DOMUS LINE 3477600 DIVA collection LED Light Installation Guide
- June 6, 2024
- DOMUS LINE
Table of Contents
DIVA collection¹
SUNCITY collection¹
http://www.domusline.com/installation_manuals
Protection class III device. Power must be supplied by a safe power supply.
Photobiological safety: The device belongs to the risk 0 group (EXEMPT) in
accordance with EN62471.
The product must be disposed of separately from urban waste, delivering it to
the collection centers established by the prevailing standard. The adequate
sorted waste collection contributes to preventing negative effects on the
environment and health and favors reuse and/or recycling materials. Incorrect
disposal of the product implies the application of the administrative
sanctions envisaged by the prevailing regulation.
The device is only for indoor installation.
Fig 1
Fig 2
Fig.3
Fig.4
Fig.5
Fig.6
Fig.7
Fig.8
INSTALLATION MANUAL
¹ This installation manual contains instructions valid for all configurations
of the DIVA-SUNCITY device
WARNING:
Safety is guaranteed if these instructions are followed and therefore they
must be kept. Installation may require the involvement of qualified personnel.
Before proceeding with the installation of the device ensure that the
environmental conditions are in compliance with and suitable for the product
characteristics. Before any operation on the device disconnect mains’ power.
CONFIGURATION:
Instructions for installation and use contained in this manual are valid for
several configurations of the DIVA-SUNCITY device, for which there are
differences. The DIVA-SUNCITY TLD (TouchLed-Dimmer) model refers to the
configuration of the device that includes a dimmable electronic switch. The
DIVA-SUNCITY IFR (PIR Sensor) model refers to the configuration of the device
that includes an electronic presence detecting sensor.
The DIVA-SUNCITY TLDM and DIVA-SUNCITY IRFM models integrate an electronic
switch with the MASTER function for the connection of SLAVE devices.
The parts of the installation and use manual common to all models relate to
the DIVA-SUNCITY model or the configuration of the device that does not
incorporate a switch or sensor.
INSTALLATION:
– Pictures 1, 2, and 3 represent some examples of installation of the DIVA-
SUNCITY. The quotas are indicative because they can change according to the
application and to the material from which the plan of installation is
composed. The two examples differentiate themselves for the position of the
exit hole of the cable, nevertheless, it is possible to make this hole also in
other positions according to the demand of the customer and to the type of
application.
– The DIVA-SUNCITY can be installed using the lighting profile power cable in
axial (figure 1) or radial (figure 2) position with respect to the assembly
plan. For installations with the power cord in an axial position to drill hole
diameter of ø ≥ 8mm for TLD, IFR, SLAVE models and diameter ø ≥ 9mm for TLDM
and IFRM models as in the example shown in Figure 1. For installations with
the power cord in radial position to drill a hole on the ø ≥ 8mm mounting plan
for the TLD, IFR, SLAVE models and diameter ø ≥ 9mm for TLDM and IFRM models
as shown in the example in Figure 2. In terms of specific requirements, it is
possible to drill the power cable outlet hole in other positions, provided
they do not affect the integrity of the cable and/or connector installed on
it.
– Feed the power cable (A) into the hole and install the lighting profile by
applying light pressure until it is seated in the recess, as shown in figures
4,5,6.
Do not make any pressure on the IFR sensor to avoid damage of it.
ATTENTION: Detection field must not be obstructed by shelves or object
positioned too close of the sensor (fig.7)
The configurations DIVA-SUNCITY TLDM and DIVA-SUNCITY IFRM integrate an
electronic switch with the MASTER function.
– DIVA-SUNCITY IFRM can control a maximum of 24Watts at 12Vdc and 48Watts at
24Vdc including the power of the device.
– DIVA-SUNCITY TLDM can control a maximum of 30Watts at 12Vdc and 60Watts at
24Vdc including the power of the device.
CONNECTING THE DEVICE TO THE POWER SUPPLY
– Connect the equipment to one safety converter only with constant voltage
(supplied separately) and with output at least 10% higher than the total load.
For the calculation of the total load, refer to the data plate printed on the
product label.
The DIVA-SUNCITY SLAVE (B) is a switch-free instrument, then it must be turned
on via a remote switch, that can be placed on the DIVASUNCITY TLDM-IFRM (wired
in the MASTER version) as shown in figure 4,5 or it can be assigned to a
separate switch connected to the primary of the converter, or to a remote
socket as shown in figure 6.
DOMUS LINE Srl
Via Maestri del Lavoro, 1
33080 PORCIA PN Italy
phone 0039 0434 595911
fax 0039 0434 923345
e-mail info@domusline.com