guardian AC5300 Series Air Cleaning System Instructions
- June 6, 2024
- GUARDIAN
Table of Contents
- guardian AC5300 Series Air Cleaning System
- READ AND SAVE THESE INSTRUCTIONS
- PRODUCT SPECIFICATIONS AND PARTS
- CONTROLS
- REPLACEMENT PARTS
- AIR CLEANING SYSTEM
- AIR CLEANING LAYERS
- OPERATING INSTRUCTIONS
- FILTER REPLACEMENT
- CHECKING AND MAINTAINING FILTER
- INSTALLING & REMOVING UV-C BULB UV
- TROUBLESHOOTING GUIDE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
guardian AC5300 Series Air Cleaning System
READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below may result in electric shock
or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
- Read all instructions before using appliance.
- IMPORTANT – This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
- WARNING: To reduce the risk of fire or electric shock do not use with an extension cord.
- To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
- Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.
- To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
- Extreme caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.
- Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
- NEVER drop or insert any object into any openings.
- DO NOT run cord under carpeting.
- DO NOT cover cord with throw rugs, runners, or similar coverings.
- DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.
- Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
- DO NOT use outdoors.
- DO NOT place anything on top of unit.
- NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
- DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
- WARNING : To reduce the risk of fire or electric shock, do not use this purifier with any solid-state speed control device.
- WARNING: Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before replacing lamp or servicing. Replace Lamp With Lamp Model No. LB1000, Manufactured by Guardian Technologies.
- Always unplug the unit before cleaning or servicing in any way.
- CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.
CAUTION: THIS EQUIPMENT SHOULD BE INSPECTED AND CLEANED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS ON A REGULAR BASIS TO PREVENT EXCESSIVE
ACCUMULATION OF DUST PARTICLES THAT CAN RESULT IN FLASHOVER OR A RISK OF FIRE.
The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3
chamber. The product complies with the maximum allowable concentration of
ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The
Health Canada Guideline 2010 recommends that the maximum exposure limit, based
on averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed,
controlled room approximately 30 m3.
WARNING: Cancer and Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.
This product earned the ENERGY STAR label by meeting strict energy efficiency guidelines set by the U.S. EPA. Room air cleaners have demonstrated the potential for improving air quality and providing health benefits. EPA does not endorse manufacturer claims regarding the degree to which a specific product will produce healthier indoor air. The energy efficiency of this ENERGY STAR certified model is measured based on a ratio between the model’s CADR for Smoke and the electrical energy it consumes, or CADR/Watt.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In
case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup 1-866-284-4010
PRODUCT SPECIFICATIONS AND PARTS
CONTROLS
REPLACEMENT PARTS
IMPORTANT: To maintain the performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only. To Purchase Contact Customer Service
AIR CLEANING SYSTEM
- Improve your indoor air quality with your new germguardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens, and Charcoal filter to remove odors.
- UV-C light technology enhances germ-killing.
- Pre-Filter – Captures initial dust and allergen particles.
- Activated Carbon Filter – Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold.
- UV-C Light – UV-C light technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Carbon Filter are combined into one layer that attaches to the Filter.
AIR CLEANING LAYERS
OPERATING INSTRUCTIONS
BEFORE OPERATING THE AIR PURIFIER:
-
Select a firm, level and flat location for the air purifier.
• For proper air flow, locate the unit at least 1 foot from any wall or furniture.
• Make sure none of the grills are blocked. -
Plug the power cord into a 120V AC outlet.
IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.
OPERATING THE AIR PURIFIER (AC5300 SERIES):
1. Turn unit power ON. To turn OFF, press and hold button for 3 seconds.
2. Select fan speed MODE 1 – 3
1 = low, ultra quiet sleep mode
3 = high
3. Select UV-C ON or OFF using UV-C Mode Button.
Filter Replacement Indicator: The Replace HEPA light on the control panel
will illuminate and flicker indicating that it is time to replace your filter.
Replace the filter according to directions (E-7) then press and hold the UV
Mode button for 3 seconds to reset the system.
UV Bulb Replacement Indicator: The circular blue light on the front panel of the purifier will flicker when it’s time to replace the bulb. Replace the bulb according to directions (E-8), then press and hold UV Mode button for 3 seconds to reset the system.
OPERATING THE AIR PURIFIER (AC5350 SERIES):
1. Turn unit power ON.
2. Select fan speed MODE 1 – 5
1 = low, ultra quiet sleep mode
5 = high speed allergen control – Default setting is 5
3. Select UV-C ON or OFF using UV-C Mode Button.
4. TIMER: If you prefer to run the purifier for a specific number of hours, you can select between 1 and 8 hours on the display.
Filter Replacement Indicator: The Replace HEPA light on the control panel will illuminate and flicker indicating that it is time to replace your filter. Replace the filter according to directions (E-7) then press and hold the UV Mode button for 3 seconds to reset the system.
UV Bulb Replacement Indicator: The circular blue light on the front panel of the purifier will flicker when it’s time to replace the bulb. Replace the bulb according to directions (E-8), then press and hold UV Mode button for 3 seconds to reset the system.
Control Panel Beep/Sound: The sound emitted from pressing the buttons on the control panel can be turned off/on by holding the Speed button for 3 seconds.
FILTER REPLACEMENT
The Air Cleaner will beep for 30 seconds and the Replace HEPA light will flash continuously indicating that it is time to replace your filter. Replace the filter according to directions then restart the system. Depending on usage, filter will last approximately 6 months.
-
Turn off and unplug the unit.
-
Press the lock and release button and remove the rear cover from the unit.
-
Remove the used Combination Filter (Filter C) and dispose of it in the garbage
-
Insert filter system into the unit. Consult the arrow on the filter for correct installation direction.
-
Reattach the rear cover of the unit and securely latch into place.
CHECKING AND MAINTAINING FILTER
- Maintain the filter by checking it frequently.
- Depending on air quality conditions, you may need to replace it more frequently.
- Vacuum the carbon filter layer as needed to remove loose debris and dust and to help prolong the life of your filter.
- To check the status of the filter, peel back the carbon layer to expose the pleated filter.
- If the filter is no longer white and is covered in grey dust/dirt it should be replaced.
IMPORTANT: Do NOT try to wash and re-use the Combination Filter.
IMPORTANT: To maintain the performance of the air cleaner, use Guardian
Technologies GENUINE Replacement Parts only.
INSTALLING & REMOVING UV-C BULB UV
Bulb Replacement Indicator: The UV light on the display will flash when its time to replace the UV bulb.
-
Turn off and unplug unit.
Press the lock and release button and remove the rear cover from the unit. -
Remove the combination filter.
-
Use a Philips head screwdriver to remove 2 screws and detach the UV-C Metal Shield.
-
The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.
-
The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.
NOTE: Do NOT stick any foreign objects or your fingers inside of the
unit.
CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on
and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.
TROUBLESHOOTING GUIDE
PROBLEM | SOLUTION |
---|---|
Unit does not operate. | Check that the unit is plugged in. Check that filter |
is in place.
Confirm that filter is Genuine Replacement Filter Call Customer Service.
Unit shuts off unexpectedly.| Check that unit is plugged into a working electrical outlet. Check that filter is firmly in place.
Check that the Rear Cover is latched firmly in place. Call Customer Service.
No air circulating from unit.| Unplug unit. Check Pre-/Carbon and filters. Clean Pre-/Carbon Filter if necessary.
Replace filter if necessary.
Increase in noise level.| Make sure the filters are clean. Replace if
necessary.
Control buttons “beep” when pushed. (AC5350 Series)| To shut off the “beeping”
sound when buttons are pushed.
1. Press and hold the TIMER and UV buttons for 3 seconds.
2. Select ON/OFF.
‘Beeping’ will automatically be reset to ON when the unit is unplugged.
Red light is flashing.| Replace filter and reset system.
Blue ring on product is flashing.| Replace bulb and reset system.
What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of
filtered air delivered by an air purifier. CADR ratings show the effectiveness
of how efficient the air purifier is at capturing fine particles from things
like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at
suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers.
The higher the number, the faster the unit filters the air.
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of
defects in materials or workmanship commencing upon the date of the original
purchase. In order to be eligible for this Limited Warranty, an original sales
receipt or comparable substitute proof of purchase bearing the date of
original purchase is required. Refer to the original product carton or
specific product/model page on the Guardian Technologies website for warranty
length for your particular model. This warranty applies only to the original
purchaser of this product from the original date of purchase. This warranty
covers product purchased from authorized distributors only.
This warranty does not cover Guardian Technologies products that are used outside of the US and Canada as the appliance must be plugged directly into a 120V AC electrical outlet without the use of an adapter.
This warranty applies to repair or replacement of product found to be defective in materials or workmanship. This warranty does not apply to damage resulting from unusual wear, commercial, abusive, unreasonable use or supplemental damage. This warranty does not cover damage from unauthorized repairs or from any use not in accordance with the instruction manual. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.)
To submit product under warranty the complete machine must be delivered pre-
paid to Guardian Technologies LLC. Please include complete information
including: the problem, the model number of the product, the day of purchase,
and a copy of the original sales receipt along with your name, address, and
telephone (email optional). Address returns to the attention of: Repair
Department, at the address below. Additional questions or comments can be made
toll free to the number listed below.
USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to
www.guardiantechnologies.com to
register your product. We consider the registration process important to
ensuring superior service to our customers, however submitting the
registration is optional and does not affect your rights to utilize this
warranty according to the conditions stated above.
Additional copies of the instruction manual can be obtained by accessing and
printing directly from our website or calling customer service.
Guardian Technologies LLC
26251 Bluestone Blvd. • Euclid, OH 44132
1.866.603.5900
References
- Cleaning Up a Broken CFL | US EPA
- Lasko, GermGuardian, B-Air, BlueDri | Fans, Heaters, Air Purifiers – GuardianTechnologies