Specifications

Headset
SD 10 HS | SD 20 HS | SD 30 HS

  • Dimensions (W x H x D)
    • SD 10 HS:
    • 140 x 24 x 22 mm /
    • 5.51 x 0.95 x 0.87 in
    • SD 20 HS / SD 30 HS:
    • 170 x 175 x 55 mm /
    • 6.69 x 6.89 x 2.17 in
  • Weight
    • SD 10 HS: Weight with…
    • Ear hook: 22 g / 0.78 oz / 0.049 lbs
    • Headband: 50 g / 1.76 oz / 0.11 lbs
    • SD 20 HS: 65 g / 2.29 oz / 0.14 lbs
    • SD 30 HS: 85 g / 3.00 oz / 0.19 lbs
  • Talk time
    • Narrowband: up to 12 hours
    • Wideband : up to 8 hours
  • Charging time
    • 50%: approx. 20 min
    • 100%: approx. 1 hour
  • Range (environment dependent)
    • Free line of sight: up to 180 m / 590 ft
    • in office buildings: up to 55 m / 180 ft
  • Speaker type
    • Dynamic, neodymium magnet
  • Microphone type
    • Electret microphone,
    • noise canceling

Base station
SD BS ML – US

  • Dimensions (W x H x D)
    • 83 x 127 x 121 mm /
    • 3.27 x 5.00 x 4.76 in
  • Weight
    • 337 g / 11.89 oz / 0.74 lbs

Base station and Headset

  • DECT frequency range
    • DECT frequency range
  • RF output power
    • max. 135 mW (EIRP)
  • Temperature range
    • Operation:+5 °C t o +45 °C / +41 °F to +113 °F
    • Storage: 0 °C to +70 °C / -4 °F to +158 °F

Power supply unit
UNI PS US 01

  • Nominal input voltage 100 – 240 V~
  • Nominal input current max. 0.2 A
  • Mains frequency 50 – 60 Hz
  • Nominal output voltage 5.9 V DC
  • Nominal output current max. 850 mA
  • Temperature range
    • Operation :+ 5 °C to +45 °C /+41 °F to +113 °F
    • Storage : –20 °C to +70 °C /–4 °F to +15
  • Relative humidity
    • operation: 20 to 85%
    • storage: 20 to 95%
  • Weight approx. 75 g / 2.65 oz / 0.17 lbs

FCC

Statements regarding FCC and Industry Canada
This device complies with Part 15 of the FCC rules and Innovation, Science and Economic Development Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference; and
  2. This device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifi cations made to this equipment not expressly approved by the manufacturer may void the FCC authorization to operate this equipment.

The device complies with FCC / Innovation, Science and Economic Development Canada’s RF radiation exposure limits set forth for an uncontrolled environment. Use of other accessories not verifi ed by the manufacturer may not ensure compliance with FCC / Innovation, Science and Economic Development Canada’s RF exposure guidelines. These transmitters must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment has been tested and found to comply with the limits for a Class B digital device of the FCC Rules, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit diff erent from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

RF Radiation Exposure Information
The device complies with FCC and Innovation, Science and Economic Development Canada RF radiation exposure limits set forth for an uncontrolled environment. The base station should be installed and operated with minimum distance of 20 cm between the radiator and your body. Use of other accessories not verifi ed by the manufacturer may not ensure compliance with FCC/ISED RF exposure guidelines. These transmitters must not be co-located or operated in conjunction with any other antenna or transmitter.

Responsible party
Demant Sound USA, Inc.
Little Falls Drive, Wilmington 19800, New Castle, USA
Tel: +1 800-332-7439
DSEA A/S
Kongebakken 9, DK-2765 Smørum, Denmark, www.eposaudio.com,
Printed in China, 04/21, 770-00257/A07

In compliance with:
Model: SD 10 HS, SD 20 HS, SD 30 HS, SCDB13 (SD BS ML – US)

USA
FCC ID: R3USCDB9 (base station)
FCC ID: R3UD10HS (headset)

Canada
IC: 2099D-SCDB13 (base station)
IC: 2099D-TDH1 (headset)
CAN ICES-3 (B)/NMB-3 (B)

The compliance markings can be found under the headset earpad.