aruba R2X11A Instant On AP17 Access Point Installation Guide

June 6, 2024
aruba

aruba LOGO

aruba R2X11A Instant On AP17 Access Point

aruba R2X11A Instant On AP17 Access Point

The Aruba Instant On AP17 access points support IEEE 802.11ac standards for high-performance WLAN, and are equipped with two radios, which provide network access and monitor the network simultaneously. Multiple-in, Multiple-out (MIMO) technology allows these access points to deliver high-performance 802.11n 2.4 GHz and 802.11ac 5 GHz functionality, while also supporting 802.11a/b/g wireless services.

Package Contents

  •  1 x AP17 access point
  •  1 x Wall mount bracket (solid surface)
  •  1 x Cable gland
  •  1 x Copper lug
  •  1 x M4x6 screw
  •  1 x M6x45 screw

NOTE:
Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed.

Hardware Overview

Figure 1 AP17 Access Point

aruba R2X11A Instant On AP17 Access Point FIG 1 LED
The AP17 access point is equipped with a LED that indicates the system status of the device.
Table 1 AP17 Access Point LED Status

LED Color/State Meaning
System LED No Lights Device has no power
Blinking Green Device is starting
Alternating Green/Amber Device is ready for setup
Solid Green Device is ready
Solid Amber Device has detected a problem
Solid Red Device has an issue- immediate action required

Reset Button
The reset button located on the bottom of the device can be used to reset the access point to factory default settings or turn off/on the LED display.
There are two ways to reset the access point to factory default settings:

Reset the AP during normal operation
Press and hold down the reset button using a small, narrow object such as a paper clip for more than 10 seconds during normal operation.

Reset the AP while powering up

  •  Press and hold down the reset button using a small, narrow object such as a paper clip while the access point is not powered on.
  •  Connect the power supply to the access point while the reset button is being held down.
  •  Release the reset button on the access point after 15 seconds.

To turn off/on the LED display, press and release the reset button using a small, narrow object, such as a paperclip for less than 10 seconds during normal operation of the access point.

Ethernet Ports
The AP17 access point is equipped with one 10/100/1000Base-T auto-sensing, MDI/MDX Ethernet port (E0) for wired network connectivity. This port supports IEEE 802.3af Power over Ethernet (PoE), accepting 48Vdc
(nominal) as a standard defined Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE midspan injector, or network infrastructure that supports PoE.

The port has an RJ-45 female connectors with the pin-out shown in Figure 2.
aruba R2X11A Instant On AP17 Access Point FIG 2 Grounding Point
Always remember to protect the access point by installing grounding lines. The ground connection must be complete before connecting power to the access point enclosure.

Before You Begin

Refer to the sections below before beginning the installation process.

NOTE:

The AP17 access point is designed in compliance with governmental requirements so that only authorized network administrators can change the settings.

Identifying Specific Installation Locations
Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should be accounted for during the planning phase and adjusted.

CAUTION:
Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.

Identifying Known RF Absorbers/Reflectors/Interference Sources
Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation phase is critical. Make sure that these sources are taken into consideration when you attach an access point to its fixed location.

RF absorbers include:

  •  Cement/concrete—Old concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration in the concrete, blocking RF signals.
  •  Natural Items—Fish tanks, water fountains, ponds, and trees
  •  Brick

RF reflectors include:

  •  Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets.
  • Do not place an access point between two air conditioning/heating ducts. Make sure that access points are placed below ducts to avoid RF disturbances.

RF interference sources include:

  •  Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)
  •  Cordless headset such as those used in call centers or lunch rooms

Outdoor Planning and Deployment Considerations
Prior to deploying an outdoor wireless network, the environment must be evaluated to plan for a successful WLAN deployment. Successfully evaluating the environment enables the proper selection of routers and antennas and assists in the determination of their placement for optimal RF coverage.

Access Point Installation

CAUTION:
Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.

The AP17 access point ships with a mount bracket to mount the AP to a solid surface, such as a wall.
The following sections provide instructions on how to use the mount bracket.

  1. Use the mount bracket as the template to mark the four mounting points on the wall.

  2. Use a drill to make four holes on the four markings from the previous step.

  3.  Insert an anchor bolt (not included in the package) into each drilled hole.

  4. Place the mount bracket over the anchor bolts and press the bracket against the wall.

  5. Place the washers and nut onto the bolt’s threaded end and tighten the nut until the mount bracket is firmly attached to the wall.
    aruba R2X11A Instant On AP17 Access Point FIG 3

  6. Slide the holder of the AP into the opening of the mount bracket and use the M6x45 screw included in the package to fix the AP to the mount bracket.
    aruba R2X11A Instant On AP17 Access Point FIG 4aruba R2X11A Instant On AP17 Access Point FIG
5

Grounding the AP
The grounding must be completed before powering up the access point. The grounding wire should be #8 AWG.

  1.  Peel the cover of one end of the grounding wire and place the bare grounding wire into the included copper lug, and press firmly with the crimping pliers.
  2.  Fasten the copper lug to the grounding hole on the AP with the included M4 x6 screw.

Powering the AP
To power the AP17 access point, connect an outdoor rated Cat5e or above Ethernet cable from the Ethernet port of the AP17 to a PoE port of a 802.3af compliant PoE Injector.
The PoE injector will be installed indoors and then a long cable will have to run from inside to outside where the AP is located. This cable will then be powering the AP. The PoE injector is not meant for outdoor installation as it is not weather tolerant. When connecting the Ethernet cable to the Ethernet port of the AP17, the included cable gland must be installed to seal the connection.

Perform the following steps:

  1.  Slide the sealing nut over the cable (without the RJ45 connector attached to the end).
  2.  Slide the gland body over the cable.
  3.  Using a crimping tool, attach the shielded RJ45 connector to the end of the cable.
  4. Remove the weatherproof cap on the Ethernet port.
  5.  Insert the RJ45 connector to the Ethernet port.
  6.  Move the seals towards the gland body until it locates at the recess of the gland body.
  7.  Screw the sealing nut onto the gland body. The Ethernet cable is now completely connected to the Ethernet port of AP17
  8.  Connect the other end of the Ethernet cable to a PoE port of a 802.3af compliant PoE Injector or PoE switch.

aruba R2X11A Instant On AP17 Access Point FIG 6 CAUTION:
Failure to use the included Ethernet cable gland can lead to connectivity and POE issues.

CAUTION:
Outdoor rated Cat5e or above cable should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE.

CAUTION:
Cable feed must be pointed downwards when wall-mounted.

NOTE:
The seals inside the clamping ring by factory default is applicable for cables with 5-8.5 mm diameter. In the cable gland kit, another seals is provided for use with the cables with 7-10 mm diameter.

Verifying Post-Installation Connectivity
The integrated LED on the AP can be used to verify that the access point is receiving power and initializing successfully (see Table 1 and Table 2).

Mobile Application Installation

Click the Apple App Store or Google Play badge below to download and install the Aruba Instant On mobile app to your phone. Launch the app and follow the instructions to complete the setup. Alternately, simply search for “Aruba Instant On” app within Apple App Store or Google Play.

Log in to Instant On Portal
Alternately, you can set up the Aruba Instant On access point from a web browser. Open a web browser and enter https://portal.ArubaInstantOn.com in the address bar to access the Aruba Instant On portal login screen. In the login screen, enter your Instant On account credentials to access your site.

Figure 7 Instant On Portal Login Screen

aruba R2X11A Instant On AP17 Access Point FIG 7

Electrical and Environmental Specifications

Electrical

  •   Ethernet:
    One 10/100/1000 Base-T auto-sensing Ethernet interface (RJ-45)

  •   Power:
    Maximum (worst-case) power consumption: 12.95W (802.3af PoE)
    Power over Ethernet (PoE): 802.3af complaint source
    Connect only to IEC 60950-1 or IEC 60601-1 3rd edition products and power sources.

Environmental

  •   Operating :
    Temperature: -40°C to +50°C (-40°F to +122°F)
    Humidity: 5% to 93% non-condensing

  • Storage and transport
    Temperature: -40°C to +70°C (-40°F to +158°F)

Regulatory Model Number

  • AP17 RMN: APEX017

Safety and Regulatory Compliance

CAUTION:
RF Radiation Exposure Statement: This equipment complies with RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

CAUTION:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Federal Communication Commission
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and receiver.
  •  Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio or TV technician for help.

Industry Canada
This Class B digital apparatus meets all of the requirements of the Canadian Interference-Causing Equipment Regulations.
This device complies with Industry Canada’s license-exempt RSS regulations. Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation.

Professional Installation Instruction
This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting.
Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty.

European Union Regulatory Conformance
The Declaration of Conformity made under Radio Equipment Directive 2014/53/EU is available for viewing at: www.hpe.com/eu/certificates. Select the document that corresponds to your device’s model number as it is indicated on the product label.

Wireless Channel Restrictions
5150-5350MHz band is limited to indoor only in the following countries; Austria (AT), Belgium (BE), Bulgaria (BG), Croatia (HR), Cyprus (CY), Czech Republic (CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR), Germany (DE), Greece (GR), Hungary (HU), Iceland (IS), Ireland (IE), Italy (IT), Latvia (LV), Liechtenstein (LI), Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia (SK), Slovenia (SL), Spain (ES), Sweden (SE), Switzerland (CH), Turkey (TR), United Kingdom (UK).

Frequency Range MHz Max EIRP
2402-2480 9 dBm
2412-2472 20 dBm
5150-5250 23 dBm
5250-5350 23 dBm
5470-5725 30 dBm
5725-5850 14 dBm

Medical

  1. Equipment not suitable for use in the presence of flammable mixtures.
  2. Connect to only IEC 60950-1 or IEC 60601-1 3rd edition certified products and power sources. The end user is responsible for the resulting medical system complies with the requirements of IEC 60601-1 3rd edition.
  3.  Wipe with a dry cloth, no additional maintenance required.
  4. No serviceable parts, the unit must be sent back to the manufacturer for repair.
  5. No modifications are allowed without Aruba approval.

NOTE:

  • This device is intended for indoor use in professional healthcare facilities.
  • This device has no IEC/EN60601-1-2 essential performance.
  • Compliance is based on the use of Aruba approved accessories.

CAUTION:

  • Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
  • Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.

aruba R2X11A Instant On AP17 Access Point FIG 8

Contact Aruba

|
---|---
Main Site| https://www.ArubaInstantOn.com
Support Site| https://support.ArubaInstantOn.com
Aruba Instant On Community| https://community.ArubaInstantOn.com
North America Telephone| 1-800-943-4526

1-408-754-1200

International Telephone| https://support.ArubaInstantOn.com

Copyright
© Copyright 2019 Hewlett Packard Enterprise Development LP

Open Source Code
This product includes code licensed under the GNU General Public License, the GNU Lesser General Public
License, and/or certain other open source licenses. A complete machine- readable copy of the source code corresponding to such code is available upon request. This offer is valid to anyone in receipt of this information and shall expire three years following the date of the final distribution of this product version by Hewlett Packard

Enterprise Company. To obtain such source code, send a check or money order in the amount of US $10.00 to:
Hewlett Packard Enterprise Company
Attn: General Counsel
6280 America Center Drive
San Jose, CA 95002
USA

Warranty
This hardware product is protected by an Aruba warranty. For details, visit
https://www.ArubaInstantOn.com/docs.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals