DOMUS LINE 3478600 LAB LED Light Installation Guide

June 6, 2024
DOMUS LINE

**LAB

http://www.domusline.com/installation_manuals/3478600_LAB_r6.pdf
INSTALLATION MANUAL
DOMUS LINE Srl
Via Maestri del Lavoro, 1
33080 PORCIA PN Italy**

| Protection class III device. Power must be supplied by a safe power supply.
---|---
| Photobiological safety: The device belongs to the risk 0 group (EXEMPT) in accordance with EN62471.
****| The product must be disposed of separately from urban waste, delivering it to the collection centers established by the prevailing standard. The adequate sorted waste collection contributes to preventing negative effects on the environment and health and favors reuse and/or recycling
materials. Incorrect disposal of the product implies the application of the administrative sanctions envisaged by the prevailing regulation.
| Device only for indoor installation.
| Recessed luminaire that can be abutted against normally flammable materials and can be covered in normal use.

Fig.1

Fig.2

Fig.3

INSTALLATION MANUAL

WARNING:
Safety is guaranteed if these instructions are followed and therefore they must be kept. Installation may require the involvement of qualified personnel. Before proceeding with the installation of the device ensure that the environmental conditions are in compliance with and suitable for the product characteristics. Before any operation on the device
disconnect mains power.
INSTALLATION:

  • Diagram 1, 2, and 3 show the LAB installation examples. Text is indicative because it may vary according to the application and material included in the installation plan.
    The two examples differ for the cable outlet hole positions. However, it is also possible to place the hole in other positions, depending on the customer’s requirement, and according to the type of application.

  • LAB can be installed using the power cable in axial (Diagram 1) or radial (Diagram 2) position with respect to the assembly plan. For installations with the power cables in an axial position, a hole measuring ø ≥ 8mm must be drilled, as shown in the example in Diagram 1.

  • For installations with the power cables in an axial position, a hole must be drilled based on the assembly plan measuring ø ≥ 8mm, as shown in the example in Diagram 2. In terms of specific requirements, it is possible to place the power cable outlet hole in other positions, provided they do not affect the integrity of the cable and/or connector installed on it.

  • Feed the power cable (A) into the hole and install the lighting profile by applying light pressure until it is seated as shown in Diagram 4,5.

  • Position the anti-glare eyelid (B) so that the beam of light is directed towards the inside of the compartment.

  • For the installation of LAB IR in rooms with doors whose finish is reflective white, gloss, or mirror, or on surfaces with non-matte finishes, the values ​​reported in Table 1 (T1) may vary. Therefore, we recommend a preliminary functionality test be conducted before the final installation of the product.

CONNECTING THE LUMINAIRE TO THE CONVERTER:

  • Connect the LAB equipment to one safety converter only with a constant 24Vdc voltage (supplied separately) and with output at least 10% higher than the total load. For the calculation of the total load, refer to the data plate printed on the product label.

LAB is a switchless component; therefore, it must be switched on using a separate switch.

  • If it is necessary to connect more than one device to the power supply, ensure that the total sum of the power absorbed by the luminaires (refer to the data indicated on the nameplate of the product label), does not exceed the maximum permitted by the converter.
  • DOMUS Line guarantees the product only if supplied with its own power supply converter.

HOW THE LAB IR OPERATES (IR sensor) Diagram 6
The luminaire is simply switched on with the opening of the door that is positioned in front of the sensor (C). The luminaire is switched off 10 seconds after the door is closed. The luminaire has a safety program that switches the LAB IR off after 2 hours of continuous operation with the door open.
WARNING: – This luminaire must be connected directly to the electric power supply and must never be connected downstream of other electronic switches, be positioned near electromagnetic sources, or be exposed to light beams.
WARNING:
The Led MODULE, the power supply cable, or any switch used, are not replaceable, therefore in case of damage, the device must be entirely substituted.
WARRANTY:
The warranty on the device is valid only if powered by a power supply provided by DOMUS Line. The warranty’s general terms and conditions for this device are available at www.domusline.com
CAUTION
ONLY SUITABLE FOR DRY LOCATION
USE ONLY 24Vdc CLASS 2 POWER UNIT

DOMUS LINE Srl
Via Maestri del Lavoro, 1
33080 PORCIA PN Italy

phone 0039 0434 595911
fax 0039 0434 923345
e-mail info@domusline.com
website www.domusline.com

Ref. 3478600_r6

Documents / Resources

| DOMUS LINE 3478600 LAB LED Light [pdf] Installation Guide
3478600 LAB LED Light, 3478600, LAB, LED Light
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

DOMUS LINE User Manuals

Related Manuals