guardian technologies AC5350 Series Air Cleaning System Instruction Manual

June 4, 2024
guardian technologies

guardian technologies AC5350 Series Air Cleaning System

READ AND SAVE THESE INSTRUCTIONS WARNINGS Failure to comply with the warnings listed below may result in electric shock or serious injury. This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury. WARNING: THE CORDS, wIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDs, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING. (CALIFORNIA CODE OF REGULATIONS PROPOSITION 65) When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

  • Read all instructions before using appliance. IMPORTANT
  • This appliance has a polarizod plug (onc blade is wider than the other). To reduco the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
  • Do not attempt to defeat this safety feature. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. Keep the cord out of heavy traffic areas. lo avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters. lo protect against electrical hazards,
  • DO NOT immerse in water or other Iiquids.
  • Do not use near water Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the unit. Always unplug the air puriier before moving it, opening the grill, changing frlters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
  • NEVER drop or insert any object into any openings.
  • DO NOT run cord under carpeting.
  • DO NOT cover cord with throw rugs, runners, or similar coverings.
  • DO NOI route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or it it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.

READ AND SAVE THESE INSTRUCTIONS

WARNINGS

  • Failure to comply with the warnings listed below may result in electric shock or serious injury.
  • DO NOT place anything on top of unit.
  • NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit.
  • Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
  • WARNING: To reduce the risk of fire or electric shock, do not use this fan with any Solid-state speed control device.

PRODUCT SPECIFICATIONS AND PARTS

  • MODEL NUMBER.. AC5300, AC5350 Series
  • DIMENSIONS.. 9.25″ D x 7″ Wx27.5″ H
  • WEIGHT. 10.95 Ibs *ansna**** . 10.9
  • INPUT VOLTAGE. 120 V, 60Hz, 58W, 05 A BULB…5W (H) LAMP cONTAINS MERCURY Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below. www.epa.gov/cflcleanup 1-866-284-4010
  • REPLACEMENT FILTER FILTER C (FLT5000)
  • REPLACEMENT BULB LB4000

AIR CLEANING SYSTEM

Improve your indoor air quality with your new germguardian Air Cleaning System. Multiple levels of cleaning include a combination True HEPA filter that captures allergens, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing. Pre-Filter Captures initial dust and allergen particles. Charcoal Filter (aka Activated Carbon) Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold. True HEPA Filter Captures 99.99% of dust and allergens. UV-C Light UV-C light technology works with Titanium Dioxide (Ti0) to enhance the elimination of airborne germs. TiO is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets. *Pre-Filter and Charcoal Filter are combined into one layer that attaches to the HEPA Filter

AIR CLEANING LAYERS

INSTALLING & REMOVING COMBINATION FILTER

The Air Cleaner will beep for 30 seconds and the Replace HEPA light will flash continuously indicating that it is time to replace your filter. Replace the filter according to directions then restart the system. See specific model instructions (E-7/E-8). Depending on usage, filter will last approximately 6 months.

guardian-technologies-AC5350-Series-Air-Cleaning-
System-05

  1. Tum off and unplug the unit.
  2. Press the Lock & Release Button and remove the Rear Cover from the unit
  3. Remove the used combination Filter Filter C) and dispose of it in the garbage.
  4. Insert filter system into the unit. Consult the arrow on the filter for correct installation direction.
  5. Reattach the Rear Cover of the unit and securely latch into place.

OPERATING INSTRUCTIONS

BEFORE OPERATING THE AIR PURIFIER:
  1. Select a firm, level and flat location for the air purifier.
    For proper air flow, locate the unit at least 1 foot from any wall or furniture.
    Make sure none of the grills are blocked.

  2. Plug the power cord into a 120V AC outlet. IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.

OPERATING THE AIR PURIFIER (AC5300 SERIES):
  1. Turn unit power ON. To turn OFF, press and hold button for 3 seconds.
  2. Select fan speed MODE 1 – 3 1 = low, ultra quiet sleep mode 3 = high
  3. Select UV-C ON or OFF using UV-C Mode Button.

Filter Replacement Indicator: The Replace HEPA light on the control panel will illuminate and flicker indicating that it is time to replace your filter. Replace the filter according to directions (E-6) then press and hold the UV Mode button for 3 seconds to reset the system.
UV Bulb Replacement Indicator: The circular blue light on the front panel of the purifier will flicker when it’s time to replace the bulb. Replace the bulb according to directions (E-8), then press and hold UV Mode button for 3 seconds to reset the system.

OPERATING THE AIR PURIFIER (AC5350 SERIES):

1. Turn unit power ON.
2. Select fan speed MODE 1-5 1 = low, ultra quiet sleep mode 5 = high speed allergen control Default setting is 5
3. Select UV-C ON or OFF using UV-C Mode Button.
4. TIMER: If you prefer to run the purifier for a specific number of hours, you can select between 1 and 8 hours on the display.

UV Bulb Replacement Indicator: The circular blue light on the front panel of the purifier will flicker when it’s time to replace the bulb. Replace the bulb according to directions (E-8), then press and hold UV-C Mode button for 3 seconds to reset the system.
Filter replacement Indicator: The Replace HEPA light on the control panel will illuminate and flicker indicating that it is time to replace your filter. Replace the filter according to directions (E-6) then press and hold the Timer button for 3 seconds to restart the system.
Control Panel Beep/Sound: The sound emitted from pressing the buttons on the control panel can be turned off/on by holding the Speed button for 3 seconds.

INSTALLING & REMOVING UV-C BULB
  1. Remove the Rear Cover of the unit by pushing Lock & Release Button

  2. After removing the Rear Cover from the unit, remove the Combination Filter

  3. After removing the Combination Filter, use a Philips head screwdriver to remove 2 screws and detach the UV-C Metal Shield.
    guardian-technologies-AC5350-Series-Air-Cleaning-
System-06

  4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.
    guardian-technologies-AC5350-Series-Air-Cleaning-
System-08

CLEANING & MAINTAINING THE COMBINATION FILTER

The air purifier should be cleaned at least once every month and the outer Pre-/Charcoal Filter attached to the HEPA Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.

PRE-/CHARCOAL FILTER

Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt.

guardian-technologies-AC5350-Series-Air-Cleaning-
System-09

TRUE HEPA FILTER

Remove the Combination Filter from the back of unit. Remove the Pre-/Charcoal Filter to expose the HEPA filter. When the HEPA Filter turns from white to grey or black it should be replaced with a new one. If the HEPA filter is still white, it does NOT need to be replaced.
IMPORTANT: Do NOT try to wash and re-use the Combination Filter. Please contact Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement filter Replacement filter: FILTER C (FLT5000) or FILTER CPET (FLTS250PT) NOTE: The Combination Filter is one filter system. The multiple layers include: the Pre-/Charcoal Filter and the True HEPA Filter.

AIR PURIFIER

Use a clean, dry, soft cloth to wipe the external surface of the unit.
Clean Air Delivery Rate From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air. This air cleaner is suggested for use in a single, closed room up to 199 square feet. Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are dosed.
TOBACCO SMOKE: 129 This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use. Tested per ANSI/AHAM AC-1 National Standard
What is CADR? CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered a ir delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particules from things like tobacco smoke and plant pollens from the room.
NOTE: DO NOT stick any foreign objects or your fingers inside of the unit
CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.

Troubleshooting

guardian-technologies-AC5350-Series-Air-Cleaning-
System-13

LIMITED WARRANTY

To the consumer, Guardian Technologies LLC Warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. Save your original sales receipt to validate start of warranty period. Warranty is not valid without receipt. If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty does not cover unauthorized repairs. The warranty does not include unusual wear, damage resulting from accident, or unreasonable use of the product. This warranty only covers the product when used with genuine Guardian Technologies accessories. This warranty covers product that was purchased from authorized distributors. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.) The product warranty registration can be completed online at www.guardiantechnologies.com. We consider the registration process important to ensuring superior service to our customers, however submitting the warranty registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above. To submit product under warranty the complete machine must be delivered pre-paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.
Guardian Technologies LLC 26251 Bluestone Blvd. Euclid, OH 44132
1.866.603.5900 – www.guardiantechnologies.com This warranty can be registered online at www.guardiantechnologies.com Additional copies of the instruction manual can be obtained by accessing and
printing directly from our website or calling customer service.
Check out our on-line Filter Reminder and Replacement program. www.guardiantechnologies.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

guardian technologies User Manuals

Related Manuals