DOMUS LINE 3477600 DIVA collection LED Light Installation Guide

June 6, 2024
DOMUS LINE

DIVA collection¹
SUNCITY collection¹

DOMUS LINE 3477600 DIVA collection LED Light - qr codehttp://www.domusline.com/installation_manuals

Protection class III device. Power must be supplied by a safe power supply.
Photobiological safety: The device belongs to the risk 0 group (EXEMPT) in accordance with EN62471.
The product must be disposed of separately from urban waste, delivering it to the collection centers established by the prevailing standard. The adequate sorted waste collection contributes to preventing negative effects on the environment and health and favors reuse and/or recycling materials. Incorrect disposal of the product implies the application of the administrative sanctions envisaged by the prevailing regulation.

The device is only for indoor installation.

DOMUS LINE 3477600 DIVA collection LED Light - Fig 1

Fig 1

DOMUS LINE 3477600 DIVA collection LED Light - Fig 2

Fig 2

DOMUS LINE 3477600 DIVA collection LED Light - Fig 3

Fig.3

DOMUS LINE 3477600 DIVA collection LED Light - Fig 5

Fig.4

DOMUS LINE 3477600 DIVA collection LED Light - Fig 4

Fig.5

DOMUS LINE 3477600 DIVA collection LED Light - Fig 6

Fig.6 DOMUS LINE 3477600 DIVA collection LED Light - Fig
7

Fig.7

DOMUS LINE 3477600 DIVA collection LED Light - Fig 8 Fig.8

INSTALLATION MANUAL

¹ This installation manual contains instructions valid for all configurations of the DIVA-SUNCITY device
WARNING:
Safety is guaranteed if these instructions are followed and therefore they must be kept. Installation may require the involvement of qualified personnel. Before proceeding with the installation of the device ensure that the environmental conditions are in compliance with and suitable for the product characteristics. Before any operation on the device disconnect mains’ power.

CONFIGURATION:
Instructions for installation and use contained in this manual are valid for several configurations of the DIVA-SUNCITY device, for which there are differences. The DIVA-SUNCITY TLD (TouchLed-Dimmer) model refers to the configuration of the device that includes a dimmable electronic switch. The DIVA-SUNCITY IFR (PIR Sensor) model refers to the configuration of the device that includes an electronic presence detecting sensor.
The DIVA-SUNCITY TLDM and DIVA-SUNCITY IRFM models integrate an electronic switch with the MASTER function for the connection of SLAVE devices.
The parts of the installation and use manual common to all models relate to the DIVA-SUNCITY model or the configuration of the device that does not incorporate a switch or sensor.

INSTALLATION:
– Pictures 1, 2, and 3 represent some examples of installation of the DIVA- SUNCITY. The quotas are indicative because they can change according to the application and to the material from which the plan of installation is composed. The two examples differentiate themselves for the position of the exit hole of the cable, nevertheless, it is possible to make this hole also in other positions according to the demand of the customer and to the type of application.
– The DIVA-SUNCITY can be installed using the lighting profile power cable in axial (figure 1) or radial (figure 2) position with respect to the assembly plan. For installations with the power cord in an axial position to drill hole diameter of ø ≥ 8mm for TLD, IFR, SLAVE models and diameter ø ≥ 9mm for TLDM and IFRM models as in the example shown in Figure 1. For installations with the power cord in radial position to drill a hole on the ø ≥ 8mm mounting plan for the TLD, IFR, SLAVE models and diameter ø ≥ 9mm for TLDM and IFRM models as shown in the example in Figure 2. In terms of specific requirements, it is possible to drill the power cable outlet hole in other positions, provided they do not affect the integrity of the cable and/or connector installed on it.
– Feed the power cable (A) into the hole and install the lighting profile by applying light pressure until it is seated in the recess, as shown in figures 4,5,6.
Do not make any pressure on the IFR sensor to avoid damage of it.
ATTENTION: Detection field must not be obstructed by shelves or object positioned too close of the sensor (fig.7)
The configurations DIVA-SUNCITY TLDM and DIVA-SUNCITY IFRM integrate an electronic switch with the MASTER function.
– DIVA-SUNCITY IFRM can control a maximum of 24Watts at 12Vdc and 48Watts at 24Vdc including the power of the device.
– DIVA-SUNCITY TLDM can control a maximum of 30Watts at 12Vdc and 60Watts at 24Vdc including the power of the device.
CONNECTING THE DEVICE TO THE POWER SUPPLY
– Connect the equipment to one safety converter only with constant voltage (supplied separately) and with output at least 10% higher than the total load. For the calculation of the total load, refer to the data plate printed on the product label.
The DIVA-SUNCITY SLAVE (B) is a switch-free instrument, then it must be turned on via a remote switch, that can be placed on the DIVASUNCITY TLDM-IFRM (wired in the MASTER version) as shown in figure  4,5 or it can be assigned to a separate switch connected to the primary of the converter, or to a remote socket as shown in figure 6.

DOMUS LINE Srl
Via Maestri del Lavoro, 1
33080 PORCIA PN Italy
phone 0039 0434 595911
fax 0039 0434  923345
e-mail info@domusline.com
website www.domusline.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

DOMUS LINE User Manuals

Related Manuals