MAGENE H803 Heart Rate Arm Band User Manual
- June 5, 2024
- Magene
Table of Contents
MAGENE H803 Heart Rate Arm Band
Model: H803
Product Introduction
The heart rate sensor monitors your heart rate during sports.
It supports ANT+ and Bluetooth wireless protocols, allowing you to send heart
rate data to a mobile app, bike computer, sports watch, or any other smart
device that supports standard ANT+ and Bluetooth protocols. By recording each
and every heartbeat, it enables scient ific and pleasant tra ining.
Function and Operation
Wearing: wear the armband as shown In the picture. It should be worn sung enough not to move on your arm, but not so tight that it restricts arm circulation.
Initial Setup with BLE Smart Fitness Apps
- Set Bluetooth on the device to ON
- Put on the armband and press the start-up button
- Find the Sensor Setting menu and select pair sensor in the Fitness App
Initial Setup with Smart devices
(Fitness Equipments, Sports Watches, Bike Computers)
- From the device settings menu selecrAdd Sensor”
- Put on the armband and press the start-up button
- Connect the device
Button Functions
Turn-on: Press and hold the power button for two seconds.the LED light
will flash blue ,indicating the heart rate searching
Turn-off: Press and hold the power button for two seconds when not in
use.the LED light will flash red.then enter the shutdown state
Note: If the device cannot be found in the startup state. press the butto
Specifications
Battery type | Rechargeable lithium battery |
---|---|
Battery life | Up to 45 days at 1 hr./day |
Wireless | ANT+、Bluetooth |
Heart Rate Range | 40~220BPM |
Operation Temperature | 0°C-4 5°C |
Charge Mode | Magnetic type |
Product size | 4431.611.2mm |
Weight | 12g |
Statements
FCC Statements
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications or changes to this
equipment. Such modifications or changes could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician fo help.”
The device has been evaluated to meet general RF exposure requirement, The
device can be used in portable exposure condition without restriction. Federal
Communication Commission
(FCC) Radiation Exposure Statement Power is so low that no RF exposure
calculation is needed.
CE Statements:
Declaration of Conformity
Hereby, Qingdao Magene Intelligence Technology Co., Ltd. declares that the
radio equipment type H803 of Heart Rate Armband is in compliance with
Directive 2014/53/EU.
RF exposure information: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. Radiation Exposure Statement Power is so low that no RF exposure calculation is needed.
Bluetooth(2402-2480 MHz) Max EIRP is -1.69dBm, ANT+(2457MHz) Max EIRP is -2.27dBm.
Replacement of a battery with an incorrect type that can defeat a safeguard
(such as catching fire, explosion, leakage of corrosive electrolyte etc);
Disposal of a battery into fire or a hot oven, or mechanically crushing or
cutting of a battery, that can result in an explosion; Do not expose batteries
to excessive heat such as sunshine, fire or the like;
Leaving a battery in an extremely high temperature surrounding environment
that can result in an explosion or the leakage of flammable liquid or gas; and
A battery subjected to extremely low air pressure that may result in an
explosion or the leakage of flammable liquid or gas.
RECYCLING
This product bears the selective sorting symbol for Waste electrical and
electronic equipment (WEEE). This means that this product must be handled
pursuant to European directive 2012/19/EU in order to be recycled or
dismantled to minimize its impact on the environment. User has the choice to
give his product to a competent recycling organization or to the retailer when
he buys a new electrical or electronic equipment.