VIESSMANN 215955 Colour Light Signal Instruction Manual

June 9, 2024
VIESSMANN

VIESSMANN 215955 Colour Light Signal

Important information

Please read this manual completely and attentively before using the product for the first time. Keep this manual. It is part of the product.

Safety instructions

Caution:
Risk of injury!
Due to the detailed reproduction of the original and the intended use, this product can have peaks, edges and breakable parts. Tools are required for installation.

Electrical hazard!
Never put the connecting wires into a power socket! Regularly examine the transformer for damage. In case of any damage, do not use the transformer.
Make sure that the power supply is switched off when you mount the device and connect the cables!
Only use VDE/EN tested special model train transformers for the power supply!
The power sources must be protected to prevent the risk of burning cables.

Using the product for its correct purpose

This product is intended:

  • For installation in model train layouts and dioramas.
  • For connection to an authorized model train transformer (e. g. item 5200) or a digital command station.
  • For operation in dry rooms only.

Using the product for any other purpose is not approved and is considered inappropriate. The manufacturer is not responsible for any damage resulting from the improper use of this product.

Checking the package contents

Check the contents of the package for completeness:

  • Signal with connection cables, resistors and diode
  • Holding ring (2 holding rings for gauge 0)
  • Mounting clip (only for gauge 0)
  • 2 screws (only for gauge 0)
  • Board with decals (only with signals with R board)
  • Manual

Introduction

Viessmann colour light signals provide some considerable benefits: Prototypical signal aspects, a very good price-performance-ratio and they are easy to mount and to connect. The signals are detailed models of the type 1969 of the Deutsche Bahn.
The colour light signals are equipped with finely detailed metal masts. The signal heads have power-saving LEDs with nearly unlimited lifetime.
The Viessmann base socket allows simple and fast mounting from above. This does not apply to 0 scale signals.

Signal Technology

Assigning light signal cables

The cables of the colour light signals have coloured markings and a resistor. The cable of a green LED has a green marking, the cable of a red LED has a red marking and so on. The cable with the black marking and a diode instead of a resistor is the common pole for all LEDs (positive pole).

Some signals need more than one LED with the same colour to generate specific signal aspects (e. g. departure signal with distant signal at the same mast). These signals have different cables with the same markings.
In fig. 1 you can see the allocation of the signal LEDs to the outputs of the control modules resp. the decoders. For more information regarding signals please see Viessmann signal book, item 5299 – German language.

Signal aspects

Fig. 2 shows the aspects of the colour light signals. Not every signal can show every aspect.

Marking of the signals

Adhesive signs are supplied with the signal (only with signals with R board). Simply cut out the desired sign and attach it to the signal box after removing the protective foil. The Viessmann signal book item 5299 provides helpful information.

Mounting

Mounting of the H0, TT, N and Z signals
  1. Drill a hole at the mounting place. Diameter: H0, TT: 5.5 mm / N, Z: 4 mm.
  2. First insert the connection cable from above through the mounting hole. Then put the signal with the base socket inside. In case the base does not fit firmly in the hole, slide the holding ring onto the base from below.

The signal has to fit tightly in its position but you can unmount it easily

Mounting of the gauge 0 signals

Mounting on the layout

  1. Drill a hole (Ø 2.5 mm) at the mounting place.
  2. First insert the connection cable from above through the mounting hole. Screw the signal to the plate using the enclosed screws.
    In case the signal does not fit firmly in the hole, slide the holding rings onto the mounting screws from below.

Mounting on the carpet

  1. Place the mounting clip at the mounting point next to the track by placing the part with the indentations under the rails. Now you have the right distance to the track.

  2. Slide the signal foot into the intended device of the mounting clip.

  3. Slide the cables side wards out of the clip.

Connection

Caution:
Resistor and diode at the cables are needed for proper function. Never cut them off! Never cover resistor or diode with insulation material, because they have to be cooled by surrounding air!

You can connect the signals very flexibly:

  • Via switch directly to a transformer (fig. 3).
  • To a Viessmann control module.

We recommend to use a control module (e. g. items 5210 or 5220 – 5224), which offers more features and flexibility, smooth change of the lights, train control, distant signal control (e. g. fig. 4).

Technical Data

  • Operating voltage: 10 – 16 V AC ~
    14 – 24 V DC =
    13 – 24 V digital signal

  • Operating current (each LED): ca. 10 mA

Do not dispose of this product through (unsorted) domestic waste, supply it to recycling instead.

Subject to change without prior notice. No liability for mistakes and printing errors.
You will find the latest version of the manual on the Viessmann website using the item-No.

Customer Support

Viessmann Modelltechnik GmbH
Bahnhofstraße 2a
D – 35116 Hatzfeld-Reddighausen
[email protected]
+49 6452 9340-0
www.viessmann-modell.de

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VIESSMANN User Manuals

Related Manuals