CREATE Silkair Home Portable 3 In 1 Air Conditioner User Manual

June 6, 2024
CREATE

Silkair Home Portable 3 In 1 Air Conditioner
User Manual

Thank you for choosing our air conditioner. Before using the appliance, and to ensure the best use, carefully read these instructions.
The safety precautions enclosed herein reduce the risk of death, injury, and electrical shock when correctly adhered to. Keep the manual in a safe place for future reference, along with the completed warranty card, purchase receipt, and package. If applicable, pass these instructions on to the next owner of the appliance. Always follow basic safety precautions and accident- prevention measures when using an electrical appli­ ance. We assume no liability for customers failing to comply with these requirements.

SECURITY INSTRUCTIONS

When using any electrical appliance, basic safety precautions should always be ob­served.
The refrigerant used in mobile air conditioners is environmentally friendly hydro­carbon R290. This refrigerant is odorless and compared to the alternative refrigerant, the R290 is an ozone-free refrigerant, and its effect is very low.

  • Please read the instructions before use and repair.

  • The drawings provided in this manual may not be the same as the physical objects.
    Please refer to the physical objects.

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

  • The appliance shall be stored in a room without continuously operating ignition sources (for example open flames, an operating gas appliance or an operating elec­tric heater.)

  • Do not pierce or burn.

  • Be aware that refrigerants may not contain an odor

  • The appliance shall be installed, operated, and stored in a room with a floor area larger than 7 me7,

  • Keep any required ventilation openings clear of obstruction.
    Servicing shall be performed only as recommended by the manufacturer  The appliance shall be stored in a well-ventilated area where the room size corre
    sponds to the room area as specified for operation,

  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment au­authority, which authorizes their competence to handle refrigerants safely in accord­ ance with an industry-recognized assessment specification,

  • Servicing shall only be performed as recommended by the equipment manufacturer

  • Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

  • All working procedure that affects safety means shall only be carried by competent persons.

Notes: The air conditioner is only suitable for indoor use, and is not suitable for other applications.

  • Follow local grid interconnection rules while installing the air conditioner and ensure that it is properly grounded. If you have any question on electrical in-
    stallation, follow the instructions of the manufacturer, and if necessary, ask a professional electrician to install it.
    Place the machine in a flat and dry place and keep a distance of above 50 cm between the machine and the surrounding objects or walls.
    After the air conditioner is installed, ensure that the power plug is intact and firmly plugged into the power outlet, and place the power cord orderly to pre­
    vent someone from being tripped or pulling out the plug.

  • Do not put any object into the air inlet and outlet of the air conditioner. Keep the air inlet and outlet free from obstructions.
    When drainage pipes are installed, ensure that the drainage pipes are properly connected, and are not distorted or bent.

  • While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to avoid damaging wind-guide strips.
    When moving the machine, make sure that it is in an upright position.

  • The machine should stay away from gasoline, flammable gas, stoves, and other heat sources.

  • Don’t disassemble, overhaul and modify the machine arbitrarily, otherwise, it will cause a machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine failure occurs, ask the manufacturer or professionals to repair it.

  • Do not install and use the air conditioner in the bathroom or other humid envi­ ronments.

  • Do not pull the plug to turn off the machine.

  • Do not place cups or other objects on the body to prevent water or other liquids from spilling into the air conditioner, Do not use insecticide sprays or other flammable substances near the air con­ conditioner, Do not wipe or wash the air conditioner with chemical solvents such as gasoline and alcohol. When you need to clean the air conditioner, you must disconnect the power supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
    The appliance can be used by children aged from 8 years and above and per­ sons with reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
    Cleaning and maintenance shall not be made by children without supervision.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its ser­ vice agent or similarly qualified persons in order to avoid a hazard.

  • The appliance shall be installed in accordance with national wiring regulations.

  • Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

FEATURES

Brand new appearance, compact structure, smooth Line, simple and generous shape.

  • Functions of refrigeration, dehumidification, air supply and continuous drainage.
    Outdoor interface is set high to make assembly easy and keep the smooth flow of heat pipe.

  • LED displays the control panel, beautiful and fashionable, with high-quality remote control. It adopts a user-friendly remote control design.

  • Air filtration capability.

  • Timing switch function.

  • Protection function of automatically restarting the compressor after three minutes, a variety of other protection functions.

  • Temperature operation range: 7-35°C.

PARTS LIST

CREATE Silkair Home Portable 3 In 1 Air Conditioner - PARTS
LIST

1. Top cover 8. EVA filter
2. Control panel 9. Continuous drainage hole
3. Air outlet/grid 10.Air vent
4. Handle 11. CON filter
5. Rear housing 12. Drainage hole
6. Front housing 13. Exhaust pipe
7. Caster wheels 14.Window sealing plate

CONTROL PANEL

CREATE Silkair Home Portable 3 In 1 Air Conditioner - CONTROL
PANEL

1.Dehumidifier 7. Power
2. Cooling 8. Fan
3. Screen 9. Low fan speed
4. Water full light 10.High fan speed
5. Timer 11, Sleep
6. Up 12.Down

When the appliance is powered on for the first time, you will hear a short power-on music. Then the device will get into standby status.

  • power key: To turn on and off the device.
    Up/ Down keys: To change temperature and time settings. (Temperature can’t be set while in dehumidifiying mode.)
    High /Low fan speed keys: To set the strongest or lowest air flow automatically.

  • Sleep mode: The unit will work on energy-saving and quiet mode.
    Air flow speed selection: In cooling and fan mode you can select high or low air flow.
    But it may not work as set under certain conditions, as anti-cold conditions.
    Dehumidifier: Pressing any key is invalid in this mode and the fan will work on low air flow speed.

  • Cooling key: To start cooling the room
    Water full light: The device will stop working when the water tank is full and needs to be drained away
    Timer: Press this key and when the timing light flashes press up or down keys to select the required time, from 1 to 24 hours

REMOTE CONTROL

1. Screen 5. Up/ Down
2. Power 6. Modes
3. Timer 7. Fan speeds
4. Sleep mode 8. Temperature unit

PROTECTION FUNCTIONS

FROST PROTECTION FUNCTION
In cooling, dehumidifying or economic power-saving mode, if the temperature of the exhaust pipe is too low, the air conditioner will automatically enter protection status; if the temperature of the exhaust pipe rises to a certain temperature, it can automat­ ically revert to normal operation.
OVERFLOW PROTECTION FUNCTION
When water in the water tank exceeds the warning level, the machine will automati­ cally sound an alarm, and the full indicator light will flash. At this point, you need to move the drainage pipe connecting the device or the water outlet to a sewer or other drainage area to empty the water After the water is emptied, the device will automat­ ically return to the original state.
AUTOMATIC DEFROSTING
The machine has automatic defrosting function. De rosting can be achieved through a four-way valve reversing system.
COMPRESSOR PROTECTION FUNCTION
To increase the service life of the compressor, it has a 3-minute delay booting protec­ tion function after the compressor is turned off.

INSTALLATION AND ADJUSTMENT

Warning: Before using this portable air conditioner, keep it upright for at least two hours.
The air conditioner can be easily moved in the room. In the moving process, ensure that the air conditioner is in the upright position and the air conditioner  hould be placed on a flat surface. Do not install and use the air conditioner in the bathroom or other humid environments.

INSTALLATION OF THE HEAT PIPE

  1. Take out the outer connector assembly and the exhaust pipe assembly, and re­ move the plastic bags;
  2. insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent slot (push to the left) and complete the assembly.

INSTALLATION OF THE WINDOW SEALING PLATE

  1. Half open the window and mount the window sealing plate assembly to the window. Components can be placed in horizontal and vertical direction.
  2. Pull the components of the window sealing plate assembly open, adjust their open­ ing distance to bring both ends of the assembly into contact with the window frame, and fix the components of the assembly.

Notes:
The flat end of the exhaust pipe joints must be snapped into place. The pipe cannot be distorted nor have substantial turning (greater than 45°). Keep the ventila­ tion of the exhaust pipe not blocked.

CREATE Silkair Home Portable 3 In 1 Air Conditioner - WINDOW SEALING
PLATE

INSTALLATION OF THE APPLIANCE

  1. Move the air conditioner with installed heat pipe and fittings in front of the window, and the distance between the body and walls or other objects shall be of at least 50 cm.

  2. Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the window sealing plate assembly.
    Important Notice: The length of the exhaust hose shall be between 280 and 1,500mm, and this length is based on the specifications of the air conditioner. Do not use exten­ sion tubes or replace it with other different hoses, or this may cause a malfunction. Exhaust host must be not blocked; otherwise it may cause overheating.

CREATE Silkair Home Portable 3 In 1 Air Conditioner - INSTALLATION OF THE
APPLIANCE 1

DRAINAGE INSTRUCTIONS

MANUAL DRAINAGE

When the air conditioner stops after the water tank is full, turn off the machine power and unplug the power plug.
Notes: Please move the appliance careful­ ly, so as not to spill the water in the water tank at the bottom of the body.
Place the water container below the side
water outlet behind the body.

  • Unscrew the drainage cover and unplug  the water plug, the water will automati­ cally flow into the water container

Notes: Keep the drainage cover and the water plug properly.

  • During drainage, the body can be tilted slightly backwards.
  • If the water tank cannot hold all the water, before it is full stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
  • When the water is discharged, stuff the water plug, and tighten the drainage cover

CONTINUOUS DRAINAGE (OPTIONAL, ONLY APPLICABLE TO DEHUMIDIFY-ING MODE)

  • Unscrew the drainage cover, and unplug the water plug.
  • Set the drainage pipe into the water outlet.
  • Connect the drainage pipe to the bucket.

MAINTENANCE

Before performing tasks of cleaning and maintenance, turn off the machine and un­ plug it.

CREATE Silkair Home Portable 3 In 1 Air Conditioner
-MAINTENANCE

  1. Clean the surface:
    Clean the surface of the machine with a wet soft cloth. Don’t use chemicals, such as benzene, alcohol, gasoline, etc; oth­ erwise, the surface of the air conditioner will be damaged or even the whole ma­ chine will be damaged.

  2. Clean the filter screen:
    •If the filter screen is clogged with dust, and the effectiveness of the air condi­ tioner is reduced, be sure to clean the filter screen once every two weeks.

  3. Clean the upper filter screen frame:
    • Unscrew one screw fixed by EVA filter net and back shell with screwdriver, and take out EVA filter net.
    •put the EVA filter screen into warm water with neutral detergent (about 40/104 9C)  and dry it in the shade after rinsing clean.

STORAGE

  • Unscrew the drainage cover, unplug the water plug, and discharge the water in the water tank into other water containers or directly tilt the body to discharge the water into other containers.
  • Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes
  • dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.
  • Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the water plug and the drainage cover.
  • Remove the exhaust pipe and keep it properly.
  • Cover the air conditioner with a plastic bag. Put it in a dry place, keep it out of the reach of children, and take dust control measures.
  • Remove batteries of the remote control and keep them properly.

Note: ensure that the body is placed in a dry place and keep all machine components properly.

TROUBLESHOOTING

Do not repair or disassemble the air conditioner by yourself. Unqualified repair will Lead to failure of the warranty, and may cause damage to users or their properties.

PROBLEM POSSIBLE CAUSE SOLUTION

The does air conditioner not  work

| There is no electricity| Turn it on after connecting it to a socket with electricity.
The overflow indicator displays ‘FL| Discharge the water inside.
The ambient temperature is too low or too high.| Recommend to use the machine in at the temperature of 7-35 °C (44-95 °F).
in cooling mode, the room ternperature is lower than the set temperature.| Change the set temperature.
in dehumidification mode, the ambient temperature is low.| The machine is placed in a room with an ambient temperature over 17 °C (62 °F).
There is direct sunlight.| Pull the curtains.
The cooling effect is not good.

| Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat| Close doors and windows, and add new air conditioner.
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions.
Big Noise.| The Sr conditioner is not placed on a flat surface.| Put the air conditioner on a flat and hard place (to reduce noise).
---|---|---
Compressor does not work.| Overheat protection starts.| Wait for 3 minutes until the temperature is lowered, and then restart the machine.

The remote control does not work.

| The distance between the machine and the remote control is too far| Let the remote control get close to the air conditioner, and make sure ‘that remote control
The remote control is not
aligned with the direction of the remote control receiver.| the directly
faces to the direction of the remote control receiver
Batteries are dead.| Replace batteries.
Displays ‘Et| The pipe temperature sensor is abnormaL| Check the pipe temperature sensor and related circuitry.
Displays ‘E2’.| The room temperature sensor is abnormal.| Check the room temperature sensor and related circuitry

In compliance with Directives 2012/19/0 %nd 201$/863/Eu on the restriction of the use of dangerous substances in elec trie and electronic equipment as well heir  waste disposal The symbol with the crossed dustbin shown on the package of its indicates that the product at the end service life shall be collected«s eparate waste. Therefore, any products that have reached the end life of their useful must be given to waste disposal centres specialising in separate collection of waste electrical and electronic equipment, or given back to the retailer at the time fnew purchasing similar equipment, on a one for one basis. The Adequate  eparate collection for the subsequent tart-p of treated and disposed of the equipment sent to be recycled, in a environmentally compatible way contributes to  reventing possible negative effects on the d environment and health optimises the recycling and reuse of components making up the apparatus. Abusive disposal of the product by the user involves application administrative the sanctions according to the laws

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals