Viproud FC-IR202 Digital Thermometer User Manual

June 1, 2024
Viproud

Viproud FC-IR202 Digital Thermometer

Viproud-FC-IR202-Digital-Thermometer-PRODUCT

Customer Service

Email Us

Introduction

Thank you for purchasing this Non-contact Forehead Infrared Thermometer. It is carefully developed for accurate, safe and fast temperature measurements in the forehead. Please read these instructions carefully before using this product and keep the instructions and the thermometer in a safe place.

Package Contents

No. Name Quantity
1 Infrared Thermometer 1
2 Battery (AAA, opt ional) 2
3 User M anua l 1
4 Pouch 1

Warnings and Precautions

  1. Never immerse the thermometer in water or other liquids (not waterproof). For cleaning and disinfecting, please follow the instructions in the “Care and Cleaning” section.
  2. Never use the thermometer for purposes other than those it has been intended for. Please follow the general safety precautions when using on children.
  3. Keep the thermometer away from direct exposure to the sun and keep it in a dust-free, dry area, well-ventilated place at a temperature between 50° F {10° C )-104° F(40° C ). Do not use the thermometer in high humidity environments (>95%RH).
  4. Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself. If damaged, do not attempt to repair the instrument! Please contact the dealer.
  5. This thermometer consists of high-quality precision parts. Do not drop the instrument. Protect it from severe impact and shock. Do not twist the instrument or the measuring sensor.
  6. Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity seizure, muscle pain, shivering, stiff neck, pain when urinating, etc., even in the absence of fever.
  7. Even in the absence of a fever, those who exhibit a normal temperature may still need to receive medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.
  8. This thermometer is not intended for pre-term babies or small-for-gestat ional-age babies. This thermometer is not intended to interpret hypothermic temperatures, Do not allow children to take their temperatures unattended.
  9. Use of this thermometer is not intended as a substitute for consultation with your physician or pediatrician. It is for household use only.
  10. Clean the thermometer probe after each use.
  11. Do not use the thermometer on newborns or for continuous temperature monitoring purposes.
  12. Keep out of reach of children under 12 years. Children under 12 years old must operate with an adult.
  13. Do not take a measurement while or immediately after nursing a baby. ell Patients should not drink, eat, or be physically active before/while taking the measurement.
  14. Temperature elevation may signal a serious illness, especially in adults who are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature for whom are:
    • Over 60 years of age (Fever may be blunted or even absent in elderly patients)
    • Having diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer, chemotherapy, chronic steroid treatment, splenectomy)
    • Bedridden (e.g., nursing home patient, stroke, chronic illness)
    • A transplant patient (e.g., liver, heart, lung, kidney)

Product Description

Overview

  • Infrared Thermometer measures the body temperature based on the infrared energy emitted from the forehead. Users can quickly get measurement results after properly scanning the forehead.
  • Normal body temperature is a range. The following tables show that this normal range also varies by site. Therefore, readings from different sites should not be directly compared. Tell your doctor what type of thermometer you used to take your temperature and on what part of the body.
  • Also, bear this in mind if you are diagnosing yourself.
Measuring part Measurements
Forehead temperature 97.0°F to 99.5°F (36.l°C to 37.5°C)
Ear temperature 96.4°F to 100.4°F (35.8°C to 38.0°C)
Oral temperature 95.9°F to 99.5°F (35.5°C to 37.5°C)
Rectal temperature 97.9°F to 100.4°F (36.6°C to 38.0°C)
Axillary temperature 94.5°F to 99.1°F (34.7°C to 37.3°()
  • Structure
    The thermometer consists of a shell, an LCD, a measure button, a beeper, an infrared temperature sensor, and a Microprocessor.

  • Operating Principle
    The infrared temperature sensor collects infrared energy emitted by the skin surface. After being focused by a lens, the energy is converted into a temperature reading by the thermopiles and measurement circuits.

  • Indications for use
    The Non-contact Infrared Thermometer is intended for the measurement of human body temperatures. The forehead mode is indicated for people of all ages.

Features

  • Non-Contact Design, Safe and more hygienic to use.
  • Quick measurement, less than 1 second.
  • Accurate and reliable.
  • Easy operation, one-button design.
  • Multi-functional, can measure forehead, room, milk, water, and object temperature.
  • 3S sets of memories, easy to recall.
  • Switching between mute and un-mute mode.
  • Fever alarm function, displayed in orange and red light.
  • Switching between •c and °F.
  • Auto shut-down and power-saving.

Product Structure

1. LCD display screen

2. Measure button
3. Mem (Memory Recall)
4. Mute-unmute button

(or °F/°C conversion)

5. Sensor
6. Rating label
7. Battery cover

Display Description

1. Temperature value

2. Room/Object temperature mod
3. Forehead temperature mode
4. Fahrenheit/Celsius degrees
5. Mute/Un-mute
6. Memory recall

How to Use Your Thermometer

When using the thermometer for the first time, please insert the batteries.

Press the Measure Button to Turn On the Thermometer

  • Hold the thermometer within 0-1.5 inches of the forehead and aim it at the center, start measuring with a short press of the “Measure” button, and then you can read the value.

Remarks:

Please measure forehead temperature in forehead temperature mode (the screen will show” “)

  • If the eyebrow area is covered with hair, sweat or dirt, please clean the area beforehand to improve the reading accuracy.
  • Always check if the lens is clean.
  • Always make sure the user and the thermometer will have been in the same room prior to the measurement.

Take Room/Object Temperature

  • When the thermometer is turned off, long press the”Mem” button for 5 seconds until it shows – Then press the “Measure” button to measure.
  • Keep the thermometer about 1-1.5 inches (1-3cm) away from the object. Press and release the “Measure” button in 1 second, you can read the value after hearing the beep.
  • Turnoff the thermometer, and restart it, then get back to forehead mode.

After a Measurement

  • Once the reading has been completed, remove the thermometer away from the forehead and observe the temperature.
  • After each measurement, you can enter the recall mode and query earlier temperature readings.
  • Do not hold the thermometer for a long time, because it is sensitive to the ambient temperature.
  • After each measurement, clean the temperature probe with a soft cloth, and put the thermometer in a dry and well-ventilated place.
  • You should wait at least 10 seconds between each measurement.
  • It is dangerous to make a self-diagnosis or self-treatment based on the obtained measurement results. For such purposes, please consult a doctor.

Read Your Temperature

”T” indicates a temperature reading.

In forehead mode:

  1. If 89.6’F s Ts 99.2’F {32’C s Ts 37.3’C), the green light will last for 12 seconds, with one long beep.
  2. If 99.3’F s Ts 100.3’F {37.4’C s Ts 37.9’C), the orange light will last for 12 seconds, with 3 short beeps, and the value in the LCD screen flickers, which is a warning that you may have a light fever.
  3. If 100.4″F s Ts 109.2’F (38’C s Ts 42.9’C), the red light will last for 12 seconds, with 5 short beeps, and the value in the LCD screen flickers, which is a warning that you may have a high fever.

Switching Between Mute and Un-mute

When the thermometer is turned on, keep short pressing the Mute-unmute button for 1 second to switch from un-mute to mute.

  • The mute/unmute function is switchable in the forehead mode, it is not switchable in the object/room temperature mode.
  • Un-mute is only a beep sound, not a broadcast temperature value.

Checking 35 Sets of Memory Data

  • When the thermometer is turned on, by short pressing the “Mem” button in ls to enter the memory mode, and press this button again to check the 35 sets of memories one by one. If it shows no value it will display ” “
  • The memory data will be lost when removing the batteries.

“F /’C Conversion

  • When the thermometer is turned on, keep long pressing the Mute-unmute button for 5 seconds, to change the “F/°C.

Temperature Compensation Adjustment

  • When the thermometer is turned on, press both the Mute-unmute button and Mem button together for 2-3 seconds to enter the temperature compensation mode.

  • By pressing the Mem to adjust the temperature from +0.0 °F(°C) to $2.0°F (°C).
    NOTE: All the future temperatures you are taking will be automatically added to the value you adjusted.

  • To Turn Off The unit will shut down automatically after 10#1 seconds without use. Keep pressing the Measure button for 10 seconds, it will shut down.

Caution

  • All memory records will lost when the battery is removed or reinstalled.
  • All settings will come to default when removing the battery. If the settings need to be adjusted, please power on and make the new settings.

Replace the Battery

  • Slide the battery cover off along the marked direction. Put two AAA batteries correctly into the compartment.
  • Remove the batteries if the thermometer will not be used for more than two months.

Reset the Thermometer

  • When the screen shows “–“, “Hi” or any other accuracy issues that can’t be solved, please remove the battery and reset the thermometer.

Disposal:

For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point.

Observe the local regulations for material disposal.

  • Please dispose of the device in accordance with EC Directive- WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.
  • Batteries must not be disposed of with household waste. As a consumer, you are required by law to recycle used batteries. You can recycle your old batteries at public collection points in your community or wherever batteries of the relevant type are sold.
  • The codes below are printed on batteries containing harmful substances:
    • Pb=Battery contains lead, Cd = Battery contains cadmium,
    • Hg = Battery contains mercury.
    • The batteries in this device do not contain any pollutants.

Temperature Taking Tips

  1. It is important to know each individual’s normal temperature when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal oral equivalent temperature. Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.
  2. A child’s normal temperature can be as high as 99.9°F (37.7°C) or as low as 97.0°F(36.11°C). Please note that this unit reads 0.9°F(0.5°C) lower than a rectal digital thermometer.
  3. Holding the thermometer for too long in the hand before taking a measurement can cause the device to warm up. This means the measurement could be incorrect.
  4. Patients and the thermometer should stay in steady-state room condition.
  5. Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat from the forehead area. Wait 10 minutes after cleaning before taking measurement.
  6. Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 10 minutes before taking a reading.
  7. In the following situations, it is recommended that 3-5 temperatures in the same location be taken and the highest one taken as the reading:
    • Newborn infants in the first 100 days.
    • Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.
    • When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.

Care and Cleaning

  1. Cleaning and user maintenance must not be performed by children unless supervised.
  2. Cleaning the device use an alcohol swab or cotton swab moistened with 95% alcohol to clean the thermometer casing and the measuring probe.
  3. After the alcohol has completely dried out, you can take a new measurement (minimum of 10 minutes).
  4. Ensure that no liquid enters the interior of the thermometer.
  5. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids.
  6. Take care not to scratch the surface of the LCD screen.
  7. Remove the batteries from the device before cleaning.
  8. Clean the device after use with a soft, slightly damp doth. If they are very dirty, you can also moisten the cloth with a mild soapy solution.
  9. Ensure that no water enters the device. If this happens, only use the device again once it has fully dried out.

Error and Troubleshooting

Symptom Possible Cause Description & **Solution**

Failed to power on

| The battery level is too low.| Replace with a new battery.
Polarities of the batteries are reversed.| Ensure the batteries are in the right position.
The thermometer is damaged.| Contact dealer.

The reading is   too low

| The lens of the probe is dirty.| Clean the lens with a cotton swab.
The distance of the item and the target is too far.| Ensure the thermometer measuring the forehead cente r within 1.5 inches.
You have just come from a cold environment.| Stay in a warmer room before taking a reading.
The reading is too high| You have just come from a hot environment.| Stay in an adequately cool room before taking a reading.
| The ambient temperature is not in the range.| 3 short beeps and red indicator light for 3 seconds. Take a measurement under an ambient temperature between

S0.0°F (l0°C) and 104°F (40°C).

| Memory Error.| 3 sh ort beeps and red indicator light for 3 seconds. Contact dealer.
| In forehead mode, T > 109.2°F (42.9°C).| 3 short beeps and red indicator light for 3 seconds. The measured object is not correct, please measure the body

temperature in forehead mode.

---|---|---
| 2.5V ± 3%,; power voltage

,; 2.6V± 3%.

| The battery level is low, it suggests you replace the battery, but you can

continue to use it.

| The power voltage is lower than 2.5V ± 3%.| It wil l turn off automat ically after 30

seconds. Please rep lace with a new battery.

| 3 short beeps and red indicator light for 3 seconds. “—- ” means the measurement failure.

The possible cause is as follow :

• The measurement distance is more than 1.5 inches.

• The measured temperatu re is lower than 89.6°F (32°().

  • Do not use the forehead mode to measure room/object temperature, and must wait until the beep stops completely before checking the temperature value.

  • If  not   solved, please contact the dealer.

Specifications

Product name Infrared thermometer
Power supply DCl.SV x 2

Measurement range

| For ehead: 89.6°F-109.2°F (32 .0°C-42.9°C)
Object:32°F-212°F (0°C-l00°C)
Accuracy (Laborato ­ ry)| For ehead mode| ±0.4°F/±0.2°C
Object mode| ±l.8°F/±l.0°C
Display resolu t ion| O.l°F/°C
Measuring distance| 0-1.5 inches
Automatic shutdown| 10s ± ls
Memory| 35 groups of measured tempe rature
Battery| 2• AAA
---|---
Weight & Dimension| 66.8g (without battery), 36x42x153.Smm

Operating conditions

| Operating Temperature: S0°F~104°F (l0°c~4o•q

Relative Humidity:,; 85% moisture condensation Atmospheric pressure: 70-106kPa

Storage conditions

| Storage Temperature : -4°F~B 1°F (-20°c ~ss0   C)

Relative Hum idity: ,; 95% moisture condensat ion

Device Life| 5 Years

Symbols

Symbol Description
Type BF app lied part.
MANUFACTURER
Refer to instruction manual/booklet
The marking of electrical and electronics devices according to Direct ive

2002/96/EC.

The device accessories and the packaging have to be disposed of waste correctly at the end of the usage.

Please follow Local Ordinances or Regulations for disposal.

| SERI AL NUMBER
| Batch number
| IMPORTANT

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

| 2 Protected against solid foreign objects of 12,5mm and greater; 2 If keep the thermometer in 15 degree angle, it still can prevent

the water drop.

| AUTHORISED REPRESENTATIVE IN THE EUROPEAN COMMUNITY
| Transport package shall be kept away from rain.
| Keep away from sunlight
---|---
| Fragile, handle with care
| Unique device identifier
| Date of manufacture
| Model number
| Made in China
| Medical device
| CE mark

EMC Information

IEC 60601-1-2: 2014 ME EQUIPMENT and ME SYSTEMS identification, marking and documents for Class B product. The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environ- ments and so on.

  • Warning: Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.
  • Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
  • Warning: Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
  • Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas should be used no closer than 30cm to any part of the Infrared Thermometer (FC-IR202), including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
  • If any: A list of all cables and maximum lengths of cables (if applicable), transducers and other ACCESSORIES that are replaceable by the RESPONSIBLE ORGANIZATION and that are likely to affect compliance of the ME EQUIPMENT or ME SYSTEM with the requirements of Clause7 (EMISSIONS) and Clause 8 (IMMUNITY). ACCESSORIES may be specified either generically (e.g.shielded cable, load impedance)or specifically (e.g. by MANUFACTURER and EQUIPMENT OR TYPE REFERENCE).
  • If any: The performance of the ME EQUIPMENT or ME SYSTEM that was determined to be ESSENTIAL PERFORMANCE and a description of what the OPERATOR can expect if the ESSENTIAL PERFORMANCE is lost or degraded due to EM DISTURBANCES (the def ined term “ESSENTIAL PERFORMANCE” need not be used).

Technical description:

  • All necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life.
  • Guidance and manufacturer’s declaration-electromagnetic emissions and Immunity.

Table 1

Guidance and manufacturer’s declaration – electromagnetic emissions

Emissions test| Compliance
RF emissions CISPR 11| Group 1
RF emissions CISPR 11| Class B
Harmonic emissions IEC 61000-3-2| N/A
Voltage fluctuations/ flicker emissions IEC 61000-3-3| ****

N/A

Table 2

Guidance and manufacturer’s declaration – electromagnetic immunity

Immunity Test| IEC 60601 1-2 Test level| Compliance level
Electrostatic discharge(ESD) IEC 61000-4-2| ±8 kV contact ±2 kV,

±4 kV, ±8 kV, ±15 kV air

| ±8 kV contact ±2 kV,

±4 kV, ±8 kV, ±15 kV air



Electrical fast transient

/burst IEC61000-4-4

| Power supply lines: ±2 KV input/output lines: ±1 kV lO0kHz repetition

frequency

| ****


N/A


Surge IEC6 1000-4-5

| line (s) to line (s): ±1 KV. line (s) to

earth: ±2 KV.

| ****

N/A


Voltage dips, short interruptions and voltage variations on power supply input linesIEC61000-4-11

| 0% 0.5 cycle At 0°, 45°,90°,

135°, 180°, 225°, 270° and

315° 0% 1 cycle And 70% 25/30 cycles Single phase: at 0 0% 250 cyde

| ****



N/A

Power frequency magnetic field IEC61000-4-8| 30A/m

50Hz/60Hz

| 30A/m

50Hz/60Hz


Conduced RF IEC61000-4-6

| 150KHz to 80MHz:

3Vms 6Vrms (in ISM and

amateur radio bands) 80% Am at lkHz

| ****


N/A


Radiated RF IEC61000-4-3

| lOV/m

80MHz-2,7GHz

80%AM at 1 kHz

| lOV/m

80MHz-2,7GHz

80%AM at 1 kHz

NOTE UT is the a.c. mians voltage prior to application of the test level.

Table 3

Guidance and manufacturer’s declaration-electromagnetic immunity

 | Test Frequenc.y (MHZ)| ****

Band

(MHZ)

| ****

Service

| ****

Modulation

| ****

Modulation

(W)

| ****

Distance

(M)

| IMMUNllY TEST LEVEL

(V/m)

|
---|---|---|---|---|---|---|---|---
 |  |  |  | Pulse|  |  |  |
 | 385| 380-390| TETRA400| modulation| 1.8| 0.3| 27|
 |  |  |  | 18Hz|  |  |  |
 | ****

450

| ****

430-470

| ****

GMRS4 60, FRS460

| FM±5kHz

deviation 1 kHz sine

| ****

2

| ****

0.3

| ****

28

|
Radiated RF IEC61000| 710

745

780

| ****

704-787

| ****

LTEBand 13, 17

| Pulse

modulation 217Hz

| ****

0.2

| ****

0.3

| ****

9

|
-4-3 (Test|
 |  |  | GSM800

/900, TETRA 800,

iDEN 820, CDMA850,

LTE Band 5

|  |  |  |  |
specifica-|  | 810|  |  |  |  |  |
tions for|  |  |  | Pulse|  |  |  |
ENCLO-|  | 870| 800-960| modulation| 0.2| 0.3| 28|
SURE PORT| —|  |  | 18Hz|  |  |  |
IMMUNITY

to RF

|  | 930|  |  |  |  |  |
 |  |  |  |  |  |  |
wireless

communi

| ****

1720

|  | GSM 1800;

CDMA1900;

|  |  |  |  |
cations|  |  | GSM 1900;| Pulse|  |  |  |
equip-| 1845| 1700-1990| DECT;| modulation| 2| 0.3| 28|
ment)|  |  | LTE Band| 217HZ|  |  |  |
 | 1970|  | 1,3,4,25;

UMTS

|  |  |  |  |
 |  |  | Bluetooth|  |  |  |  |
 |  |  | WLAN,| Pulse|  |  |  |
 | 2450| 2400-2570| 802.11b/g/n,| modulation| 2| 0.3| 28|
 |  |  | RFID 2450,| 217HZ|  |  |  |
 |  |  | LTE Band A|  |  |  |  |
 | ****

5500

5785

| ****

5100-5800

| ****

WLAN

_         a/n

80211

| Pulse

modulation 217HZ

| ****

0.2

| ****

0.3

| ****

9

|

Warranty and After-Sale Service

  • The device is under warranty for lifetime unlimited from the date of purchase.
  • The batteries, the packaging, and any damage caused by improper use are not covered by the warranty.
  • Excluding the following user-caused failures:
    • Failure resulting from unauthorized disassembly and modification.
    • Failure resulting from an unexpected dropping during application or transportation.
    • Failure resulting from not following the instructions in the operating manual.

Viproud

INFRARED THERMOMETER

U.S. Agent:

  • CTI U.S.Inc. Suite 230,1455 Cti U.S.Inc. Lincoln Parkway, Atlanta, Ga,30346
  • EC REPI RIOMAVIX S.L. Calle de Almansa 55, 1D, Madrid, 28039 Spain
  • SRN: ES-AR-000001202

FREQUENTLY ASKED QUESTIONS

What type of thermometer is the Viproud FC-IR202 Digital Thermometer?

The Viproud FC-IR202 Digital Thermometer is an infrared thermometer that measures temperature without direct contact.

What temperature range does the Viproud FC-IR202 Digital Thermometer cover?

The Viproud FC-IR202 Digital Thermometer can measure temperatures from 32°C to 42.9°C (89.6°F to 109.2°F).

How quickly does the Viproud FC-IR202 Digital Thermometer provide a temperature reading?

The Viproud FC-IR202 Digital Thermometer provides a reading within one second, making it suitable for quick temperature checks.

Is the Viproud FC-IR202 Digital Thermometer suitable for measuring both adults and children?

Yes, the Viproud FC-IR202 Digital Thermometer is suitable for both adults and children due to its non-contact design and quick reading speed.

Can the Viproud FC-IR202 Digital Thermometer store previous temperature readings?

Yes, the Viproud FC-IR202 Digital Thermometer can store previous readings to track temperature trends over time.

Does the Viproud FC-IR202 Digital Thermometer provide readings in both Celsius and Fahrenheit?

Yes, the Viproud FC-IR202 Digital Thermometer can switch between Celsius and Fahrenheit for user convenience.

How is the Viproud FC-IR202 Digital Thermometer powered?

The Viproud FC-IR202 Digital Thermometer is powered by two AAA batteries, which are easy to replace when needed.

Is the Viproud FC-IR202 Digital Thermometer safe to use on sensitive skin?

Yes, the Viproud FC-IR202 Digital Thermometer is non-contact, meaning it doesn't touch the skin directly, making it suitable for sensitive skin.

Does the Viproud FC-IR202 Digital Thermometer have a fever alert feature?

Yes, the Viproud FC-IR202 Digital Thermometer features a fever alert, which notifies users with a color-coded display or audible sound.

What is the accuracy of the Viproud FC-IR202 Digital Thermometer?

The Viproud FC-IR202 Digital Thermometer is accurate to within ±0.2°C (±0.4°F), ensuring reliable readings.

How is the Viproud FC-IR202 Digital Thermometer operated?

The Viproud FC-IR202 Digital Thermometer is operated with simple button controls and an easy-to-read display.

What is the best distance to hold the Viproud FC-IR202 Digital Thermometer from the forehead for accurate results?

The Viproud FC-IR202 Digital Thermometer should typically be held 1-2 inches away from the forehead for accurate measurements.

Does the Viproud FC-IR202 Digital Thermometer have an auto-shutoff feature?

Yes, the Viproud FC-IR202 Digital Thermometer automatically shuts off after a period of inactivity to conserve battery power.

Can the Viproud FC-IR202 Digital Thermometer be used for measuring object temperatures as well?

Yes, the Viproud FC-IR202 Digital Thermometer has modes to measure object temperatures like milk or bathwater.

Is the Viproud FC-IR202 Digital Thermometer suitable for clinical use?

The Viproud FC-IR202 Digital Thermometer is primarily designed for personal use but can also be used in clinical settings if needed.

VIDEO – PRODUCT OVERVIEW

DOWNLOAD THE PDF LINK:Viproud FC-IR202 Digital Thermometer User Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Viproud User Manuals

Related Manuals