagram
If parallel batteries are required, connect the wires according to the
diagram, with maximum support for 15 batteries in parallel.
Communication line parallel diagram
The signal line connected to the inverter should use an RS485 communication
line or CAN communication line. If it is necessary to use batteries in
parallel:
- R$485 cable shall be used to connect the parallel communication port. Refer to the communication line parallel diagram.
- The address of the battery needs to be set. Refer to the dial switch setting table for address setting.
Table 3 The Dial Switch Setting Table
Operating instructions
Operating instructions of the display screen
Introduction of LCD Display
Button Description:
- MENU: enter the management system.
- ENTER: enter the submenu.
- DOWN: Move the cursor down or to the next page.
- ESC: returns to the previous one
Boot screen
Battery protection status:
- Overvoltage: OV
- Low voltage: LV
- Overtemperature: Oft
- Low temperature: IT
- Over-current: OC
- Short circuit: SC
Note: when the battery is protected, the corresponding protection status will be displayed; otherwise, the protection status will not be displayed as the protection state.
-
Press “MENU” to enter the main menu
Note: indicates that there is a submenu. Press” enter” to enter the submenu -
Move the cursor to Analog info and press enter
- Move the cursor to “temperature” and press “enter” to check the battery temperature information, then press “down” to turn the page.
- Move the cursor to “cell voltage” and press “enter” to check the battery voltage information, then press “down” to turn the page
- Move the cursor to “CellCapacity” and press Enter to check the battery capacity information
-
Move the cursor to “BMS Status”, press Enter to check the battery status, and press “ ” to turn the page
- Move the cursor to “Record”, then press “Enter” to check the battery alarm information, then press “DOWN” to turn the page.
- Move the cursor to “BMS Status”, then press “Enter” to check the battery protection information, and then press “DOWN” to turn the page.
- Move the cursor to “Para Setting” and press “Enter” to check the gyroscope information, then press” ” to turn the page.
-
Move the cursor to “Sys Setting”, then press Enter to check the version information, and then press “ ” to turn the page.
-
Hibernation and activation functions.
After 1 minute of button-free operation in normal operation, the display will turn off (backlight only), and pressing any button while the screen is off will allow the screen to light up and function normally.
Product list and tools
Product packing lists
Home Energy storage system series power supply has been strictly inspected
before delivery, but may be damaged in transit, therefore, after unpacking the
box, please check whether the following items are complete, confirm the model,
capacity, input voltage and output voltage, and whether the specified content
when ordering; If anything abnormal or inconsistent occurs, please contact the
distributor as soon as possible.
Prepared tools and instruments
Instruction manual
- Use a hammer drill to drill 9 Φ12 through holes in the wall. The depth of each hole must be at least 60mm.
- Install the outer hanging plate on the wall and tighten it with 9pcs M8*50 Expansion screw.
- Hang 6pcs screws on the rear of the battery, attach the battery to the external mounting plate, and tighten the screws.
- Plug the plug of the positive connector onto the positive pole of the battery, and then plug the plug of the negative connector into the negative pole of the battery. The other end is connected to the inverter
Application
- Add: Building A, Xinida Industrial Park, Junzibu Village, Guanlan Stree, Longhua District, Shenzhen, Guangdong
- TEL: 0755-23225527
- FAX: 0755-23225537
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>