Warmup KW-STATH Konekt Wireles Thermostat with Humidity Sensor Instruction Manual

June 6, 2024
Warmup

Warmup KW-STATH Konekt Wireless Thermostat with Humidity Sensor

View all Warmup thermostat manual

Information about this manual
This manual should be read carefully before commencing the operation of your Kontakt wireless product. Always retain the product manuals for future use.
Symbols used: Hazard indication Important information

Hazard information: Do not open the device except as instructed by the installation and operation manual. It does not contain any user-serviceable components.
The device is suitable for indoor use only. It must not be exposed to moisture, vibrations, mechanical loads, or temperatures outside of its rated values. For safety and licensing reasons (CE/UKCA), unauthorized change and/or modification of the device(s) is not permitted.
The device and its packaging are not toys; do not allow children to play with them. Small components such as batteries and packaging preset a risk of choking or suffocation. Using the device, in any way or for any purpose, other than those described in their installation and operation manuals invalidates any warranty or liability.
This device is intended for use in residential, business, and commercial properties only.
This device does not require product-specific maintenance. To clean, use a soft, clean, and lint-free cloth. To remove more stubborn marks, dampen the cloth with warm water. Do not use detergents or chemicals on the devices.

Function and device overview
The thermostat offers precise time and temperature control of floor heating or radiator systems when combined with the Wiring Centre or RVs. The thermostat measures both temperature and humidity in a room.
Due to the thermostat being battery operated it can be mounted anywhere in the room using the self-adhesive strips or screwed into the wall with the supplied clip-on frame.

Device overview:

  • Clip-on frame
  •  Thermostat
  •  Display
  •  System button
  • Pairing button and LED)
  •  Rotary button
  • Mounting plate

Display overview:

Set/actual temperature Humidity Condensation Warning Open window symbol Low Battery Radio transmission Boost function Manual operation Schedule mode Holiday mode Heating Cooling Operating lock Setpoint temperature.

General system information
The thermostat is part of the Warmup Wireless System. Devices in the Kontakt Wireless System system can be easily paired and set up through the Kontakt Wireless Smart Hub using the Kontakt App. All functions of the Kontakt Wireless System are described in detail in the User Guide. The User Guide and Online manuals for all other Kontakt Wireless devices are available on www.warmup.co.uk

Start-up

Pairing device
The thermostat can be paired seamlessly to the Kontakt Wireless Smart Hub (KW- UKHUB). To pair devices to the Smart Hub please download the Kontakt app.

Pairing to the Smart Hub: The Smart Hub must be set up via the Kontakt App before any other devices can be added to your system. For further information, refer to the Smart Hub operating manual.
If you have already connected the thermostat to another Wireless device, you MUST restore its factory settings first before you can connect it to the Smart Hub (see section 10)

Step 1 – Select Pairing from the Kontakt App

Warmup-KW-STATH-Konekt-Wireles-Thermostat-with-Humidity-
Sensor-3

Step 2 – Remove insulation strip & insert batteries

  • Remove the thermostat (B) from the frame.
  • Turn the thermostat around and remove the insulation strip from the battery compartment. Pairing mode will be activated.
  •  The pairing mode will remain active for 3 minutes.

Your device will automatically appear in the Kontakt App. To confirm, scan the QR code attached to the device or alternatively enter the last four digits of the device number (SGTIN) in the App. Give the device a name and allocate it to a room.

NOTE: If the pairing was successful, the LED will turn green. The device is now ready for use. If the LED turns red you will have to try pairing the device again. You can manually start pairing mode for another 3 minutes by pressing the system button once.
Once the thermostat has successfully paired to the Smart Hub, programming of the device or changes to device settings must be done through the Kontakt app. If required, you can quickly switch between manual or program mode on the thermostat by pressing and holding the Rotary button for 2 seconds.

Mounting : Choose a location for the thermostat. It should not be beside a window/door, in direct sunlight, or above another heat-generating device (e.g. radiator or TV). The surface the thermostat is being applied to should be clean and dust-free to ensure long-term adherence.

Adhesive strip mounting: Fix the adhesive strips to the back of the mounting plate . Ensure that the clips on the mounting plate can clip into the openings on the wall thermostat. Remove the protective film from the adhesive strips and press the thermostat into the wall plate.

Mounting with screws: Make sure that there are no electrical cables or pipes at the chosen thermostat location. For masonry walls, drill two 5 mm holes and insert the wall plugs provided. For stud walls, drill 1.5 mm pilot holes.

  •  Use screws and plugs to fasten the mounting plate to the wall
  •  Attach the clip-on frame to the mounting plate.
  • Push the thermostat into the clip-on frame. Ensure the arrow on the plate is pointing upwards.

Mounting on back boxes: The thermostat can be mounted onto new or existing back boxes using the screws provided. If installing onto an existing back box there may still be existing cables that must be made safe first. This must be done by a qualified electrician.
If the backbox is metallic it will reduce RF signal strength passing through it. Such a back box must not be connected to the earth.

Configuration menu: Programming the thermostat or changing its settings must be done through the Kontakt app.

Configuration menu

6.1| | Automatic mode
6.2| | Manual operation
6.3| | Holiday mode
6.4| | Operating lock
6.5| | Programming a heating schedule
6.6| | Date and time
6.7| | Offset temperature
6.8| | Selecting the desired temperature display
6.9| | Configuring the floor heating actuator
6.10| | Communication test

Automatic operation
In automatic mode, the temperature is controlled in accordance with your set heating schedule. Any manual overrides will be activated until the next change in the heating schedule.

Manual operation
In manual mode, you can adjust the target temperature you would like the thermostat to achieve. The target temperature can be set manually using the Rotary button on the thermostat or through the app. This temperature remains active until the next manual change.
To switch between automatic and manual operation press and hold the rotary button for 2 seconds.

Holiday Mode
Holiday mode allows you to maintain a constant temperature for a certain period, e.g. during your holidays.

Operating lock
The operation of the device can be locked to prevent settings from being changed.

Optimum start/stop function
Turns the heating on at just the right time to achieve your target temperature when you scheduled. If required this can be switched off through the app.

Offset Temperature
As the temperature is measured on the thermostat, the temperature distribution can vary throughout a room. To adjust this, a temperature offset of ±3.5°C can be set. If a nominal temperature of e.g. 20 °C is set but the room only reaches 18°C, an offset of -2.0°C may need to be set.

Boost Function
This will fully open the radiator valves of any eTRVs assigned to the same room to quickly heat the room. The boost will last for 5 minutes and can be activated by pressing the menu/boost button or through the app.
Through the app, you can amend the boost duration from 5 – 30 mins. The Boost function works with eTRV’s only. This function will not work when paired with an underfloor heating system.

Replacing batteries
If the symbol for low batteries ( ) appears in the display or in the app, replace it with two new LR03/micro/AAA batteries.
Once the batteries have been inserted, the thermostat will perform a self- test/restart. The LED will indicate that initialization is complete by lighting up orange and then green

Troubleshooting

Low batteries
Provided there is enough voltage, the thermostat will still operate. Depending on the load, it may still be possible to send commands. If the voltage drops too far during a command, the low battery symbol ( ) and error code will be displayed on the device (see section 8.4). In this instance, the batteries must be replaced.

Command not confirmed
If at least one device does not accept a command, the LED (B) will light up red. This may be caused by radio interference (see section Other possible issues may be:

  • The device cannot be reached.
  •  The device is unable to execute the command (load failure, mechanical block, etc.).
  •  The device is defective.

Duty cycle
The duty cycle is a legally regulated limit of the transmission time of devices in the 868 MHz range. The aim of this regulation is to safeguard the operation of all devices working in the 868 MHz range. In the 868 MHz frequency range we use, the maximum transmission time of any device is 1% of an hour (i.e. 36 seconds in an hour). Devices must cease transmission when they reach the 1% limit until this time restriction comes to an end. Warmup devices are designed and produced with 100% conformity to this regulation. During normal operation, the duty cycle is not usually reached. However, intensively repeated device pairing processes may mean that this limit is reached in isolated instances during commissioning.
IMPORTANT: If the duty cycle limit is exceeded, the device may stop working for a brief period. The device will start working normally again after a short period (max. 1 hour).

Error codes and flashing sequences

Flashing code Meaning Solution
Battery symbol ( ) Battery low Replace the thermostat batteries
Antenna symbol ( ) flashing Communication problem with SmartHub or connected
device Check the connection with the SmartHub or the connected devices.
Flashing humidity symbol ( ) Humidity limit (60 %) in the room is exceeded

Ventilate the room, if

required.

Lock symbol ( )| Operating lock activated| Deactivate the operating lock in the app.
Short orange

flashing

| Radio transmission/ attempting to transmit/ configuration data is transmitted| Wait until the transmission is completed.
1x long green light| Transmission confirmed| You can continue operation.
1x long red light| Operation failed| Please try again
Short orange flashing (every 10 s)| Pairing mode active| Enter the last four numbers of the device serial number

to confirm

Short orange light (after green or red

confirmation)

| Batteries empty| Replace the batteries
1x long red light| Transmission failed or duty cycle limit is reached| Please try again
6x long red

flashing

| Device defective| Have a look at your app for error message or contact Warmup.
1x orange and 1 x green lighting (after inserting batteries)| Test display| Once the test display has stopped, you can continue.

Restore factory settings

The factory settings of the device can be restored. The device will automatically reconnect to the system and redownload its settings unless it is deleted within the Kontakt App first.

Warmup-KW-STATH-Konekt-Wireles-Thermostat-with-Humidity-
Sensor-8

  •  Open the battery compartment.
  • Remove a battery.
  •  Re-insert the battery while pressing and holding the system button  until the device LED starts to flash orange
  •  Release the system button and then press and hold the system but again until the orange flashing changes to green.
  • Release the system button to finish.

The device does not require any specific maintenance other than replacing the battery when necessary. To clean, use a soft, clean, and lint-free cloth. To remove more stubborn marks, dampen the cloth with warm water. Do not use detergents or chemicals on the devices.

General information about radio operation : Radio transmission is performed on a non-exclusive RF channel, which means that there is a possibility of interference occurring. Interference can also be caused by switching operations, electrical motors, or defective electrical devices.

The range of transmission within buildings can differ greatly from that available in the open air. Besides the transmitting power and the reception characteristics of the receiver, environmental factors such as humidity in the vicinity have an important role to play, as do on-site structural/screening conditions.

Declaration of Conformity: Warmup hereby declares that the Warmup Wireless radio equipment is compliant with RED Directive 2014/53/EU and Radio Equipment Regulations 2017. Please scan the QR Code for the Declaration of Conformity.

Instructions for Disposal: Do not dispose of the device(s) with regular domestic waste! Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive.

Technical specifications

Warmup konekt Wireless Thermostat

Warmup konekt Wireless Thermostat

Product Code| KW-STATH
Supply voltage| 2x 1.5 V LR03/micro/AAA
Current consumption| 50 mA max.
Battery life| 2 years (typ.)
IP Rating| IP20
Ambient temperature| 0 to 35 °C
Dimensions (W x H x D)| 55 x 55 x 23.5 mm / 86 x 86 x 25 mm (incl. frame)
Weight| 100 g (incl. batteries)
Radio frequency band| 868.3 MHz / 869.525 MHz
Maximum radiated power| 10 dBm max.
Receiver category| SRD category 2
Typ. open area RF range| 250 m
Duty cycle| < 1 % per h/< 10 % per h
Software class| Class A
Method of operation| Type 1
Degree of pollution| 2

Warranty
Warmup plc warrants these product(s), to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either; Return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or contact Warmup. Warmup will determine whether the product should be returned or replaced. This warranty does not cover removal or re-installation costs and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation, or damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above.
This Warranty does not affect your statutory rights.

https://thermostat.guide/warmup/warmup-kw-stath-konekt-wireles-thermostat- instruction-manual/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals