aruba EC-S-P Power Supply Unit DC User Guide
- June 6, 2024
- aruba
Table of Contents
Quick Start Guide
EdgeConnect
EC-S-P
EC-M-H
Power Supply Unit, DC
Before You Begin
- Check your packing slip to verify that you have all the necessary items.
- Prepare to install the module in a proper ESD (Electrostatic Discharge) environment.
- Make sure you have a #2 Phillips screwdriver.
General Description
The EC-M-H DC base configuration includes two power supplies. The DC Power
Supply Unit (DC PSU) can replace a faulty power supply.
The EC-S-P DC base configuration includes a single DC power supply. The DC
Power Supply Unit (DC PSU) can be added as a second power supply or to replace
a faulty power supply.
The DC PSU is hot-swappable when added as a second power supply.
Initial DC PSU Installation
-
Insert the DC Cable into the Power Supply
Align and connect the DC cable into the DC power supply (3-pin blue connector – there is a ‘click’ sound when fully engaged). -
Connect the DC Cable to the Power Source
Connect the other end of the DC cable into the corresponding terminals on the user’s power source:
Red –
positive
Black – negative
Green / Yellow – ground
Use the provided cable tie to manage DC cable placement, as required
Replacing a Faulty or Adding a Second DC PSU
-
(Replacing the DC PSU) Disconnect Power Supply
Remove power supply connection by disconnecting the DC cable terminal – while squeezing together the top and bottom of the terminal connector, pull the connector from the power supply. -
Remove the faulty power supply or the power supply blank to add second power supply
When replacing a faulty power supply, press on the dark blue handle and pull the supply out of the chassis.
When adding a second power supply, remove the power supply blank by loosening the thumbscrews with the #2 Philips screwdriver and pulling the blank from the chassis.
-
Remove the Power Supply from the Packaging
-
Insert the New Power Supply
Ensure the power supply is fully engaged in the system. The dark blue latch clicks when the power supply is fully engaged. -
Connecting the DC Power Supply
Refer to the Intial DC PSU Installation steps to insert the DC Cable into the power supply and connect it to the power source.