PNI CT60 Wireless Thermostat User Manual
- June 6, 2024
- PNI
Table of Contents
Wireless thermostat
Wireless thermostat
PNI CT60 wireless thermostat
VIEW ALL PNI THERMOSTAT MANUAL
Introduction
This thermostat starts and stops the central heating system based on a temperature limit and a preset time period.
Special warnings
As the product must be connected to a 230V power supply and to heating equipment, the installation must be carried out only by qualified personnel, in order to avoid irreparable damage to the product or the heating equipment to which it is connected. Also, the first configuration of the equipment should be performed by qualified personnel.
Technical specifications
Transmitter power supply | 2 x AAA batteries 15.V |
---|---|
Receiver power supply | 230VAC, max. 10A |
Frequency | 868 MHz |
The interval of set temperature | +5°C ~ +35°C |
Interval of displayed temperature | 0°C ~ +50°C |
Display | Yes, backlighted |
Sensor | NTC 3950, 10KOhm@25°C |
Accuracy | ±0.1°C |
Step | 0.5°C |
Temperature measurement unit | Only Celsius degrees |
Water protection class | IP30 |
Housing | ABS with fireproof standard UL94-5 |
Installation instructions
The thermostat can be mounted in 2 ways: on the table or on the wall with the help of the brackets included in the package.
Description of keys and icons
Pairing transmitter and receiver
Note: the two units come paired from the factory. Make the pairing procedure
only if there are communication problems.
Long press the pairing button on the receiver unit.
LED 1 flash frequently.
Turn off the transmitter unit by pressing the key.
Press and hold the MENU key on the transmitter unit until the pairing code
appears on the display (for example FF FF 0). Immediately press the ▲ key.
Another code will flash on the screen. If the pairing was successful, the code
on the screen will disappear and LED 1 (green)will turn off. Turn on the
transmitter unit. If the set temperature is higher than the room temperature,
the transmitter unit will send an RF signal to the receiver unit, which, in
turn, will send an ON command to the boiler. In this situation, LED 1 (red)
will remain lit.
Set the time and day of the week
Hold down the MENU key for 3 seconds. The minute indicator will flash. Use the
▲ and ▼ keys to reach the desired value. Briefly press the MENU key to confirm
and move to the time setting. The time indicator will flash. Use the ▲ and ▼
keys to reach the desired value. Briefly press the MENU key to confirm and
move to the day of the week setting (1 to 7). Press the MENU key to exit.
Operation mode setup
Briefly press the MENU key to set the operation mode: Scheduled, Manual or
Holiday.
In Scheduled mode, the PRG icon appears on the right side of the screen as in
the image below:
In Manual mode, only the time, day and temperature are displayed on the screen:
In Holiday mode (Economic), on the right side of the screen appears an icon in the form of a suitcase as in the image below:
Scheduled mode
Schedule by day
Briefly press the MENU key to set the Scheduled operating mode.
Long press the PRG key for 3 seconds to enter the programming menu.
The time and temperature will flash on the screen.
Each time you press the PRG key, the selected value will be confirmed and you
will move on to the next setting. After setting the time and the temperature
for the first period, it automatically switches to the second period, then to
the third and fourth. Thus will continue with the setting of the 4 periods for
each day of the week (1 – 7).
- Note : The time can be set from 15 to 15 minutes and the temperature from half to half a degree. For example, you can set the time to 07:15 or 07:30 or 07:45 and the temperature to 22.0°C or 22.5°C or 23.0°C.
Note: Briefly press the PRG key to confirm a setting. Press the MENU key to exit.
Default settings
Period | 1 | 2 |
---|---|---|
Hour | Temp. | Hour |
12345
(Mon-Fri)
| 07:00| 22°C| 08:30| 19°C
6 (Sat)| 08:00| 22°C| 08:30| 22°C
7 (Sun)| 08:00| 22°C| 08:30| 22°C
Period| 3| 4
| Hour| Temp.| Hour| Temp.
12345
(Mon-Fri)
| 17:00| 22°C| 17:00| 19°C
6 (Sat)| 17:00| 22°C| 22:00| 19°C
7 (Sun)| 17:00| 22°C| 22:00| 19°C
Note: Press the ▲or ▼key to display the set temperature on the screen. Wait a few seconds, the screen will return to room temperature display mode.
Functions
Key lock function
If the Child protection function has been activated in the advanced settings
menu (see page 12), the thermostat keys will lock as soon as the screen
backlight turns off.
Press the MENU key for 5 seconds to temporarily unlock the keys.
Open window detection (OWD)
If the function has been activated from the advanced settings menu (see page
12), the thermostat will turn off the heating if the room temperature drops
suddenly (default setting 2°C in 15 minutes). This sudden drop in temperature
occurs when a window or door is opened while the boiler is operating. The OP
icon appears on the screen.
The device will return to its original operating mode after 30 minutes. The OP
icon disappears from the screen. By pressing any key, you will exit OWD mode.
Advanced settings
Switch off the thermostat by briefly pressing the key.
Press the MENU and ▲ keys simultaneously for about 6 seconds. 01 0.3°C will
appear on the screen. Use the ▲ and ▼ keys to change the settings and the MENU
key to move to the next setting.
Menu | Description | Range | Default |
---|---|---|---|
01 | Internal sensor temperature calibration | -8°C~8°C | 0°C |
02 | Setting the maximum temperature limit | 5°~35°C | 35°C |
03 | Set minimum temperature limit | 5°C~35°C | 5°C |
05 | Anti-freeze temperature | 5°C~15°C | 5°C |
--- | --- | --- | --- |
09 | Hysteresis | 0.1~6°C | 0.3°C |
10 | Screen display | 0: room temp. |
1: set temp.
| 0
11| Child protection| 0: keys unlocked 1: keys locked| 0
12| Open window detection| 1: On
0: Off
| 0
13| The time interval in which the sudden drop in temperature is detected|
2~30 min.| 15 min.
14| Degrees lost in the time interval set at menu 13| 2°C 3°C 4°C| 2°C
---|---|---|---
15| The time after which the device returns to its original mode of operation|
10~60 min| 30 min.
17| Reset| 0: No 1: Yes. Press for 5 seconds.| 0
| Software version| |
Connection diagram
The connection of the receiver unit to a 230V power supply and to a heating system must be performed only by qualified personnel and only after prior consultation of the technical documentation of the thermostat and the heating system. The receiver unit has a relay type control (NO Normal Open and NC Normal Closed) without potential (non-energized) which executes the closing of a control circuit with a maximum current of 10A and a maximum voltage of 250VAC/DC. Find examples of connections with certain models of the heating systems at the end of the manual.
Connections examples
Ariston CLAS EVO SYSTEM
Ferroli DivaCondens 24/28
Vaillant Ecotec Pure
Simplified EU declaration of conformity
SC ONLINESHOP SRL declares that PNI CT60 Wireless Thermostat is in accordance
with RED Directive 2014/53/EU. The full text of the EU Declaration of
Conformity is available at the following website:
https://www.mypni.eu/products/8001/download/certifications
PNI CT60 Wireless Thermostat User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>