RFSA-61M/MI Wireless Switch Unit
Instruction Manual
Characteristics
-
RFSA-61M/MI: the switching unit with 1 output channel is used for controlling appliances, sockets, or lights.
– The one-module design of the unit into a switchboard enables the connection of a switched load up to 16 A (4.000 W).
– The switching unit may be controlled by up to 25 channels (1 channel represents 1 button on the controller). -
RFSA-66M/MI: the switching unit with 6 output channels is used for independent control of up to 6 appliances, sockets or lights. It is possible to assign any function to each output relay.
– The three-module design of the unit into a switchboard enables the connection of a switched load 6 x 8A (6 x 2000 W).
– It is just right for creating scenes, wherewith one push of the controller, you can switch on or off all 6 channels simultaneously.
– Each of the channels may be controlled by up to 25 channels (1 channel represents one button on the controller). -
They can be combined with detectors, controllers, iNELS RF Control, or system components.
-
The integrated switching contact enables connection, where the controlled appliance may be switched on or off by command.
-
Function: button, impulse relay, and time function of a delayed start or return with time setting range of 2s-60 min.
-
The programming button on the unit is also used for manual control of the output.
-
For components with an antenna connector, the package includes an internal AN-I antenna; if the component is placed in a sheet metal cabinet, you can use an external AN-E antenna to improve the signal.
-
Memory status can be pre-set in the event of a power failure.
-
For components labeled as iNELS RF Control 2 (RFIO 2 ), it is possible to set the repeater function via the RFAF/USB service device.
-
Range up to 200 m (in open space ), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO 2 that supports this feature.
-
Communication frequency with bidirectional protocol iNELS RF Control 2 (RFIO 2 ).
-
The RFSA-61M/MI and RFSA-66M/MI components are not intended for installation in closed all-metal switchboards, conversely, they are designed for plastic sub-switchboards.
Assembly
mounting into switchboard
Connection
RFSA-61M/MI/230V
RFSA-61M/MI/24V
RFSA-66M/MI/230V
RFSA-66M/MI/24V
Radiofrequency signal penetration through various construction materials
| | | |
---|---|---|---|---
60 – 90 %| 80 – 95 %| 20 – 60 %| 0 – 10 %| 80- 90 %
brick walls| wooden structures
with plasterboards| reinforced
concrete| metal partitions| common glass
For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures
Indication, manual control
-
LED Un – green – power supply indication.
-
LED STATUS – red – a status indication of individual channels.
Indicators of memory function:
On – LED blinks x 3.
Off – The LED lights up once for a long time. -
Manual control is performed by pressing the PROG button for less than 1s.
-
Programming is performed by pressing the PROG button for more than 1s.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.
Compatibility
The device can be combined with all system components, controls, and devices
of iNELS RF Control and iNELS RF Control².
The detector can be assigned an iNELS RF Control² (RFIO²) communication
protocol.
Functions and programming with RF transmitters
Function button
The output contact will be closed by pressing the button and opened by
releasing the button.
For the correct execution of individual commands (press = closing / releasing
the button = opening), the time delay between these commands must be a min.
1s (press – delay 1s – release).
Programming
Press of programming button on receiver RFSA-61M/ MI (66M/MI) for 1 second will activate receiver RFSA-61M/MI (66M/MI) into programming mode. LED is flashing in 1s interval.
Select and press one button on the wireless switch, to this button will be assigned function Button.
Press of programming button on receiver RFSA-61M/MI (66M/MI) shorter than 1
second will finish programming mode.
The LED lights up according to the pre-set memory function.
Description of switch-on
The output contact will be closed by pressing the button.
Programming
Press of programming button on receiver RFSA-61M/ MI (66M/MI) for 1 second will activate receiver RFSA-61 M/MI (66M/MI) into programming mode. LED is flashing in 1s interval.
Two presses of your selected button on the RF transmitter assign the function switch on (must be a lapse of 1s between individual presses).
Press of programming button on receiver RFSA-61M/MI (66M/MI) shorter than 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function switch off
Description of switch off
The output contact will be opened by pressing the button.
Programming
Press of programming button on receiver RFSA-61M/ MI (66M/MI) for 1 second
will activate receiver RFSA-61M/MI (66M/MI) into programming mode.
LED is flashing in 1s interval.
Three presses of your selected button on the RF transmitter assign the function switch off (must be a lapse of 1s between individual presses).
Press of programming button on receiver RFSA-61M/MI (66M/MI) shorter then 1
second will finish programming mode.
The LED lights up according to the pre-set memory function.
Function impulse relay
Description of impulse relay
The output contact will be switched to the opposite position by each press of
the button. If the contact was closed, it will be opened and vice versa.
Programming
Press of programming button on receiver RFSA-61M/ MI (66M/MI) for 1 second
will activate receiver RFSA-61M/MI (66M/MI) into programming mode.
LED is flashing in 1s interval.
Four presses of your selected button on the RF transmitter assign the function impulse relay (must be a lapse of 1s between individual presses).
Press of programming button on receiver RFSA-61M/MI (66M/MI) shorter than 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function delayed off
Description of delayed off
The output contact will be closed by pressing the button and opened after the
set time interval has elapsed.
Programming Press of programming button on receiver RFSA-61M/ MI (66M/MI)
for 1 second will activate receiver RFSA-61M/MI (66M/MI) into programming
mode.
LED is flashing in 1s interval.
Assignment of the delayed offfunction is performed by five presses of the
selected button on the RF transmitter (must be a lapse of 1s between
individual
presses).
Press of programming button longer than 5 seconds, will activate actuator into timing mode. LED flashs 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting.
After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
Press of programming button on receiver RFSA-61M/MI (66M/MI) shorter than 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Description of delay on
The output contact will be opened by pressing the button and closed after the set time interval has elapsed.
Programming Press of programming button on receiver RFSA-61M/MI (66M/ MI) for 1 second will activate receiver RFSA-61M/MI (66M/MI) into programming mode. LED is flashing in 1s interval.
Assignment of the delayed function is performed by six presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
Press of programming button longer than 5 seconds, will activate actuator into
timing mode.
LED flashs 2x in each 1s interval. Upon releasing the button, the delayed
return time starts counting.
After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
Press of programming button on receiver RFSA-61M/MI (66M/MI) shorter than 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Programming with RF control units
RFSA-61M/MI: the address listed on the front side of the actuator is used for
programming and controlling an RF actuator by control units.
RFSA-66M/MI: addresses listed on the front side of the actuator are used for
programming and controlling the actuator and individual RF channels by control
units.
Delete actuator
Deleting one position of the transmitter
By pressing the programming button on the actuator for 5 seconds, the deletion
of one transmitter activates. LED flashs 4x in each 1s interval. Pressing the
required button on the transmitter deletes it from the actuator’s memory. To
confi rm deletion, the LED will confi rm with a flash long and the component
returns to the operating mode.
The memory status is not indicated.
Deletion does not affect the pre-set memory function.
Deleting the entire memory
By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED flashes 4x in each is an interval. The actuator goes into the programming mode, the LED flashes in 0.5s intervals (max. 4 min.). You can return to the operating mode by pressing the Prog button for less than ls. The LED lights up according to the pre-set memory function and the component returns to the operating mode. Deletion does not affect the preset memory function.
Selecting the memory function
Press of programming button on receiver RFSA-61M/MI (66M/MI) for 1 second will
activate receiver RFSA-61M/MI (66M/MI) into programming mode.
LED is flashing in 1s interval.
Pressing the programming button on the RFSA-61M/MI (66M/MI) receiver for less than 1 second will finish the programming mode, this will reverse the memory function. The LED lights up according to the current pre-set memory function. The set memory function is saved. Every other change is made in the same way.
-
Memory function on:
– For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
– For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state. -
Memory function off:
When the power supply is reconnected, the relay remains off.
Technical parameters
Supply voltage:| 110-230VAC/50-60Hz| 12-24 V AC/DC SELV| 110-230VAC/50-60Hz|
12-24 V AC/DC SE LV
---|---|---|---|---
Apparent input:| 2.7 VA / cos, = 0.6| | min. 2VA /max. 5VA|
Dissipated power:| 1.62 W| 0.8 W| min.0.5W/max.2.5W| max. 1.8 W
Supply voltage tolerance:| +10% / -25 %
Output|
Number of contacts:| lx switching / piepinaci (AgSnO)| 3x switching /
piepinaci (AgSnO,);
3x switching / spinal (AgSnO,)
Rated current:| 16 A/A0| 8 A/AC1
Switching power:| 4000 VA / AO, 384 W /IX| 2000VA/ACI
Peak current:| 30 A/<3s| 10 A/<3 s
Switching voltage:| 250V AO /24V DC| 250 V AC
Min. DC switching power:| 500 mW| 500 mW
Mechanical service life:| 3×10′| lx10.
Electrical service life (ACI):| 0.7×10′| 1×10′
Control|
RF, by command from transmitter:| 866 MHz, 868 MHz, 916 MHz
Manual control:| button PROD (ON/OFF)
Range in free space:| up to / ai 200 m
Output for RF antenna:| SMA connector
Other data|
Operating temperature:| -15`C…+ 50°C
Operating position:| any /
Mounting:| DIN rail EN 60715
Protection:| IP20 from the front panel
Overvoltage category:| III.
Contamination degree:| 2
Connecting conductor cross-section (mrri):| max. lx2.5, max. 2×1.5 / with a
hollow
Dimensions:| 90x 17.6 x 64mm| 90x 52 x 65mm
Weight:| 74 g| 264 g
Related standards:| EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No
426/2000 Coll. (Directive 1999/EC) /EN 60669, EN 300 220, EN 301 489 smile
RITE, NVC426/2000Sb (service 1999/ES)
- Max Tightening Torque for antenna connector is 0.56 Nm.
Attention:
When you install an iNELS RF Control system, you have to keep a minimum distance of 1 cm between each units between the individual commands must be an interval of at least 1s.
Warning
The instruction manual is designated for mounting and also for users of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. The trouble-free function of the device also depends on transportation, storing, and handling. In case you notice any sign of damage, deformation, malfunction, or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting the installation, make sure that all wires, connected parts, or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives, and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – a life threat. Due to the transmissivity of RF signal, observe the correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. They must not be installed into metal switchboards and into plastic switchboards with metal doors – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – the radiofrequency signal can be shielded by an obstruction, interfere, battery of the transceiver can get flat etc. and thus disable the remote control.
ELKO EP declares that the RFSA-61M/MI, RFSA-66M/MI type of equipment complies
with Directives 2014/30/EU, 2011/65/EU, 2015/863/EU and
2014/35/EU. The full EU Declaration of Conformity is available at:
www.elkoep.com/wireless-switch-unit-multi-function-1-output-rfsa-61m
www.elkoep.com/wireless-switch-unit—6-outputs-rfsa-66m
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
Tel.: +420 573 514 211, e-mail: elko@elkoep.com,
www.elkoep.com
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly
e-mail: elko@elkoep.cz
Support: +420 778 427 366
www.elkoep.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>