Comelit CA2100A Ciao Outdoor Entrance Panel User Manual

June 6, 2024
Comelit

TECHNICAL
MANUAL

Ciao outdoor entrance panel
Art. CA2100A – CA2200

Warning

  • This Comelit product has been designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial, and public buildings.
  • All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
  • Disconnect the power supply before carrying out any operations on the wiring.
  • Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
  • We advise against running the system wires through the same duct as power cables (230V or higher).
  • To ensure Comelit products are used safely:
  • carefully observe the indications provided in the Manuals / Instruction sheets,
  • make sure the system created using Comelit products has not been tampered with / damaged.
  • Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the Manuals / Instruction sheets.
  • Any repairs must be carried out:
  • for the products themselves, exclusively by Comelit Group S.p.A.,
  • for the systems, by qualified technical personnel.
  • Comelit Group S.p.A. accepts no liability for:
  • any purpose other than the intended use,
  • failure to observe the indications and warnings contained in this Manual / Instruction sheet.
  • Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction Sheet at any time and without prior notice.

Description

Ciao series outdoor audio entrance panel for Simplebus2 system, designed for systems from 1 to 8 calls.

  • Technopolymer front covers offer resistance to atmospheric agents (protection rating IP54 and coating with anti-UV treatment) and acts of vandalism (protection rating IK08).
  • Smart button programming function.
  • Surface-mount installation support included.
  • Buttons for configurations with 1, 2, 4, or 8 calls are available to purchase separately.

Art. CA2100A

  1. Technopolymer cover
  2. Faceplate fixing screw holes
  3. Loudspeaker
  4. Call buttons 1 / 2 / 4 / 8 users (available to purchase separately)
  5. Microphone
  6. Condensation drainage hole
  7. CV2 jumper to be removed when switching off the button lighting
  8. JP1 enabling the RC network for door lock filter on relay contacts
  9. Terminal block for J4 connection: SE- SE+ connection for electric door lock NC NO C relay contacts
  10.  Terminal block for J3 connection: L L bus line connection COM RTE and DO reference negative DO door open indication RTE request to exit button
  11. LED button brightness control trimmer
  12. S2 dip switch for button addressing and special function programming
  13. S1 dip switch for button type configuration (1 / 2 / 4 /8 users)
  14. J2 and J5 6-pole connectors for button module connection
  15. SPK loudspeaker volume adjustment trimmer
  16. SW1 programming confirmation button
  17. PRC call address programming input/output switch
  18. PRS special programming input/output switch

Art. CA2200

  1. Call buttons 1 / 2 / 4 / 8 users (available to purchase separately)
  2. TM1 button brightness control/switch-off trimmer
  3. S1 dip switch for button type configuration (1 / 2 / 4 / 8 users) and button module addressing
  4. J1 and J2 6-pole connectors for connection of art. CA2100A / CA2200

Technical specifications

Art. CA2100A

GENERAL DATA

Type| Monolithic
Height (mm)| 172
Width (mm)| 100
Depth (mm)| 28
Product color| Grey RAL 9006
Coating material type| Technopolymers
Surface mounting| Yes

COMPATIBLE SYSTEMS
Simplebus2 audio with power supply unit art. 1210/1210A

AUDIO SPECIFICATIONS

Microphone| 4 (ø), omnidirectional
Loudspeaker| 50 mm (Ø), 8 Ohm, 0.2W
ELECTRICAL SPECIFICATIONS

Type of power supply| Power supply via video entry bus
Power supply voltage| 33 VDC
Absorption in standby (W)| 1.7
Maximum absorption (W)| 7.6
HARDWARE CHARACTERISTICS

Cell type| Buttons
Type of buttons| Mechanical
A number of buttons (no.)| 8
Backlighting color| White
Terminals| L L COM DO RTE C NO NC SE+ SE
Removable terminals| Yes
A number of inputs (no.)| 2
A number of outputs (no.)| 1
SETTINGS|
---|---
Backlighting brightness| Yes
Loudspeaker volume| Yes
ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS

IP protection rating| IP54
IK anti-vandal protection rating| IK08
Operating temperature (°C)| -25 to 55
Operating humidity (max RH – %)| 20 to 95
Environmental class| IV
CE certification| RoHS II – 2011/65/EU (EN 50581:2012), EMC 2014/30/EU (EN
61000-6-1:2007, EN 61000-6-3:2007+A1:2011)

Art. CA2200

GENERAL DATA

Type| Monolithic
Height (mm)| 172
Width (mm)| 100
Depth (mm)| 28
Product color| Grey RAL 9006
Surface mounting| Yes

COMPATIBLE SYSTEMS
Simplebus2 audio with power supply unit art. 1210/1210A

ELECTRICAL SPECIFICATIONS

Type of power supply| Power supply via video entry bus
Power supply voltage| 33 VDC
Absorption in standby| 0.62
Maximum absorption (W)| 0.62
HARDWARE CHARACTERISTICS

Cell type| Buttons
Type of buttons| Mechanical
A number of buttons (no.)| 16
Backlighting color| White
SETTINGS|
---|---
Backlighting brightness| Yes
ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS

IP protection rating| IP54
IK anti-vandal protection rating| IK08
Operating temperature (°C)| -25 to 55
Operating humidity (max RH – %)| 25 to 95
Environmental class| IV
CE certification| RoHS II – 2011/65/EU (EN 50581:2012), EMC 2014/30/EU (EN
61000-6-1:2007, EN 61000-6-3:2007+A1:2011)

Installing entrance panel art. CA2100A

Changing nameplates

Installing entrance panel art. CA2100A with button module art. CA2200

The addressing of button modules allows if a module art. CA2200 is replaced, just the address of the replaced module art. CA2200 to be programmed, without having to reprogram all the buttons.

Connections

Max 20 m. Local door-opener button.
Max 20 m. Active input closed for DOOR OPEN signal.

Variants

Variant for using the external unit relay

Variant for using a safety door lock
JP1 enabling the RC network for door lock filter on relay contacts
Programming call addresses other than the pre-programmed options
There are 2 programming methods:

  • Smart programming of consecutive addresses: allows quick programming of buttons with consecutive addresses (e.g.:5, 6, 7, 8)
  • Programming of specific addresses: allows programming of specific addresses (e.g.: 25, 37, 70, 58)

Smart programming of consecutive addresses

The programming procedures must be carried out in the specified order

Programming of specific addresses

The programming procedures must be carried out in the specified order

Special programs

Depending on the function you want to program, set the DIP switches in accordance with the table below.

Repeat steps 3 and 4 to program other special functions

CODE DIP SWITCHES ON FUNCTIONS Audio messages
195 1,2,7,8 Hebrew
196 3,7,8 Polish
197 1,3,7,8 Catalan
198 2,3,7,8 Galician
199 1,2,3,7,8 Basque
206 2,3,4,7,8 Danish
207 1,2,3,4,7,8 Norwegian
211 1,2,5,7,8 Swedish
215 1,2,3,5,7,8 Italian
216 4,5,7,8 French
217 1,4,5,7,8 Spanish
218 2,4,5,7,8 Dutch
219 1,2,4,5,7,8 Greek
220 3,4,5,7,8 English
221 1,3,4,5,7,8 German
222 2,3,4,5,7,8 Portuguese
202 2,4,7,8 Enables voice message (door opened warning) when the RTE contact

is closed
203| 1,2,4,7,8| Disables voice message (door opened warning) when the RTE contact is closed (default setting)
214| 2,3,5,7,8| OFF (default)
Actuator control management. N.B. the system should not include art. 1256 generic actuator mode.

227| 1,2,6,7,8| Actuator function on S serial line = enabled
228| 3,6,7,8| Actuator function on S serial line = disabled (default)
229| 1,3,6,7,8| C.NC.NO relay activation on actuator command: 2 sec
---|---|---
230| 2,3,6,7,8| C.NC.NO relay activation on actuator command: 4 sec
231| 1,2,3,6,7,8| C.NC.NO relay activation on actuator command: 8 sec
| | Door lock
---|---|---
245| 1,3,5,6,7,8| Door lock time: 2 sec. + disabling tone (default)
246| 2,3,5,6,7,8| Door lock time: 4 sec
247| 1,2,3,5,6,7,8| Door lock time: 8 sec
248| 4,5,6,7,8| Door lock confirmation tone: enabled
251| 1,2,4,5,6,7,8| Relay C.NC.NO in parallel to SE (default)
252| 3,4,5,6,7.8| Lock-release always enabled (default)
253| 1,3,4,5,6,7,8| Lock-release only enabled for user called
| | System functions
---|---|---
232| 4,6,7,8| Awaiting response time: 60 sec. (default)
233| 1,4,6,7,8| Awaiting response time: 120 sec
234| 2,4,6,7,8| Awaiting response time: 30 sec
235| 1,2,4,6,7,8| Talk time: 90 sec. (default)
236| 3,4,6,7,8| Talk time: 180 sec
239| 1,2,3,4,6,7,8| Confirmation tone on user call = enabled (default)
240| 5,6,7,8| Confirmation tone on user call = disabled
243| 1,2,5,6,7,8| Reset wait time: 10 sec (default)
244| 3,5,6,7,8| Reset wait time: 1 sec
208| 5,7,8| Enables “awaiting reset time” on lock-release command.
209| 1,5,7,8| Disables “awaiting reset time” on lock-release command (awaiting response time or talk time will be activated)
249| 1,4,5,6,7,8| Send call: single (default)
250| 2,4,5,6,7,8| Call transmission: triple
| | System mode
---|---|---
0| | Simplebus (default)
255| 1,2,3,4,5,6,7,8| Simplebus Top
254| 2,3,4,5,6,7,8| Restore default

Operating notes

When a call is transmitted from the external unit, if a busy tone is heard instead of the ringtone, this means communication with another external unit is in progress.

System performance and layouts

For further information on system performance and to view installation layouts, click on the system type that best meets your requirements:

  • Audio kit for the creation of audio systems for detached homes
  • SB2 audio system kit for the creation of audio systems for residential complexes

Addressing table

Code| Dip switch
ON| | | | | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
1| 1| 31| 1,2,3,4,5| 61| 1,3,4,5,6| 91| 1,2,4,5,7| 121| 1,4,5,6,7| 151| 1,2,3,5,8| 181| 1,3,5,6,8| 211| 1,2,5,7,8
2| 2| 32| 6| 62| 2,3,4,5,6| 92| 3,4,5,7| 122| 2,4,5,6,7| 152| 4,5,8| 182| 2,3,5,6,8| 212| 3,5,7,8
3| 1.2| 33| 1,6| 63| 1,2,3,4,5,6| 93| 1,3,4,5,7| 123| 1,2,4,5,6,7| 153| 1,4,5,8| 183| 1,2,3,5,6,8| 213| 1,3,5,7,8
4| 3| 34| 2.6| 64| 7| 94| 2,3,4,5,7| 124| 3,4,5,6,7| 154| 2,4,5,8| 184| 4,5,6,8| 214| 2,3,5,7,8
5| 1,3| 35| 1,2,6| 65| 1,7| 95| 1,2,3,4,5,7| 125| 1,3,4,5,6,7| 155| 1,2,4,5,8| 185| 1,4,5,6,8| 215| 1,2,3,5,7,8
6| 2,3| 36| 3,6| 66| 2,7| 96| 6.7| 126| 2,3,4,5,6,7| 156| 3,4,5,8| 186| 2,4,5,6,8| 216| 4,5,7,8
7| 1,2,3| 37| 1,3,6| 67| 1,2,7| 97| 1,6,7| 127| 1,2,3,4,5,6,7| 157| 1,3,4,5,8| 187| 1,2,4,5,6,8| 217| 1,4,5,7,8
8| 4| 38| 2,3,6| 68| 3,7| 98| 2,6,7| 128| 8| 158| 2,3,4,5,8| 188| 3,4,5,6,8| 218| 2,4,5,7,8
9| 1,4| 39| 1,2,3,6| 69| 1,3,7| 99| 1,2,6,7| 129| 1,8| 159| 1,2,3,4,5,8| 189| 1,3,4,5,6,8| 219| 1,2,4,5,7,8
10| 2,4| 40| 4,6| 70| 2,3,7| 100| 3,6,7| 130| 2,8| 160| 6,8| 190| 2,3,4,5,6,8| 220| 3,4,5,7,8
11| 1,2,4| 41| 1,4,6| 71| 1,2,3,7| 101| 1,3,6,7| 131| 1,2,8| 161| 1,6,8| 191| 1,2,3,4,5,6,8| 221| 1,3,4,5,7,8
12| 3,4| 42| 2,4,6| 72| 4,7| 102| 2,3,6,7| 132| 3,8| 162| 2,6,8| 192| 7,8| 222| 2,3,4,5,7,8
13| 1,3,4| 43| 1,2,4,6| 73| 1,4,7| 103| 1,2,3,6,7| 133| 1,3,8| 163| 1,2,6,8| 193| 1,7,8| 223| 1,2,3,4,5,7,8
14| 2,3,4| 44| 3,4,6| 74| 2,4,7| 104| 4,6,7| 134| 2,3,8| 164| 3,6,8| 194| 2,7,8| 224| 6,7,8
15| 1,2,3,4| 45| 1,3,4,6| 75| 1,2,4,7| 105| 1,4,6,7| 135| 1,2,3,8| 165| 1,3,6,8| 195| 1,2,7,8| 225| 1,6,7,8
16| 5| 46| 2,3,4,6| 76| 3,4,7| 106| 2,4,6,7| 136| 4,8| 166| 2,3,6,8| 196| 3,7,8| 226| 2,6,7,8
17| 1,5| 47| 1,2,3,4,6| 77| 1,3,4,7| 107| 1,2,4,6,7| 137| 1,4,8| 167| 1,2,3,6,8| 197| 1,3,7,8| 227| 1,2,6,7,8
18| 2,5| 48| 5.6| 78| 2,3,4,7| 108| 3,4,6,7| 138| 2,4,8| 168| 4,6,8| 198| 2,3,7,8| 228| 3,6,7,8
19| 1,2,5| 49| 1,5,6| 79| 1,2,3,4,7| 109| 1,3,4,6,7| 139| 1,2,4,8| 169| 1,4,6,8| 199| 1,2,3,7,8| 229| 1,3,6,7,8
20| 3,5| 50| 2,5,6| 80| 5,7| 110| 2,3,4,6,7| 140| 3,4,8| 170| 2,4,6,8| 200| 4,7,8| 230| 2,3,6,7,8
21| 1,3,5| 51| 1,2,5,6| 81| 1,5,7| 111| 1,2,3,4,6,7| 141| 1,3,4,8| 171| 1,2,4,6,8| 201| 1,4,7,8| 231| 1,2,3,6,7,8
22| 2,3,5| 52| 3,5,6| 82| 2,5,7| 112| 5.67| 142| 2,3,4,8| 172| 3,4,6,8| 202| 2,4,7,8| 232| 4,6,7,8
23| 1,2,3,5| 53| 1,3,5,6| 83| 1,2,5,7| 113| 1,5,6,7| 143| 1,2,3,4,8| 173| 1,3,4,6,8| 203| 1,2,4,7,8| 233| 1,4,6,7,8
24| 4.5| 54| 2,3,5,6| 84| 3,5,7| 114| 2,5,6,7| 144| 5.8| 174| 2,3,4,6,8| 204| 3,4,7,8| 234| 2,4,6,7,8
25| 1,4,5| 55| 1,2,3,5,6| 85| 1,3,5,7| 115| 1,2,5,6,7| 145| 1,5,8| 175| 1,2,3,4,6,8| 205| 1,3,4,7,8| 235| 1,2,4,6,7,8
26| 2,4,5| 56| 4,5,6| 86| 2,3,5,7| 116| 3,5,6,7| 146| 2,5,8| 176| 5,6,8| 206| 2,3,4,7,8| 236| 3,4,6,7,8
27| 1,2,4,5| 57| 1,4,5,6| 87| 1,2,3,5,7| 117| 1,3,5,6,7| 147| 1,2,5,8| 177| 1,5,6,8| 207| 1,2,3,4,7,8| 237| 1,3,4,6,7,8
28| 3,4,5| 58| 2,4,5,6| 88| 4,5,7| 118| 2,3,5,6,7| 148| 3,5,8| 178| 2,5,6,8| 208| 5,7,8| 238| 2,3,4,6,7,8
29| 1,3,4,5| 59| 1,2,4,5,6| 89| 1,4,5,7| 119| 1,2,3,5,6,7| 149| 1,3,5,8| 179| 1,2,5,6,8| 209| 1,5,7,8| 239| 1,2,3,4,6,7,8
30| 2,3,4,5| 60| 3,4,5,6| 90| 2,4,5,7| 120| 4,5,6,7| 150| 2,3,5,8| 180| 3,5,6,8| 210| 2,5,7,8| *240| 5,6,7,8

CERTIFIED MANAGEMENT SYSTEMS

www.comelitgroup.com
Via Don Arrigoni, 5 – 24020 Rovetta (BG) – Italy

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals