telldus 313510 Z-Wave Smart Plug With Energy Meter User Guide

June 6, 2024
TELLDUS

telldus 313510 Z-Wave Smart Plug With Energy Meter

Include the device in Telldus Live

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-2 telldus-313510-Z-Wave-Smart-Plug-With-Energy-
Meter-4

Follow the built-in wizard

Control the device in Telldus Live

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-6

live.telldus.com

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-7

Control the device manually

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-8

Edit the device

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-9

live.telldus.com

Exclude the device

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-11 telldus-313510-Z-Wave-Smart-Plug-With-Energy-
Meter-14

Technical specifications

  • Product Name Telldus Z-Wave Mini Plugin Switch
  • Type Number . . . . . . . . . . . . . . . TZWP-102
  • Function On/Off, Energy Meter, Surge Protection
  • Voltage . . . . . . . . . . . . . . . . . .230V~ 50Hz
  • Input Current . . . . . . . . . . . . . . . . . Max 8A
  • Max Load. . . . . . . . . . . . . . 1800W Resistive
  • Surge Protection . . . . . . . . . . . . . . . >1500V
  • Energy Metering Accuracy <100W . . . . . <±2W
  • Energy Metering Accuracy >100W . . . . . <±2%
  • Operating Ambience. . . 0°C–25°C; 5%–75% RH
  • Button Function . . Include/Exclude/Power/Reset
  • IP Class . . . . . . . . . . . . . . . . . . . . . . . IP20
  • Protocol. . . . . . . . . . . . . . . . . . . . . Z-Wave
  • Chip Version . . . . . . . . . . . . .500 Plus Series
  • Frequency . . . . . . . . . . . . . 868.42MHz (EU)
  • Frequency range . . . . . . . .868.0-868.6MHz & 869.7-870.0MHz
  • Transmitting Range . . . . . up to 30m (open air)
  • Pollution Degree . . . . . . . . . . . . . . . . . . . 2
  • Maximum RF Output Power . . . . . . . . . 1dBm
  • Rated Impulse Withstand Voltage. . . . . . 2.5KV
  • Duty-type . . . . . . . . . . . . S1, Continuous duty
  • Number of Operating Cycles . . . . . . . . .10000
  • Circuit Disconnection . . . Micro-disconnection
  • Glow-wire Temperature . . . . . . . . . . . .650°C
  • Non-replaceable Built-in Protection . . .Thermal Fuse 10A 84°C
  • PTI . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
  • Cooling Condition . Not required forced cooling
  • Type of Connection and Load Single Pole Single
  • Load . . . . . . . . . . (single pole disconnection)
  • Test Condition. Maximum rated resistive current

Do not connect after each other. Not to be used in direct sunlight.
Download complete technical manual and find more useful information at telldus.com
www.telldus.com
support.telldus.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals