BALDR B0340WST2H2R-V7 Touch Screen Wireless Weather Station User Manual
- June 6, 2024
- BALDR
Table of Contents
- BALDR B0340WST2H2R-V7 Touch Screen Wireless Weather Station
- PRODUCT OVERVIEW
- PACKAGING INCLUDES
- QUICK SET‐UP GUIDE
- Setting Order
- TEMPERATURE & HUMIDITY TREND ARROWS
- COMFORT LEVEL INDICATOR
- WEATHER FORECAST ICONS
- BACKLIGHT FUNCTION
- LOW BATTERY INDICATOR
- SPECIFICATIONS
- TROUBLESHOOTING GUIDE
- CARE AND MAINTENANCE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BALDR B0340WST2H2R-V7 Touch Screen Wireless Weather Station
PRODUCT OVERVIEW
WEATHER STATION(MAIN UNIT)
- Outdoor Sensor Channel Indicator
- Current Outdoor Temperature&Humidity
- “CH/▲”Button Switch channel, clear channel data, or value increase
- “RCC/SET” Button Search atomic time signal or enter into time setting
- “MEM/▼”Button Check or clear max/min records, or value decrease
- “ ”Button Check or enter into alarm setting
- Low Battery Indicator Remind to replace the new batteries
- Current Indoor Temperature and Humidity
- Temperature Trend Arrow UP/DOWN
- Weekday in 7 Languages
- Calendar Display Month/date or date/month optional
- Comfort Level Indicator
- Humidity Trend Arrow UP/DOWN
- Weather Forecast Icon
- Atomic Reception
- Backlight/Snooze Button
- Time (12/24 hours format optional)
- AM/PM
- Max/Min Records of Indoor and Outdoor Temperature and Humidity
- Hanging Hole
- Battery Compartment Cover
- Removable Stand
REMOTE SENSOR
- Signal Indicator Light
- Hanging Hole
- Battery Compartment
- Channel 1‐2‐3 Switch
BUTTONS INTRODUCTION
BUTTONS | FUNCTIONS |
---|
| 1. PRESS to switch channel from CH1, CH2, CH3, or cycle mode“ ”.
2. PRESS AND HOLD 3 seconds to clear channel data.
3. Value ▲ increase button.
| 1. PRESS to search WWVB atomic time signal automatically.
2. PRESS AND HOLD to set atomic time ON/OFF, time zone, time and calendar, language, ℃/℉.
3. SET button and set exit button.
| 1. PRESS to check 24 hours MAX/MIN indoor and outdoor temperature and humidity.
2. PRESS AND HOLD to clear the MAX/MIN records.
3. Value ▼ decrease button.
**| 1. PRESS** to view alarm time, activate/deactivate alarm (the alarm icon will display when activated).
2. PRESS AND HOLD to enter into alarm setting.
TOP BUTTON
| 1. BACKLIGHT: press to turn on the backlight (auto off after 20s).
2. SNOOZE when alarm rings, silence alarm for 5 minutes.
PACKAGING INCLUDES
Following contents are included in the packaging:
1 x Weather Station Main Unit (not included AAA batteries) 1 x Remote Sensor
(not included AA batteries)
1 x User Manual
QUICK SET‐UP GUIDE
NOTE: Prepare new and high-quality alkaline batteries. Do not mix old and new
batteries. Heavy duty or rechargeable batteries are not recommended.
POWER UP
-
Remove the battery door on the back of the display, insert 3 new AAA batteries in the back of the display console (please take note of the battery polarity before inserting the batteries).
Note: The display will beep once and all of the LCD segments will light up for few seconds to verify all segments are operating properly, then display indoor temperature and humidity immediately. -
Take out the metal stand inside the battery compartment and screw it into the hole at the main unit backside. Replace the battery door.
-
Remove the battery door of remote sensor, and set the channel of sensor to CH1, then insert 2 new AA batteries in the back of the sensor within 3 MINUTES.
Note:
- Make sure outside sensor and weather station main unit are at the same channel.
- Do not touch any buttons until the remote sensor reports in, otherwise the remote sensor searching will be terminated. When the remote sensor data has been received, all further settings can be performed.
- The display main unit will automatically receive remote sensor signal when sensor is powered up. The receiving status will last for max 3 minutes ( signal sensor will flash), if no signal received within 3 minutes, it will stop receiving, now you can press and hold the “CH/▲” Button 3 seconds to start receiving outside signal again.
WWVB RADIO CONTROLLED CLOCK (RCC)
After the remote sensor is powered up, it will start receiving the outdoor
sensor’s signal for 3 minutes, and then the sensor will begin radio controlled
clock (RCC) reception for 7 minutes.
- The antenna symbol ” “will flash while receiving signal, and will be solid “ ”once signal is received, and received time/month/date/weekday will display on the screen.
- The weather station will receive RCC signal at UTC 7:00, 8:00, 9:00, 10:00, and 11:00 each day. It starts receiving RCC signal at UTC 7:00 everyday, once signal is received at any above time, it will stop receiving signal that day.
- Manual receiving: press “RCC/SET” to enter or exit RCC signal receiving.
- Please be sure you have selected your time zone from the list in the SET menu. When the RCC signal is received, the weather station will set to the time zone selected. Default time zone is EST (Eastern Standard Time).
- During the RCC time reception period, no weather data will be transmitted to avoid interference.
RCC Symbol Display
- When receiving signal , RCC symbol ” ” will be flashing.
- When signal successfully received, LCD will display the complete RCC symbol “ ” and exit RCC receiving.
- If no signal is received, the RCC symbol will disappear.
MANUAL SETTINGS
NOTE: After RCC signal received, if there is no need for other settings,
you can skip the manual settings part. If no RCC signal received or you need
to set other settings, please follow the bellow steps to finish setting.
TIPS:
- Press and hold “RCC/SET” button to enter time set mode.
- Press “CH/▲”and“MEM/▼” buttons to adjust the values. Hold to adjust quickly.
- Press “RCC/SET” button to confirm and move to the next setting.
- Press the “Backlight/Snooze” button anytime to exit settings.
Setting Order
- Atomic ON/OFF
- Time Zone (Atomic ON)
- DST ON/OFF
- 12H/24H
- Hour
- Minutes
- Year
- Month & Date Display
- Month
- Date
- Language
- ℃(Celsius)/ °F(Fahrenheit)
Detailed Manual Setting Steps
- Press and hold “RCC/SET” button for 5 seconds to enter settings.
- Press “RCC/SET” to select ATOMIC ON/OFF. Press “CH/▲” or “MEM/▼” buttons to select ON or OFF. (Note: If ATOMIC OFF is selected, it will skip Time Zone setting and move to 12/24 Hour setting.)
- Press “RCC/SET” to select Time Zone. Press “CH/▲”or“MEM/▼” to select a time zone: AST, EST, CST, MST, PST, AKST, HST. (Default setting: ‐5 EST).
- Press “RCC/SET” to select DST ON/OFF. Default setting: ON. Press “CH/▲” or “MEM/▼” to select DST ON if you do observe Daylight Saving Time.
- Press “RCC/SET” to select 12/24‐hour format. Press “CH/▲”or“MEM/▼” to select 12‐hour format or 24‐hour format.
- Press “RCC/SET” to select the Hours. Press “CH/▲”or“MEM/▼” to adjust the hour.
- Press “RCC/SET” to select the Minutes. Press “CH/▲”or“MEM/▼”to adjust the minutes.
- Press “RCC/SET” to select the Year (year range: 2000‐2099). Press “CH/▲” or “MEM/▼” to adjust the year.
- Press “RCC/SET” to select Month & Date display format. Press “CH/▲”or “MEM/▼” to select Month/Date or Date/Month format.
- Press “RCC/SET” to select the Month. Press “CH/▲”or“MEM/▼”to adjust the month.
- Press “RCC/SET” to select the Date. Press “CH/▲” or “MEM/▼” to adjust the date.
- Press “RCC/SET” to select Weekday Language. Press “CH/▲”or “MEM/▼” to adjust the language. Optional language: ENG(English), DUT(Dutch), DAN(Danish), SPA(Spanish), ITA(Italian), GER(German), FRE(French).
- Press “RCC/SET” to select ℃ (Celsius)/ °F(Fahrenheit). Press “CH/▲”or “MEM/▼” to select Celsius or Fahrenheit.
- Press “RCC/SET” to confirm and exit.
Hours from GMT | Time Zone | Description |
---|---|---|
‐4 | AST | Atlantic Standard Time |
‐5 | EST | Eastern Standard Time |
‐6 | CST | Central Standard Time |
‐7 | MST | Mountain Standard Time |
‐8 | PST | Pacific Standard Time |
‐9 | AKST | Alaska Standard Time |
‐10 | HST | Hawaii Standard Time |
DST symbol display:
- Select “DST ALWAYS” , which means the DST function is always on all year-round.
- Select “DST ”, which means the DST function will be on during daylight saving time.
- Select “DST OFF”, which means the DST function is off.
NOTE :
- When Atomic OFF is selected, will move directly to 12/24 hour time setting.
- Weekday will set automatically as Year, Month and Date are set.
- When relevant language is selected, the rest of the instructions will be in that language.
- During setting, if no operation for 20 seconds, it will automatically save and exit setting.
REMOTE SENSOR INSTALLATION
When the remote sensor is first used, please put the weather station main unit
and the remote sensor together at the same position for 30 minutes to
establish a strong connection.
- To insure optimum reception, mount the remote sensor vertically, do not lay down on a flat surface. Please mount the remote sensor at a height of 2‐2.5m/6.56ft off the ground.
- Direct sunlight and radiant heat sources will result in inaccurate temperature readings, so a north‐side, shaded location is best.
- Avoid direct rain, it is best to mount in a well‐protected area, such as under the eaves.
- It is recommended to mount the remote sensor at least 50 feet away from plant life and large bodies of water, because these factors may result in inaccurate humidity readings.
- Provide good airflow around the remote sensor to reflect the changes of environment.
- Wireless signals are impacted by distance, interference (wireless phones, wireless routers, TVs, microwaves, computer monitors, etc.), and transmission barriers such as thick wall, solid metal. Make sure there’s no thick wall or other strong interference between the weather station main unit and sensor, place them at least 3ft/0.9m away from interference.
- You can mount the sensor in multiple ways: place on a stable surface, mount to the wall using a nail, or lift with a rope. In whatever way, make sure at least one side of the sensor air vent (back or bottom) is not blocked.
ALARM TIME SETTING
- Press and hold “ ” button to enter into alarm time setting.
- Press “CH/▲”or“MEM/▼” button to set alarm hour, and press “ ” button to confirm and enter minutes setting.
- Press “CH/▲”or“MEM/▼” button to adjust the alarm minutes, and press “ ”buttontoconfirmandexitalarmsetting.
- When in time display mode, press “ ” button once to check alarm time.
- Press “ ” button twice to turn ON/OFF alarm. Alarm symbol “ ”will appear or disappear on the screen.
- To return to normal mode, press the TOP BUTTON.Ifnooperation for20 seconds, it will automatically save and exit.
SNOOZE FUNCTION
- When alarm rings, the ascending “Bibi” alarm sound will last for 2 minutes if no operation.
- When alarm rings, press the TOP BUTTON to activate snooze function ( symbol will flash on screen). After 5 minutes, the alarm will ring again.
- When alarm rings, press any other button except TOP BUTTON to stop the alarm rings. And the alarm will restart next day.
MAX/MIN TEMPERATURE & HUMIDITY RECORDS
Note: All Max and Min records will update every 24 hours at 12:00
(midnight).
- While in normal mode, press “MEM/▼” button to enter the maximum mode, and the MAX icon and maximum records will be displayed. Press “MEM/▼” button again to enter the minimum mode, the MIN icon and minimum records will be displayed. Press “MEM/▼” button again to return the normal mode.
- The max and min records will display for 3 seconds, then automatically exit.
- Clear max/min records: press “MEM/▼” once (Maximum Mode), then press and hold “MEM/▼” to clear Max record. Press “MEM/▼”again (Minimum Mode), then press and hold “MEM/▼”toclear Minrecord.
TEMPERATURE & HUMIDITY TREND ARROWS
The temperature and humidity trend arrows update every 15 minutes, indicating whether the temperature or humidity is rising, falling or remaining the same.
| Arrows
Indicator
|
Humidity
|
Temperature
---|---|---|---
Up Arrow
| Humidity has risen 3% RH in the past hour.| Temperature has risen 1.8°F in the past hour.
Down Arrow
| Humidity has fallen 3% RH in the past hour.| Temperature has fallen 1.8°F in the past hour.
No Arrows
| Humidity has no change in the past
hour.
| Temperature has no change in the past
hour.
COMFORT LEVEL INDICATOR
Indoor comfort level indicator keeps you informed the comfort level in your home, and when to dehumidify or humidify.
DRY: Humidity < 30%
COMFORT: 30% < Humidity < 60%, 68°F < Temperature < 79°F
WET : Humidity > 60%
WEATHER FORECAST ICONS
There are 5 kinds of weather icons. The weather icon display is based on the
hourly calculation of indoor and outdoor temperature, humidity and barometric
data. It predicts weather condition of the next 12 hours, and is about 70‐75%
correct.
Note : When powered on or restored, the weather icon will be default
“Sunny To Cloudy”.
BACKLIGHT FUNCTION
When powered on, press the top button to turn on the backlight, and the backlight will last 20 seconds to save batteries.
LOW BATTERY INDICATOR
- When Battery Indicator shows next to the Outdoor Temperature, replace batteries in your Outdoor Sensor.
- When Battery Indicator shows next to the Indoor Temperature, replace batteries in your Weather Station.
SPECIFICATIONS
TECHNICAL SPECIFICATION
- Indoor Temperature Range: 14 °F~ 122 °F(‐10℃~50.0℃)
- Outdoor Temperature Range: ‐40 °F~140 °F(‐40℃~60℃)
- Humidity Range: 1% to 99% RH
- Transmission Range: 328 ft (100 meters), 433MHZ (open air)
- Power Requirements: Weather Station: 3 x AAA Alkaline batteries (not included), Remote Sensor: 2 x AA Alkaline batteries (not included)
MEASUREMENT SPECIFICATIONS
The following table provides the specifications of the measurement parameters.
Measurement | Range | Accuracy | Resolution |
---|
Indoor
Temperature
|
14 °F~ 122 °F
| ±2 °F (between 32~122°F, if out of
this range: ±3.6 °F)
|
0.1 °F
Outdoor
Temperature
|
‐40 °F~140 °F
| ±2 °F (between 32~122°F, if out of
this range: ±3.6 °F)
|
0.1 °F
Indoor Humidity
|
1% to 99%
| ± 5% (humidity between 30‐80%, if
out of this range: ±7%)
|
1%
Outdoor
Humidity
|
1% to 99%
| ± 5% (humidity between 30‐80%, if
out of this range: ±7%)
|
1%
TROUBLESHOOTING GUIDE
Problem | Possible Solution |
---|---|
Outdoor sensor signal is lost or showing dashes (‐ ‐) on the display |
1. Resync the unit. Press and hold the “CH/▲” button for 5‐6 seconds to resynchronize. The sensor search icon will flash while searching and be solid when sensor signal is received. Please wait several minutes for the sensor to report in or the search icon to turn off.
2. If you regain connection while the sensor is mounted, great. If the the synchronization fails, bring the sensor within 10 feet of the weather station and try the bellow methods:
1) Remove the batteries of Sensor, wait 10 seconds. Then press and hold the “CH/▲” button for 5‐6 seconds, then reinsert the batteries of sensor. (Please make sure the sensor and display console have the same channel.)
2) Factory Restart: Firstly remove all the batteries of sensor and display console. Then set the channel of Sensor to “CH1”. Reinsert the batteries of display console and press “CH/▲” button to choose “CH1”. Then reinsert the batteries of sensor, allow the whole set device to sit together for 30 minutes to establish a strong connection.
3. Checked the remote sensor is powered up.
4. The maximum transmission range is
| 328ft/100m, move the sensor closer to the display console.
5. Make sure both display console and sensor are placed at least 3ft/0.9m away from electronics that may interfere with the wireless communication, such as computers, TVs, microwaves, other wireless transmitters or receivers, etc.
6. Make sure the sensor is not transmitting through solid metal or thick walls. Radio Frequency (RF) Sensors cannot transmit through metal barriers or thick walls. (Please refer REMOTE SENSOR INSTALLATION)
---|---
Outdoor temperature and humidity always keep cycling/how to exit the CYCLE
mode| “ ”. cycle symbol means that weather station enter channels cycle mode,
it will display the values of 3 channels in order every 10 seconds.
Press the “CH/▲” button to cancel cycle symbol.
Temperature reads too high in the daytime
| Make sure both the display console and sensor are placed out of direct sunlight and away from any heat sources or vents.
Indoor and outdoor temperature and humidity do not agree
| Allow up to two hours for the sensor to stabilize due to signal filtering. The indoor and outdoor temperature sensor should agree within 4℉. And indoor and outdoor humidity sensor should agree
within 10%.
Inaccurate weather forecast
| The weather forecast is an estimate or generalization of weather changes in
the next 12 to 24 hours, with an accuracy rate of about 70‐75%. It is simply
a tool for projecting weather conditions and is never to be relied upon as an
accurate method to predict weather.
---|---
Display console contrast
is weak
| Battery is low, replace a new set of batteries.
Incorrect weekday display| Press and hold “RCC/SET” button to select the
correct Year (year range: 2000‐2099).
Indoor/Outdoor temperature shows “HH.H/LL.L” on display
| 1. If indoor temperature is lower than 14 °F/‐10℃, the reading will be “LL.L”. If higher than 122 °F/50.0℃, the reading will be “HH.H”.
2. If outdoor temperature is lower than
‐40 °F/‐40℃, the reading will be “LL.L”. If higher than 140 °F/60℃, the reading will be “HH.H”.
If your BALDR weather station still can’t be worked well after trying the above troubleshooting steps, please contact the seller on your order page or visit htt ps://w ww .bald r .com or email us by baldrservice@baldr.com for
help.
CARE AND MAINTENANCE
- Do not mix old and new batteries.
- Do not mix Alkaline, Standard, Lithium, or Rechargeable batteries with this product.
- Remove the batteries from the device if not used for a long time.
- Ensure the batteries are installed with correct polarity (+ and ‐).
- Do not clean any part of the product with benzene, thinner or other solvent chemicals. Use a soft cloth to clean it when necessary.
- Never immerse the product in water. This can cause electrical shock and damage the product.
- Do not expose the product to extreme force, shock or temperature or humidity fluctuations.
- Do not tamper with internal components.
WARRANTY
Dear customer,
Thank you for choosing BALDR. We provide 1‐year limited warranty on this
product from the date of purchase. This product has undergone thorough quality
inspection at the factory to ensure that the product is in good condition. We
will remedy all defects in workmanship or materials within the warranty
period.
In order for the warranty to be granted, all warranty claims must be
accompanied by proof of purchase from an authorized distribution partner.
Damages due to improper installation or use, unauthorized removal, modify,
repair are not covered by the warranty.
If you have any problems with this product or during use, please do not
hesitate to contact us, we will try our best to solve it and offer you
satisfactory service including replacement or refund.
For Full Warranty Details, contact
baldrservice@baldr.com.
Email:baldrservice@baldr.com
US TEL:1‐833‐381‐5659 (Support Hours: Monday‐Friday, 9 am‐5 pm PST)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>