MITSUBISHI ELECTRIC FR-F800 Series Inverters User Guide
- June 3, 2024
- Mitsubishi Electric
Table of Contents
FR-F800 Series Inverters
User Guide
FR-F800 Series Inverte
Pocket Reference Guide
Cross-Over Chart 208-230V (Assumes SLD Rating)
HP | FR-F720 | FR-F820 |
---|---|---|
1 | FR-F720-00046-NA | FR-F820-00046-E3N6 |
2 | FR-F720-00077-NA | FR-F820-00077-E3N6 |
3 | FR-F720-00105-NA | FR-F820-00105-E3N6 |
5 | FR-F720-00167-NA | FR-F820-00167-E3N6 |
7.5 | FR-F720-00250-NA | FR-F820-00250-E3N6 |
10 | FR-F720-00340-NA | FR-F820-00340-E3N6 |
15 | FR-F720-00490-NA | FR-F820-00490-E3N6 |
20 | FR-F720-00630-NA | FR-F820-00630-E3N6 |
25 | FR-F720-00770-NA | FR-F820-00770-E3N6 |
30 | FR-F720-00930-NA | FR-F820-00930-E3N6 |
40 | FR-F720-01250-NA | FR-F820-01250-E3N6 |
50 | FR-F720-01540-NA | FR-F820-01540-E3N6 |
60 | FR-F720-01870-NA | FR-F820-01870-E3N6 |
75 | FR-F720-02330-NA | FR-F820-02330-E3N6 |
100 | FR-F720-03160-NA | FR-F820-03160-E360 +FR-HEL-90K |
125 | FR-F720-03800-NA | FR-F820-03800-E3U6 +FR-HEL-110K |
150 | FR-F720-04750-NA | FR-F820-04750-E3U6 +FR-HEL-110K |
This chart shows the closest equivalent in performance between FR-F700 and
FR-F800 drives.
FR-F820 Selection Chart
Model Number| AMPS For Duty| Horsepower For Duty (NEC)|
**Frame Size| ****Weight (lbs)
---|---|---|---|---
SLD| LD| SLD| LD
FR-F820-00046 – E3N6| 4.6| 4.2| 1| 1| A| 6
FR-F820-00077-E3N6| 7.7| 7| 2| 2| B| 6
FR-F820-00105-E3N6| 10.5| 9.6| 3| 3| **
C
| 9
FR-F820-00167-E3N6| 16.7| 15.2| 5| 5| 9
FR-F820-00250-E3N6| 25| 23| 7.5| 7.5| 9
FR-F820-00340-E3N6| 34| 31| 10| 10| D| 17
FR-F820-00490-E3N6| 49| 45| 20| 15| 17
FR-F820-00630-E3N6| 63| 58| 20| 20| E| 20
FR-F820-00770-E3N6| 77| 70.5| 25| 25| ****
F
| 37
FR-F820-00930-E3N6| 93| 85| 30| 30| 37
FR-F820-01250-E3N6| 125| 114| 40| 40| 37
FR-F820-01540-E360| 154| 140| 60| 50| G| 48
FR-F820-01870-E360| 187| 170| 60| 60| H| 92
FR-F820-02330-E360| 233| 212| 75| 75| 92
FR-F820-03160-E360| 316| 288| 125| 100| K| 119
FR-F820-03800-E3U6| 380| 346| 150| 125| L| 163
FR-F820-04750-E3U6| 475| 432| 150| 150| 163
Important Note: Drives in shaded area MUST be used together with FR-HEL
DC Link Choke (sold separately). Weights do not include separate DC Link
chokes.
FR-HEL DC Link Chokes (sold separately)
Drives in shaded area above MUST be used together with a DC Link Choke
Model Number| LD|
SLD
---|---|---
FR-F820-03160-E360| FR-HEL-75K| FR-HEL-90K
FR-F820-03800-E3U6| FR-HEL-90K| FR-HEL-110K
FR-F820-04750-E3U6| FR-HEL-110K| FR-HEL-110K
Key to Duty Codes
| Overload Rating
---|---
60s| 3s| Ambient Temp.
SLD| 110%| 120%| 40°C
LD| 120%| 150%| 50°C
Cross-Over Chart 460-480V (Assumes SLD Rating)
HP| FR-F740|
FR-F840
---|---|---
1| FR-F740-00023-NA| FR-F840-00023-E3N6
2| FR-F740-00038-NA| FR-F840-00038-E3N6
3| FR-F740-00052-NA| FR-F840-00052-E3N6
5| FR-F740-00083-NA| FR-F840-00083-E3N6
7.5| FR-F740-00126-NA| FR-F840-00126-E3N6
10| FR-F740-00170-NA| FR-F840-00170-E3N6
15| FR-F740-00250-NA| FR-F840-00250-E3N6
20| FR-F740-00310-NA| FR-F840-00310-E3N6
25| FR-F740-00380-NA| FR-F840-00380-E3N6
30| FR-F740-00470-NA| FR-F840-00470-E3N6
40| FR-F740-00620-NA| FR-F840-00620-E3N6
50| FR-F740-00770-NA| FR-F840-00770-E3N6
60| FR-F740-00830-NA| FR-F840-00930-E360
75| FR-F740-01160-NA| FR-F840-01160-E360
100| FR-F740-01800-NA| FR-F840-01800-E360 +FR-HEL-H90K
150| FR-F740-02160-NA| FR-F840-02160-E3U6 +FR-HEL-H110K
200| FR-F740-02600-NA| FR-F840-02600-E3U6 +FR-HEL-H132K
250| FR-F740-03250-NA| FR-F840-03250-E3U6 +FR-HEL-H160K
300| FR-F740-03610-NA| FR-F840-03610-E3U6 +FR-HEL-H185K
350| FR-F740-04320-NA| FR-F840-04320-E3U6 +FR-HEL-H220K
400| FR-F740-04810-NA| FR-F840-04810-E3U6 +FR-HEL-H250K
450| FR-F740-05470-NA| FR-F840-05470-E3U6 +FR-HEL-H280K
500| FR-F740-06100-NA| FR-F840-06100-E3U6 +FR-HEL-H315K
550| FR-F740-06830-NA| FR-F840-06830-E3U6 +FR-HEL-H355K
650| FR-F740-07700-NA| FR-F842-07700-E3U6 +FR-CC2-H400K-60
700| FR-F740-08660-NA| FR-F842-08660-E3U6 + FR-CC2-H450K-60
800| FR-F740-09620-NA| FR-F842-09620-E3U6 +FR-CC2-H500K-60
900| FR-F740-10940-NA| FR-F842-10940-E3U6 +FR-CC2-H560K-60
1000| FR-F740-12120-NA| FR-F842-12120-E3U6 +FR-CC2-H630K-60
This chart shows the closest equivalent in performance between FR-F700 and FR-F800 drives.
FR-F840 Selection Chart
**Model Number| AMPS For Duty| Horsepower For Duty (NEC)|
****Frame Size| ****Weight (lbs)*
---|---|---|---|---
SLD| LD| SLD| LD
FR-F840-00023-E3N6| 2.3| 2.1| 1| 1| C| 8
FR-F840-00038-E3N6| 3.8| 3| 2| 2| 8
FR-F840-00052-E3N6| 5.2| 4.8| 3| 3| 8
FR-F840-00083-E3N6| 8.3| 7.6| 5| 5| 9
FR-F840-00126-E3N6| 12.6| 11.5| 7.5| 7.5| 9
FR-F840-00170-E3N6| 17| 16| 10| 10| D| 17
FR-F840-00250-E3N6| 25| 23| 15| 15| 17
FR-F840-00310-E3N6| 31| 29| 20| 20| E| 20
FR-F840-00380-E3N6| 38| 35| 25| 25| 20
FR-F840-00470-E3N6| 47| 43| 30| 30| F| 37
FR-F840-00620-E3N6| 62| 57| 40| 40| 37
FR-F840-00770-E360| 77| 70| 60| 50| G| 51
FR-F840-00930-E360| 93| 85| 60| 60| ** H| 90
FR-F840-01160-E360| 116| 106| 75| 75| 90
FR-F840-01800-E360| 180| 144| 150| 100| 95
FR-F840-02160-E3U6| 216| 180| 150| 150| J| 114
FR-F840-02600-E3U6| 260| 216| 200| 150| 121
FR-F840-03250-E3U6| 325| 260| 250| 200| L| 156
FR-F840-03610-E3U6| 361| 325| 300| 250| 172
FR-F840-04320-E3U6| 432| 361| 350| 300| M| 257
FR-F840-04810-E3U6| 481| 432| 400| 350| 257
FR-F840-05470-E3U6| 547| 481| 450| 400| ****
N
| 365
FR-F840-06100-E3U6| 610| 547| 500| 450| 365
FR-F840-06830-E3U6| 683| 610| 550| 500| 365
FR-F842-07700-E3U6 + FR-CC2-H355K-60| –| 683| –| 550| P+R| 827
FR-F842-07700-E3U6 + FR-CC2-H400K-60| 770| –| 650| –| ****
P+S
| 979
FR-F842-08660-E3U6 + FR-CC2-H400K-60| –| 770| –| 650| 979
FR-F842-08660-E3U6 + FR-CC2-H450K-60| 866| –| 700| –| 986
FR-F842-09620-E3U6 + FR-CC2-H450K-60| –| 866| –| 700| Q+S| 1162
FR-F842-09620-E3U6 + FR-CC2-H500K-60| 962| –| 800| –| 1168
FR-F842-10940-E3U6 + FR-CC2-H500K-60| –| 962| –| 800| 1168
FR-F842-10940-E3U6 + FR-CC2-H560K-60| 1094| –| 900| –| 1168
FR-F842-12120-E3U6 + FR-CC2-H560K-60| –| 1094| –| 900| 1168
FR-F842-12120-E3U6 + FR-CC2-H630K-60| 1212| –| 1000| –| 1168
Weights of the drive and the CC2 modules are COMBINED
Important Note: Drives in shaded area MUST be used together with FR-HEL-H DC
Link Choke (sold separately). Weights do not include separate DC Link chokes.
FR-HEL-H DC Link Chokes (sold separately)
Drives shown in shaded area of the FR-F840 Selection Chart MUST be used
together with a DC Link Choke
Model Number
| LD|
SLD
---|---|---
FR-F840-01800-E360| FR-HEL-H75K| FR-HEL-H90K
FR-F840-02160-E3U6| FR-HEL-H90K| FR-HEL-H110K
FR-F840-02600-E3U6| FR-HEL-H110K| FR-HEL-H132K
FR-F840-03250-E3U6| FR-HEL-H132K| FR-HEL-H160K
FR-F840-03610-E3U6| FR-HEL-H160K| FR-HEL-H185K
FR-F840-04320-E3U6| FR-HEL-H185K| FR-HEL-H220K
FR-F840-04810-E3U6| FR-HEL-H220K| FR-HEL-H250K
FR-F840-05470-E3U6| FR-HEL-H250K| FR-HEL-H280K
FR-F840-06100-E3U6| FR-HEL-H280K| FR-HEL-H315K
FR-F840-06830-E3U6| FR-HEL-H315K| FR-HEL-H355K
FR-F860 Ratings
**Model Number (*3)| AMPS for Duty| Horsepower for Duty
(NEC)| ****Frame Size| ****Weight (lbs)
---|---|---|---|---
SLD| LD| SLD| LD
FR-F860-00027-E3N6| 2.7| 2.5| 2| 1.5| C| 11.7
FR-F860-00061-E3N6| 6.1| 5.6| 5| 3| C| 12.8
FR-F860-00090-E3N6| 9| 8.2| 7.5| 5| C| 12.8
FR-F860-00170-E3N6| 17| 16| 15| 10| D| 15.4
FR-F860-00320-E3N6| 32| 27| 30| 25| E| 19.8
FR-F860-00450-E3N6| 45| 41| 40| 40| F| 37.4
FR-F860-00680-E360| 68| 62| 60| 60| H| 79.2
FR-F860-01080-E360 (1)| 108| 99| 100| 100| H| 90.2
FR-F860-01440-E360 (1)| 144| 131| 150| 125| J| 114
FR-F860-01670-E360 (1)| 167| 152| 150| 150| J| 114
FR-F860-02430-E360 (1)| 243| 221| 250| 200| J| 121
FR-F860-02890-E360 (1)| 289| 255| 300| 250| M| 246
FR-F860-03360-E360 (1)| 336| 304| 350| 300| M| 253
FR-F860-04420-E360 (1)| 442| 402| 450| 400| N| 337
FR-F862-05450-E360+ FR-CC2-C355K-60 (2)| 545| 496| 550| 500| P+R| 810
FR-F862-06470-E360+ FR-CC2-C400K-60 (2)| 647| 589| 650| 600| Q+S| 920
FR-F862-08500-E360+ FR-CC2-C560K-60 (2)**| 850| 773| 850| 750| Q+S| 1126
Notes:
- These drives MUST be used with a DC Link Choke (sold separately).
- FR-F862 Drives are inverter stage only; use together with FR-CC2-C rectifier Maximum Input and Output Current of FR-CC2 modules is the value shown. COMBINED weight shown.
- The FR-F860 does not include a built-in parameter The FR-DU08 or FR-LU08 is sold separately.
600V FR-HEL-C DC Link Chokes (sold separately)
Model Number| SLD|
LD
---|---|---
FR-F860-01080-E360| FR-HEL-C75K| FR-HEL-C75K
FR-F860-01440-E360| FR-HEL-C90K| FR-HEL-C90K
FR-F860-01670-E360| FR-HEL-C110K| FR-HEL-C110K
FR-F860-02430-E360| FR-HEL-C185K| FR-HEL-C132K
FR-F860-02890-E360| FR-HEL-C220K| FR-HEL-C185K
FR-F860-03360-E360| FR-HEL-C280K| FR-HEL-C220K
FR-F860-04420-E360| FR-HEL-C280K| FR-HEL-C280K
Frame Dimensions 200V, 400V, 600V Drives
FR-F800-E Model Number| Frame Size| Height| Width|
Depth
---|---|---|---|---
Dimensions Inches (mm)
**FR-F820-00046 (N6)| ** A| 12.2 (310)
10.24 (260)
w/o conduit box| 4.33 (110)| 4.41 (112)
**FR-F820-00077 (N6)| ** B| 12.2 (310)
10.24 (260)
w/o conduit box| 4.33 (110)| 5.00 (127)
FR-F820-00105, 00167, 00250 (N6) FR-F840-00023, 00038, 00052,
00083, 00126 (N6)
FR-F860-00027, 00061, 00090 (N6)| C| 12.52 (318)
10.24 (260)
w/o conduit box| 5.91 (150)| ** 5.51 (140)
FR-F820-00340, 00490 (N6)
FR-F840-00170, 00250 (N6)
FR-F860-00170 (N6)| ** D| 12.76 (324)
10.24 (260)
w/o conduit box| 8.66 (220)|
6.69 (170)
FR-F820-00630 (N6)
FR-F840-00310, 00380 (N6) FR-F860-00320 (N6)| E| “14.29
(363)
11.81 (300)
w/o conduit box| 8.66 (220)| ** 7.48 (190)
FR-F820-00770, 00930, 01250 (N6)
FR-F840-00470, 00620 (N6) FR-F860-00450 (N6)| ** F| 20.37
(517)
15.75 (400)
w/o conduit box| 9.84 (250)| 7.48 (190)
FR-F820-01540 FR-F840-00770| G| 21.65 (550)| 12.80 (325)| 7.68 (195)
FR-F820-01870, 02330
FR-F840-00930, 01160, 01800
FR-F860-00680, 01080| H| 21.65 (550)| 17.13 (435)|
9.84 (250)
FR-F840-02160, 02600
FR-F860-01440, 01670, 02430| J| 24.41 (620)| 18.31 (465)| 11.81 (300)
FR-F820-03160| K| 27.56 (700)| 18.31 (465)| 9.84 (250)
FR-F820-03800, 04750
FR-F840-03250, 03610| L| 29.13 (740)| 18.31 (465)| 14.17 (360)
FR-F840-04320, 04810
FR-F860-02890, 03360| M| 39.76 (1010)| 19.61 (498)| 14.96 (380)
FR-F840-05470, 06100, 06830 FR-F860-04420| N| 39.76 (1010)| 26.77
(680)| 14.96 (380)
FR-F842-07700, 08660 FR-F862-05450| P| 52.36 (1330)| 21.26
(540)| 17.32 (440)
FR-F842-09620, 10940, 12120
FR-F862-06470, 08500| Q| 62.20 (1580)| 26.77 (680)| 17.32 (440)
FR-CC2 Model Number| Frame Size| Height| Width| Depth
Dimensions Inches (mm)
FR-CC2-H315K, H355K, C355K| R| 52.36 (1330)| 23.62 (600)| 17.32 (440)
FR-CC2-H400K, H450H, H500K H560K, H630K, C400K, C560K| S| 62.20 (1580)|
23.62 (600)| 17.32 (440)
Note: Code (N6) is for UL type 1 conduit box.
Dimensions of REQUIRED DC Link Chokes (sold separately)
Model Number | Height | Width | Depth | Weight (lbs) |
---|
Dimensions inches (mm)
FR-HEL-75K| 13.4 (340)| 5.9 (150)| 7.9 (200)| 37
FR-HEL-90K| 13.4 (340)| 5.9 (150)| 7.9 (200)| 42
FR-HEL-110K| 15.8 (400)| 6.9 (175)| 7.9 (200)| 44
FR-HEL-H75K| 12.6 (320)| 5.9 (140)| 7.3 (185)| 35
FR-HEL-H90K| 13.4 (340)| 5.9 (150)| 7.5 (190)| 44
FR-HEL-H110K| 13.4 (340)| 5.9 (150)| 7.7 (195)| 48
FR-HEL-H132K| 15.9 (405)| 6.9 (175)| 7.9 (200)| 57
FR-HEL-H160K| 15.9 (405)| 6.9 (175)| 8.1 (205)| 62
FR-HEL-H185K| 15.9 (405)| 6.9 (175)| 9.4 (240)| 64
FR-HEL-H220K| 15.9 (405)| 6.9 (175)| 9.4 (240)| 66
FR-HEL-H250K| 17.3 (440)| 7.5 (190)| 9.8 (250)| 77
FR-HEL-H280K| 17.3 (440)| 7.5 (190)| 10.0 (255)| 84
FR-HEL-H315K| 19.49 (495)| 8.27 (210)| 9.84 (250)| 92
FR-HEL-H355K| 19.49 (495)| 8.27 (210)| 9.84 (250)| 101
FR-HEL-C75K| 12.6 (320)| 5.5 (140)| 7.3 (185)| 35
FR-HEL-C90K| 13.3 (340)| 5.9 (150)| 9.4 (240)| 44
FR-HEL-C110K| 13.3 (340)| 5.9 (150)| 9.4 (240)| 51
FR-HEL-C132K| 15.9 (405)| 6.9 (175)| 7.7 (195)| 53
FR-HEL-C185K| 15.9 (405)| 6.9 (175)| 9.4 (240)| 70
FR-HEL-C220K| 15.9 (405)| 6.9 (175)| 9.4 (240)| 73
FR-HEL-C280K| 17.3 (440)| 7.5 (190)| 9.8 (250)| 88
Peripheral Equipment Selection (Assumes LD Rating)
Model Number | Contactor | Circuit Breaker |
---|---|---|
No DCL | With DCL | No DCL |
200 Volt
FR-F820-00046-E3N6| S-T10| S-T10| NF50-SVFU3P10A| NF50-SVFU3P10A
FR-F820-00077-E3N6| S-T10| S-T10| NF50-SVFU3P15A| NF50-SVFU3P15A
FR-F820-00105-E3N6| S-T10| S-T10| NF50-SVFU3P20A| NF50-SVFU3P15A
FR-F820-00167-E3N6| S-T10| S-T10| NF50-SVFU3P30A| NF50-SVFU3P30A
FR-F820-00250-E3N6| S-T20, S-T21| S-T10| NF50-SVFU3P50A| NF50-SVFU3P40A
FR-F820-00340-E3N6| S-T25| S-T20, S-T21| NF125-SVU3P60A| NF50-SVFU3P50A
FR-F820-00490-E3N6| S-T25| S-T25| NF125-SVU3P75A| NF125-SVU3P75A
FR-F820-00630-E3N6| S-N35| S-N35| NF125-SVU3P125A| NF125-SVU3P100A
FR-F820-00770-E3N6| S-N50| S-N50| NF250-SVU3P150A| NF125-SVU3P125A
FR-F820-00930-E3N6| S-N65| S-N50| NF250-SVU3P175A| NF250-SVU3P150A
FR-F820-01250-E3N6| S-N80| S-N65| NF250-SVU3P225A| NF250-SVU3P175A
FR-F820-01540-E360| S-N95| S-N80| NF250-SVU3P250A| NF250-SVU3P225A
FR-F820-01870-E360| S-N150| S-N125| NF4SWU3300BB| NF4SWU3300BB
FR-F820-02330-E360| S-N180| S-N150| NF4SWU3400BB| NF4SWU3350BB
FR-F820-03160-E360| S-N220| S-N180| –| NF4SWU3400BB
FR-F820-03800-E3U6| –| S-N300| –| NF4SWU3400BB
FR-F820-04750-E3U6| –| S-N300| –| NF6SWU3500BB
400 Volt
FR-F840-00023-E3N6| S-T10| S-T10| NF100-HRU3P5A| NF100-HRU3P5A
FR-F840-00038-E3N6| S-T10| S-T10| NF100-HRU3P10A| NF100-HRU3P10A
FR-F840-00052-E3N6| S-T10| S-T10| NF100-HRU3P10A| NF100-HRU3P10A
FR-F840-00083-E3N6| S-T10| S-T10| NF125-SVU3P20A| NF125-SVU3P15A
FR-F840-00126-E3N6| S-T10| S-T10| NF125-SVU3P30A| NF125-SVU3P20A
FR-F840-00170-E3N6| S-T20, S-T21| S-T12| NF125-SVU3P30A| NF125-SVU3P30A
FR-F840-00250-E3N6| S-T20, S-T21| S-T20, S-T21| NF125-SVU3P50A|
NF125-SVU3P40A
FR-F840-00310-E3N6| S-T20, S-T21| S-T20, S-T21| NF125-SVU3P60A|
NF125-SVU3P50A
FR-F840-00380-E3N6| S-T25| S-T20, S-T21| NF125-SVU3P75A| NF125-SVU3P60A
FR-F840-00470-E3N6| S-T25| S-T25| NF125-SVU3P100A| NF125-SVU3P75A
FR-F840-00620-E3N6| S-N35| S-T25| NF125-SVU3P125A| NF125-SVU3P100A
FR-F840-00770-E360| S-N50| S-N50| NF250-SVU3P150A| NF125-SVU3P125A
FR-F840-00930-E360| S-N65| S-N65| NF250-SVU3P175A| NF250-SVU3P150A
FR-F840-01160-E360| S-N80| S-N80| NF250-SVU3P200A| NF250-SVU3P175A
FR-F840-01800-E360| S-N80| S-N95| –| NF250-SVU3P225A
Model Number| Contactor| Circuit Breaker
---|---|---
No DCL| With DCL| No DCL| With DCL
FR-F840-02160-E3U6| –| S-N150| –| NF250-SVU3P225A
FR-F840-02600-E3U6| –| S-N180| –| NF250-SVU3P225A
FR-F840-03250-E3U6| –| S-N220| –| NF4SWU3400BB
FR-F840-03610-E3U6| –| S-N300| –| NF4SWU3400BB
FR-F840-04320-E3U6| –| S-N300| –| NF4SWU3400BB
FR-F840-04810-E3U6| –| S-N300| –| NF6SWU3500BB
FR-F840-05470-E3U6| –| S-N400| –| NF6SWU3600BB
FR-F840-06100-E3U6| –| S-N600| –| NF6SWU3600BB
FR-F840-06830-E3U6| –| S-N600| –| 700A Product
FR-F842-07700-E3U6| –| S-N600| –| 700A Product
+ FR-CC2-H315K-60
FR-F842-08660-E3U6| –| S-N600| –| 700A Product
+ FR-CC2-H315K-60
FR-F842-07700-E3U6| –| S-N600| –| 800A Product
+ FR-CC2-H355K-60
FR-F842-08660-E3U6| –| S-N600| –| 800A Product
+ FR-CC2-H355K-60
FR-F842-09620-E3U6| –| S-N600| –| 800A Product
+ FR-CC2-H355K-60
FR-F842-07700-E3U6| –| S-N800| –| 900A Product
+ FR-CC2-H400K-60
FR-F842-08660-E3U6| –| S-N800| –| 900A Product
+ FR-CC2-H400K-60
FR-F842-09620-E3U6| –| S-N800| –| 900A Product
+ FR-CC2-H400K-60
FR-F842-10940-E3U6| –| S-N800| –| 900A Product
+ FR-CC2-H400K-60
FR-F842-08660-E3U6| –| 1000A Product| –| 1000A Product
+ FR-CC2-H450K-60
FR-F842-09620-E3U6| –| 1000A Product| –| 1000A Product
+ FR-CC2-H450K-60
FR-F842-10940-E3U6| –| 1000A Product| –| 1000A Product
+ FR-CC2-H450K-60
FR-F842-12120-E3U6| –| 1000A Product| –| 1000A Product
+ FR-CC2-H450K-60
FR-F842-09620-E3U6| –| 1000A Product| –| 1200A Product
+ FR-CC2-H500K-60
FR-F842-10940-E3U6| –| 1200A Product| –| 1500A Product
+ FR-CC2-H560K-60
FR-F842-12120-E3U6| –| 1400A Product| –| 2000A Product
+ FR-CC2-H630K-60
Key to DU08 Keypad Display Codes
Function Name | Description | Indication |
---|---|---|
*Error Message 2** | Operation Panel Lock | Operation tried during |
operation panel lock | ||
Parameter Write Error | An error occurred at parameter writing | to |
Copy Operation Error | An error occurred at parameter copying | to |
Error | The RES signal is on or the PU and inverter cannot make normal |
communication
| Stall Prevention (Overcurrent)| Overcurrent stall prevention|
*Warnings 3**
| Stall Prevention (Overvoltage)| Overvoltage stall prevention.
Appears while the regeneration avoidance function is activated.
Electronic Thermal Relay Function Prealarm| The electronic thermal
O/L relay has reached 85% of the specified value
PU Stop| Stop/reset on the operation panel is pressed during external
operation|
| Maintenance Signal Output| The cumulative energization time has
exceeded the maintenance output timer set value|
**Minor Fault| Fan Fault 4| Cooling fan is malfunctioning|
| Overcurrent Shutoff During Acceleration| An overcurrent
occurred during acceleration|
| Overcurrent Shutoff During Constant Speed| An overcurrent occurred
during constant speed operation
| Overcurrent Shutoff During Deceleration or Stop| An
overcurrent occurred during deceleration and at a stop
| Regenerative Overvoltage Shutoff During Acceleration| An overvoltage
occurred during acceleration|
| Regenerative Overvoltage Shutoff During Constant Speed| An
overvoltage occurred during constant speed operation
| Regenerative Overvoltage Shutoff During Deceleration or Stop| **
An overvoltage occurred during deceleration and at a stop
| Inverter Overload Shut-off (Electronic Thermal O/L **Relay)1| The
electronic thermal relay function for inverter element protection is activated
| Motor Overload Shut-off (Electronic Thermal O/L Relay)*1| The
electronic thermal relay function for motor protection is activated
| Fin Overheat**| The heatsink overheated|
*Major Failures 5**
| Instantaneous Power Failure Protection| An instantaneous power
failure occurred at an input power supply|
Undervoltage Protection| The main circuit DC voltage became low|
Input Phase Failure| One of the three phases on the inverter input side
opened
Stall Prevention| The output frequency dropped to 0.5Hz as a result of
deceleration due to excess motor load|
| Output Side Earth (Ground) Fault Overcurrent Protection| An earth
(ground) fault occurred on the inverter’s output side
| Output Phase Failure Protect.| One of the three phases on the inverter
output side opened
| External Thermal Relay *Operation 6| The external thermal relay
connected to the terminal OH was operated
| PTC Thermistor Operation| The motor overheat status is detected for
10s or more by the external PTC thermistor input connected to the terminal AU
| ****HC Unit Alarm| An alarm occurred in the option card or an AC power
supply is connected to the R/L1, S/L2, T/L3 when the high power factor
converter connection is set
| Functional Option Error| A communication error occurred in the
communication option
| Option Card Disconnection| Card is disconnected or misconnected|
| Parameter Storage Device Alarm| Operation of the element where
parameters are stored became abnormal (control circuit board)
| ****PU Disconnection**| A communication error between the PU and
inverter occurred, the communication interval exceeded the permissible time
during the RS-485 communication with the PU connector, or communication errors
exceed the number of retries during the RS-485 communication
Notes:
- Resetting the inverter initializes the internal thermal integrated data of the electronic thermal relay function.
- The error message shows an operational error. The inverter output is not shut off.
- Warnings are messages given before major failures occur. The inverter output is not shut off.
- Minor faults warn the operator of failures with output The inverter output is not shut off.
- When major failures occur, the protective functions are activated to shut off the inverter output and output the alarms.
- The external thermal operates only when the OH signal is set in Pr. 178 to Pr. 189 (input terminal function selection).
FR-F800 Options and Accessories
Model Number
| Type|
Description
---|---|---
FR-A8AX| I/O| 16 Bit Digital Input Card
FR-A8AY| I/O| Digital Output / Extended Analog Output Card
FR-A8AR| I/O| Relay Output Card
FR-A8AC| I/O| A/F800 120V Control Option
FR-A8AN| I/O| F/A800 4-20mA I/O Card
FR-A8NC| Communication| CC-Link Communications Card
FR-A8ND| Communication| DeviceNet Communications Card
FR-A8NP| Communication| Profibus DPV0 Communications Card
A8NDPV1| Communication| Profibus DPV1 Communications Card
FR-A8NF| Communication| FL-Net Communications Card
A8N-XLT| Communication| Multi-protocol RS-485 Communications Card
A8NEIP-2P| Communication| EtherNET IP Communications Card
A8NPRT-2P| Communication| Profinet Communications Card
A8NECT-2P| Communication| EtherCAT® Communications Card
A8NETH-2P| Communication| Multi-protocol EtherNET Communications Card
FR-A8NCE| Communication| CC-Link IE Communications Card
A8NC-CON| Communication| CC-Link Communications Card and Connectors
FR-LU08| Accessory| Liquid Crystal Operation Panel
FR-PU07| Accessory| Parameter Unit
FR-PU07-01| Accessory| Parameter Unit (HVAC type)
FR-PU07BB-L| Accessory| Parameter Unit with Battery Back-up
FR-CB201| Accessory| Parameter Unit Connection Cable 1M
FR-CB203| Accessory| Parameter Unit Connection Cable 3M
FR-CB205| Accessory| Parameter Unit Connection Cable 5M
FR-ADP| Accessory| Keypad Adaptor Unit for connecting FR-DU08
FR-A8TAT| Accessory| Control Terminal Block Adaptor
FR-A8TR| Accessory| Screw Terminal Block Option
FR-HC2| Accessory| Harmonic Suppression Controller
FR-HEL| Accessory| DC Link Choke 240V
FR-HEL-H| Accessory| DC Link Choke 480V
FR-HEL-C| Accessory| DC Link Choke 600V
FR-Configurator2| Software| Software Setup Utility for 800 Series
Third party marks and brands are the property of their respective owners.
MITSUBISHI ELECTRIC AUTOMATION, INC.
500 Corporate Woods Parkway, Vernon Hills, IL 60061
Ph 847.478.2100
Fx 847.478.2253
us.MitsubishiElectric.com/fa/en
February, 2022
©2022, Mitsubishi Electric Automation, Inc.
Specifications subject to change without notice
All rights reserved
L-VH-04069
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>