telldus 313510 Z-Wave Smart Plug With Energy Meter User Guide

June 6, 2024
TELLDUS

telldus 313510 Z-Wave Smart Plug With Energy Meter

Include the device in Telldus Live

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-2 telldus-313510-Z-Wave-Smart-Plug-With-Energy-
Meter-4

Follow the built-in wizard

Control the device in Telldus Live

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-6

live.telldus.com

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-7

Control the device manually

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-8

Edit the device

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-9

live.telldus.com

Exclude the device

telldus-313510-Z-Wave-Smart-Plug-With-Energy-Meter-11 telldus-313510-Z-Wave-Smart-Plug-With-Energy-
Meter-14

Technical specifications

  • Product Name Telldus Z-Wave Mini Plugin Switch
  • Type Number . . . . . . . . . . . . . . . TZWP-102
  • Function On/Off, Energy Meter, Surge Protection
  • Voltage . . . . . . . . . . . . . . . . . .230V~ 50Hz
  • Input Current . . . . . . . . . . . . . . . . . Max 8A
  • Max Load. . . . . . . . . . . . . . 1800W Resistive
  • Surge Protection . . . . . . . . . . . . . . . >1500V
  • Energy Metering Accuracy <100W . . . . . <±2W
  • Energy Metering Accuracy >100W . . . . . <±2%
  • Operating Ambience. . . 0°C–25°C; 5%–75% RH
  • Button Function . . Include/Exclude/Power/Reset
  • IP Class . . . . . . . . . . . . . . . . . . . . . . . IP20
  • Protocol. . . . . . . . . . . . . . . . . . . . . Z-Wave
  • Chip Version . . . . . . . . . . . . .500 Plus Series
  • Frequency . . . . . . . . . . . . . 868.42MHz (EU)
  • Frequency range . . . . . . . .868.0-868.6MHz & 869.7-870.0MHz
  • Transmitting Range . . . . . up to 30m (open air)
  • Pollution Degree . . . . . . . . . . . . . . . . . . . 2
  • Maximum RF Output Power . . . . . . . . . 1dBm
  • Rated Impulse Withstand Voltage. . . . . . 2.5KV
  • Duty-type . . . . . . . . . . . . S1, Continuous duty
  • Number of Operating Cycles . . . . . . . . .10000
  • Circuit Disconnection . . . Micro-disconnection
  • Glow-wire Temperature . . . . . . . . . . . .650°C
  • Non-replaceable Built-in Protection . . .Thermal Fuse 10A 84°C
  • PTI . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
  • Cooling Condition . Not required forced cooling
  • Type of Connection and Load Single Pole Single
  • Load . . . . . . . . . . (single pole disconnection)
  • Test Condition. Maximum rated resistive current

Do not connect after each other. Not to be used in direct sunlight.