aruba R4W01A Instant On AP22 Access Point Installation Guide
- June 6, 2024
- aruba
Table of Contents
- Package Contents
- Hardware Overview
- Before You Begin
- Identifying Specific Installation Locations
- Access Point Installation
- Verifying Post-Installation Connectivity
- Mobile Application Installation
- Log in to Instant On Portal
- Electrical and Environmental Specifications
- Regulatory Model Number
- Safety and Regulatory Compliance
- Contact Aruba
- Copyright
- Open Source Code
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
aruba R4W01A Instant On AP22 Access Point
The Aruba Instant On AP22 access point delivers high performance concurrent 2.4 GHz and 5 GHz Wi-Fi 6 (802.11ax) functionality with MIMO radios (2×2 in 2.4 GHz, 2×2 in 5 GHz), while also supporting legacy 802.11a/b/ g/n/ac wireless services.
Package Contents
- 1 x AP22 access point
- 1 x Mount bracket
- 1 x Ethernet cable
| If you
have ordered AP22 bundle, the package would also include a power supply unit
to power the AP through an electrical power outlet.
---|---
| Inform
your supplier if there are any incorrect, missing, or damaged parts. If
possible, retain the carton, including the original packing materials. Use
these materials to repack and return the unit to the supplier if needed.
---|---
Hardware Overview
LEDs
The AP22 access point has two LEDs that indicate the system and radio status of the device.
Table 1 AP22 Access Point LEDs Status
LED | Color/State | Meaning |
---|---|---|
System | No Lights | Device has no power |
Blinking Green | Device is starting | |
Alternating Green/Amber | Device is ready for setup | |
Solid Green | Device is ready | |
Solid Amber | Device has detected a problem | |
Solid Red | Device has an issue- immediate action required | |
Radio | No Lights | Wi-Fi is not ready, wireless clients cannot connect |
Solid Green | Wi-Fi is ready, wireless clients can connect |
Ethernet Port
The AP22 is equipped with a 10/100/1000Base-T auto-sensing MDI/MDX Ethernet port (E0). This E0 port supports wired-network connectivity, and Power over Ethernet (PoE) from IEEE 802.3af and 802.3at compliant PoE power sources, such as a PoE midspan injector or a network switch.
Kensington Lock Slot
The AP22 access point is equipped with a Kensington lock slot for additional security.
Reset Button
The reset button located on the bottom of the device can be used to reset the
access point to factory default settings.
There are two ways to reset the access point to factory default settings:
Reset the AP during normal operation
Press and hold down the reset button using a small, narrow object such as a
paper clip for more than 10 seconds during normal operation.
Reset the AP while powering up
- Press and hold down the reset button using a small, narrow object such as a paper clip while the access point is not powered on (either via DC power or PoE).
- Connect the power supply (DC or PoE) to the access point while the reset button is being held down. 3. Release the reset button on the access point after 15 seconds.
Power
If PoE is not available, a proprietary Aruba power adapter can be used to
power the AP22 access point. This power adapter is available in the box if you
buy the AP22 and power adapter bundle. For details, refer to the ordering
information in the AP22 data sheet at
https://www.ArubaInstantOn.com/resources.
When both PoE and DC power sources are available, the DC power source takes precedence. The access point simultaneously draws a minimal current from the PoE source. In the event that the DC source fails, the access point switches to the PoE source.
Cable Clip
The cable clip on the rear of the access point is used to organize Ethernet
cable, as shown in Figure 3. The use of the cable clip is optional and does
not support all types of cables and plugs.
Before You Begin
Refer to the sections below before beginning the installation process.
| The
AP22 access point is designed in compliance with governmental requirements so
that only authorized network administrators can change the settings.
---|---
Identifying Specific Installation Locations
Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted.
| Use of this
equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this
equipment and the other equipment should be observed to verify that they are
operating normally
---|---
Identifying Known RF Absorbers/Reflectors/Interference Sources
Identifying known RF absorbers, reflectors, and interference sources while in
the field during the installation phase is critical. Make sure that these
sources are taken into consideration when you attach an access point to its
fixed location.
RF absorbers include:
- Cement/concrete—Old concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration in the concrete, blocking RF signals.
- Natural Items—Fish tanks, water fountains, ponds, and trees
- Brick
RF reflectors include:
- Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets.
- Do not place an access point between two air conditioning/heating ducts. Make sure that access points are placed below ducts to avoid RF disturbances.
RF interference sources include:
- Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)
- Cordless headset such as those used in call centers or lunch rooms
| Portable RF
communications equipment (including peripherals such as antenna cables and
external antennas) should be used no closer than 7.87 inches (20 cm) to any
part of the access point. Otherwise, degradation of the performance of this
equipment could result.
---|---
Access Point Installation
| The installer
is responsible for securing the access point onto the ceiling tile rail in
accordance with the steps below. Failure to properly install this product may
result in physical injury and/or damage to property
---|---
| Use of
accessories, transducers and cables other than those specified or provided by
the manufacturer of this equipment could result in increased electromagnetic
emissions or decreased electromagnetic immunity of this equipment and result
in improper operation.
---|---
The AP22 access point ships with a mount bracket to install the access point to a 9/16” or 15/16” ceiling tile rail, or on a solid surface, such as a wall or a hard ceiling.
The following sections provide instructions on how to use this mount bracket.
Installing the Access Point to a Ceiling Tile Rail
-
Pull the necessary cables through a prepared hole in the ceiling tile near where the access point will be placed.
-
Place the mount bracket against the back of the access point with the mount bracket at an angle of approximately 30 degrees to the tabs (see Figure 4).
-
Twist the mount bracket clockwise until it snaps into place in the tabs (see Figure 4).
-
Hold the access point next to the ceiling tile rail with the mounting slots at approximately a 30-degree angle to the ceiling tile rail (see Figure 5 and Figure 6). Make sure that any cable slack is above the ceiling tile.
-
Pushing toward the ceiling tile, rotate the access point clockwise until the device clicks into place on the ceiling tile rail.
Installing the Access Point to a Solid Surface
-
Attach the mount bracket to any solid surface, such as a wall or hard ceiling, as shown in Figure 7.
a. Install any necessary wall anchors. Wall anchors are not included in the package.
b. Align the screw holes in the mount bracket with the previously installed anchors or demarcated screw points.
c. Insert two screws to secure the mount bracket. Screws are not included in the package. -
Attach the access point to the secured mount bracket as shown in Figure 8. a. Align the access point with the mount bracket, placing the access point so that it’s mounting tabs are at an angle of approximately 30 degrees to the mount bracket.
-
Pushing towards the solid surface, rotate the access point clockwise until it clicks into place (see Figure 8).
Verifying Post-Installation Connectivity
The integrated LEDs on the access point can be used to verify that the access point is receiving power and initializing successfully (see Table 1).
Mobile Application Installation
Click the Apple App Store or Google Play badge below to download and install
the Aruba Instant On mobile app to your phone. Launch the app and follow the
instructions to complete the setup. Alternately, simply search for “Aruba
Instant On” app within Apple App Store or Google Play.
Log in to Instant On Portal
Alternately, you can set up the Aruba Instant On access point from a web
browser. Open a web browser and enter https://portal.ArubaInstantOn.com in
the address bar to access the Aruba Instant On portal login screen. In the
login screen, enter your Instant On account credentials to access your site.
Electrical and Environmental Specifications
| All Aruba
access points should be professionally installed by an Aruba Certified
Mobility Professional (ACMP). The installer is responsible for ensuring that
grounding is available and meets applicable national and electrical codes.
---|---
Electrical
-
Ethernet:
◘ E0 port: 10/100/1000BaseT auto-sensing MDI/MDX wired RJ45 network connectivity port -
Power:
◘ 12V DC power interface, support powering through AC-to-DC power adapter
◘ Power over Ethernet (PoE): 802.3af or 802.3at compliant source
| If a
power adapter other than the Aruba-approved adapter is used in the US or
Canada, it should be NRTL listed, with an output rated 12Vdc, minimum 2A,
marked “LPS” and “Class 2”, and suitable for plugging into a standard power
receptacle in the US and Canada.
---|---
Environmental
- Operating temperature: 0°C to +40°C (+32°F to +104°F)
- Operating humidity: 5% to 93% non-condensing
Regulatory Model Number
- AP22 RMN: APIN0505
Safety and Regulatory Compliance
| RF Radiation
Exposure Statement : This equipment complies with FCC RF radiation exposure
limits. This equipment should be installed and operated with a minimum
distance of 7.87 inches (20cm) between the radiator and your body for 2.4 GHz
and 5 GHz operations. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
---|---
| Changes or
modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
---|---
Federal Communication Commission
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1)this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
manufacturer’s instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio or TV technician for help.
Industry Canada
This Class B digital apparatus meets all of the requirements of the Canadian Interference-Causing Equipment Regulations.
In accordance with Industry Canada regulations, this radio transmitter and
receiver may only be used with an antenna, the maximum type and gain of which
must be approved by Industry Canada. To reduce potential radio interference,
the type of antenna and its gain shall be chosen so that the equivalent
isotropic radiated power (EIRP) does not exceed the values necessary for
effective communication.
This device complies with Industry Canada’s license-exempt RSS regulations.
Operation of this device is subjectto the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation.
When operated in the 5.15 to 5.25 GHz frequency range, this device is
restricted to indoor use to reduce the potential for harmful interference with
co-channel Mobile Satellite Systems.
European Union Regulatory Conformance
The Declaration of Conformity made under Radio Equipment Directive 2014/53/EU is available for viewing at: www.hpe.com/eu/certificates. Select the document that corresponds to your device’s model number as it is indicated on the product label.
Wireless Channel Restrictions
5150-5350MHz band is limited to indoor only in the following countries;
Austria (AT), Belgium (BE), Bulgaria (BG), Croatia (HR), Cyprus (CY), Czech
Republic (CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR), Germany
(DE), Greece (GR), Hungary (HU), Iceland (IS), Ireland (IE), Italy (IT),
Latvia (LV), Liechtenstein (LI), Lithuania (LT), Luxembourg (LU), Malta (MT),
Netherlands (NL), Norway (NO), Poland (PL), Portugal (PT), Romania (RO),
Slovakia (SK), Slovenia (SL), Spain (ES), Sweden (SE), Switzerland (CH),
Turkey (TR), United Kingdom (UK).
Radio | Frequency Range MHz | Max EIRP |
---|---|---|
BLE/Zigbee | 2402-2480 | 9 dBm |
Wi-Fi | 2412-2472 | 20 dBm |
5150-5250 | 23 dBm | |
5250-5350 | 23 dBm | |
5470-5725 | 30 dBm | |
5725-5850 | 14 dBm |
Medical
- Equipment not suitable for use in the presence of flammable mixtures.
- Connect to only IEC 60950-1 or IEC 60601-1 certified products and power sources. The end user is responsible for the resulting medical system complies with the requirements of IEC 60601-1.
- Wipe with a dry cloth, no additional maintenance required.
- No serviceable parts, the unit must be sent back to the manufacturer for repair.
- No modifications are allowed without Aruba approval.
| This
device is intended for indoor use in professional healthcare facilities.
---|---
| This
device has no IEC/EN60601-1-2 essential performance.
---|---
| Use of this
equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this
equipment and the other equipment should be observed to verify that they are
operating normally
---|---
|
Compliance is based on the use of Aruba approved accessories.
---|---
| Use of
accessories, transducers and cables other than those specified or provided by
the manufacturer of this equipment could result in increased electromagnetic
emissions or decreased electromagnetic immunity of this equipment and result
in improper operation.
---|---
Contact Aruba
Main Site | https://www.ArubaInstantOn.com |
---|---|
Support Site | https://www.ArubaInstantOn.com/contact-support/ |
Aruba Instant On Community | https://community.ArubaInstantOn.com |
North America Telephone |
1-800-943-4526
1-408-754-1200
International Telephone| https://www.ArubaInstantOn.com/contact-
support/
Copyright
© Copyright 2020 Hewlett Packard Enterprise Development LP
Open Source Code
This product includes code licensed under the GNU General Public License, the GNU Lesser General Public License, and/or certain other open source licenses. A complete machine-readable copy of the source code corresponding to such code is available upon request. This offer is valid to anyone in receipt of this information and shall expire three years following the date of the final distribution of this product version by Hewlett Packard Enterprise Company. To obtain such source code, send a check or money order in the amount of US $10.00 to:
Hewlett Packard Enterprise Company
Attn: General Counsel
6280 America Center Drive
San Jose, CA 95002
USA
Warranty
This hardware product is protected by an Aruba warranty. For details, visit
https://www.ArubaInstantOn.com/docs.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>