BaLDR B0359WST2H2PR-V1 Wireless Color Weather Station with Moon Phase User Manual

June 5, 2024
BALDR

BaLDR B0359WST2H2PR-V1 Wireless Color Weather Station with Moon Phase

BaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-with-Moon-Phase-
PRODUCT

We thank you for your purchase of Baldr wireless color weather station with moon phase.It has been designed and constructed using innovative components and techniques to enable the perfect display. Please read the instructions carefully to become familiar with the properties and functions before you use the unit.

For the start-up of this device:

  • Main unit by Ac adaptor (included) and 1x CR2032 (included)
  • Sensor by 2 x AA batteries (not included)

OVERVIEW

MAIN UNIT

BaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-with-Moon-Phase-
fig1

  1.  Temperature and humidity of Channel 1/2/3

  2.  Max/min record of Channel 1/2/3

  3.  Indoor temperature and humidity

  4.  Max/min record of indoor temperature and humidity

  5.  Three comfort level indication

  6.  Weather forecast Weather forecast for next 12-24 hours

  7.  Barometric Pressure Barometer display in mmHg, inHg or hPa/mb

  8.  Calendar display Weekdays in 7 languages

  9.  Current time 12/24 hour format selectable

  10.  Channel scan

  11.  Frost-point warning

  12. snooze” button

  13. “ SET ” button
    Switch C/F or enter into time setting

  14. “ MEM ” button

  15. Check or clear Max/min record

  16. “ CH ” button Switch channel or clear sensors data and re-registration

  17. “ ▲” button
    Indoor temperature/humidity and barometric calibration or Increase the data

  18. “ ▼/RCC ” button
    RCC function or decrease the data

  19. “ ” button
    Check alarm time, turn on/off alarm, enter into alarm setting

  20.  Stand bracket

  21.  Hanging Hole

  22.  Battery Compartment

Notes:

  1.  The default year is 2020, if the weekday display is incorrect . Please confirm year was set correctly. (for manual setting only)
  2. The CR2032 cell battery is for memory function (included). Please do not used as power supply. If you need to replace the cell battery, please take out the part device as shown in the figure below, load new battery matching the polarity(+and-).BaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-with-Moon-Phase-fig2

WARNING: THIS PRODUCT CONTAINS A BUTTON-CELL BATTERY. IF SWALLOWED, IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS.SEEK MEDICAL ATTENTION IMMEDIATELY IF INGESTED.

OUTDOOR SENSOR

BaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-with-Moon-Phase-
fig3

  1.  Signal light
  2.  Battery compartment
  3.  Hanging hole
  4.  Channel 1-2-3 switch

FEATURES

  •  Clear color LCD display
  •  WWVB atomic time
  •  Weather forecast for next 12-24 hours with barometer
  •  Measures in/out humidity and temperature (℉/℃)
  •  Up to 3 RF channels for outdoor sensors (only one sensor included)
  •  Max/min record of temperature & humidity
  •  Comfort level indication
  •  Indoor temperature rang: 14℉~122℉(-10℃~50℃)
  •  Outdoor temperature range:-40℉~140℉(-40℃~60℃)
  •  In/outdoor humidity range: 1%-99%
  •  Calendar, alarm and snooze function
  •  Time display in 12/24H
  •  Calendar function with Month/Date or Date/Month display format selectable
  •  White backlight with dimmer

PACKAGE CONTENT

Following contents are included in the package:

  • 1 x Weather Station Main Unit
  • 1 x Remote Sensor
  • 1 x AC Adaptor
  • 1 x CR2032 Cell Battery
  • 1 x User Manual

GETTING START

BALDR recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.

MAIN UNIT INSTALLATION
Remove the cell battery’s Insulating strip, then plug the adaptor to a powered outlet.

SENSOR INSTALLATION

  1.  Remove the battery compartment cover;
  2.  Insert 2 x AA batteries in each sensor matching the polarity (+and-);
  3.  Replace the battery cover.

SENSOR SETUP

  • Switch the Channel 1-2-3 of the senor to any channel you want. For example, you can set to Channel 1 for the sensor. But please ensure the main unit are set to the same channel before synchronization. (Special note: Press “CH” button on the main unit to set the channel.The setting order is CH1–CH2–CH3–Channel scan (from CH1 to CH2 to CH3,10 seconds intervals),you must select the same number choices for both the sensor and the main unit in order for the units to synchronize).
  • Power the main unit prior to load the batteries of sensor.

Note:

  1.  Main unit will auto receive outdoor signal after power on, the receiving status will last for max 3 minutes. The receiving antenna signal will flash. If no signal received in 3 minutes, it will stop receiving outdoor signal.
  2.  If the main unit is out of 3 minutes’ signal receiving window, you can press and hold the “ CH ” button to enter signal receiving again.

MAIN UNIT SETUP
When power on or reset, LCD will full display for 3 seconds with “BI” sound. Then display Indoor temperature and humidity, barometric pressure with 100% backlight brightness.

RF Signal Receiving
After power on, It will start receiving outdoor sensor’ signal for 3 minutes. If signal received within 3 minutes or receiving window ends, it will enter into DCF signal receiving window.

DCF Signal Receiving

  1.  After RF signal receiving, it will start searching radio signal for 7 minutes with the antenna symbol “ ” displaying on screen. Meanwhile, the backlight brightness will automatically adjust to 5% (default brightness: 100%).
  2.  Once signal received, the main unit will display the received time/month/date/weekday with symbol “ ” displaying on screen.
  3.  Daily RCC signal receiving: there are regular radio signal receiving at UTC 7:00AM,8:00AM, 9:00AM, 10:00AM, 11:00AM each day. It starts receiving signal at UTC 7:00AM everyday. For each day, once signal received at any one receiving time, it will stop receiving signal that day.
  4.  Manual receiving: press and hold “ ▼/RCC ” button to enter RCC signal receiving.
  5.  During receiving, press “ ▼/RCC ” button to exit RCC receiving.

*RCC symbol display:

  1.  When receiving signal , RCC icon will be flashing by“1HZ”.
  2.  When signal successfully received, LCD will display complete RCC icon and exit RCC receiving.
  3.  If no signal is received, the RCC icon will disappear.

Manual Settings

  1. After signal received, if there is no need for other settings, you can just finish reading here. If there is other setting requirements. Please check the following steps. Or if there is no signal received, ou can follow bellow steps for manual setting.

  2. Press and hold “ SET ” button to enter into setting, press “ SET ” button to skip setting steps or go to the next setting option.
    *Tips: press and hold “▲” or “ ▼/RCC ” button will quickly change the value by 8 steps.

  3. Press “ SET ” to select the RCC. Default setting : ON. Press “▲” or “ ▼/RCC ” button to select OFF or ON.

  4.  Press “ SET ” to select Time Zone. Default setting : -5(EST). Press “▲” or “ ▼/RCC ” button to select time zone: AST(-4),EST(-5),CST (-6),MST(-7),PST(-8),AKT(-9),HAT(-10) optional.

  5.  Press “ SET ” to select DST ON/OFF. Default setting : ON. Press “▲” or “ ▼/RCC ” button to select DST ON if you do observe Daylight Saving Time.
    DST symbol display:

  6.  Select “DST ALWAYS” ,means DST function is always on all the year round.

  7.  Select “DST ”,means DST function will be on during daylight saving time.

  8.  Select “DST OFF”, means DST function is off. 

  9. Press “ SET ” to select 12/24H Time Format. Default setting :12 H. Press the “▲” or “ ▼/RCC ” button to select 12H or 24H.

  10.  Press “ SET ” to select Hours. Press “▲” or “ ▼/RCC ” button to adjust the value.

  11.  Press “ SET ” to select Minutes. Press “▲” or “ ▼/RCC ” button to adjust the value.

  12.  Press “ SET ” to select Year. Press “▲” or “ ▼/RCC ” button to adjust the value.

  13.  Press “ SET ” to select Month&Date display format. Default setting : M/D. Press the “▲” or “ ▼/RCC ” button to select M/D or D/M format. (M: Month ,D: Date)

  14. Press “ SET ” to select the Month. Press “▲” or “ ▼/RCC ” button to adjust the value.

  15.  Press “ SET ” to select the Date. Press “▲” or “ ▼/RCC ” button to adjust the value.

  16. Press “ SET ” to select Weekday Language. Default setting :ENG. Press the “▲” or “ ▼/RCC ” button to select languages: GER/ENG/FRE/SPA/ITA/DUT/DAN optional .(German/English/French/Spanish/Italian/Dutch/Danish)

  17. Press “ SET ” to select Beep ON/OFF .Default setting :ON. Press the “▲” or “ ▼/RCC ” button to select ON/OFF.

  18.  Press “ SET ” to select the Barometric Unit. Default setting : inHg. Press “▲” or “ ▼/RCC ” button to select unit: mmHg, inHg or hPa/mb optional.

  19.  Press “ SET ” to confirm and exit.

  20.  During setting, touch top button to save and exit setting.

  21. During setting, if no operation for 20 seconds, it will automatically save and exit setting.

ALARM FUNCTION
Alarm Time & Snooze Setting 

  1. Press and hold “ ” button to enter into alarm time and snooze setting.
  2. Press “▲” or “ ▼/RCC ” button to adjust data; press and hold “▲” or “ ▼/RCC ” button will quickly change the value by 8 steps.
  3. The setting order is: Hour → Minute→Snooze Interval time → Exit.
  4.  Snooze interval time : 5~60 minutes can be set, Default setting : 5 minutes.
  5.  During setting, touch top button to save and exit setting.
  6.  During setting, if no operation for 20 seconds, it will automatically save and exit setting.
  7.   The alarm is default ON after setting the alarm time. Alarm symbol will display on screen.

Alarm ON/OFF Setting

  1.  When in time display mode, press “ ” button to check alarm time. Press “ ” button twice to turn ON/OFF alarm by the ON/OFF of symbol .
  2.  When in alarm time display mode, press “ ” button to turn on/off the alarm by the ON/OFF of symbol .

SNOOZE FUNCTION

  1.  When the alarm is ringing, press any other button except top button to stop the alarm. And the alarm will restart next day.
  2.  Or when alarm is ringing, press the top button to activate snooze function. The alarm will ring again in snooze interval time as you set before. And the “ ” symbol will be flashing on screen to indicate the snooze mode. Press any other button except top button to exit the snooze mode. And the alarm will restart next day.
  3.  When alarm rings, the ascending “Bibi” alarm sound will last for 2 minutes if no operation.

OPERATION GUIDELINES

MAX AND MIN RECORD

  1.  Press “MEM” button to check maximum temperature and humidity, the value will display for 5 seconds.
  2.  Press “MEM” button second time to check the minimum temperature and humidity, the value will display for 5 seconds.
  3.  Press “MEM” button third time will return to standard mode.
  4.  Press and hold “MEM” button will clear the max and min record and reactivate the memory.
  5.  During setting, if no operation for 5 seconds, it will automatically save and exit setting.
  6.  Normally, the Max and Min record will update every 24 hours at 0:00.

TEMPERATURE

  1.  After power on ,the indoor temperature will display automatically, it will update reading each 30 seconds and start to receive outdoor signal which lasts for max 3 minutes.
  2.  Indoor temperature display range:14℉~ 122℉(-10℃~ 50.0℃); for temperature lower than 14℉,the reading will be :“LL.L”; for temperature higher than 122℉,the reading will be :“HH.H”.
  3.  Outdoor temperature display range :-40℉~140℉(-40℃~60℃); for temperature lower than -40℉,the reading will be :“LL.L”; for temperature higher than 140℉,the reading will be :“HH.H”.
  4.  Arrow indication for temperature changes:
    • will display when temperature changes less than 1.8℉ within one hour or compared with last reading;
    • will display when the reading increase by 1.8℉ within one hour or compared with last reading.
    • will display when the reading decrease by 1.8℉ within one hour or compared with last reading.
  5.  Accuracy: For temperature between 32℉~122℉,the accuracy is±1.8℉,if out of this range the accuracy will be ±3.6℉ ; Temperature resolution is 0.1℉(0.1℃).
  6.  Press “SET ” button to switch from Celsius degree to Fahrenheit degree.

HUMIDITY

  1.  After power on ,the indoor humidity will display automatically, it will update reading each 30 seconds and start to receive outdoor signal which lasts for max 3 minutes.
  2.  Humidity display range: 1%-99%;for humidity lower than 1%,the reading will be “1%”;for humidity higher than 99%,the reading will be “ 99%”.
  3. Accuracy: when the temperature is between 68℉~ 78.8℉(20℃~ 26℃) and the humidity is between 40-80%,the accuracy is ±5%,if out of this range the accuracy will be ±8%.
  4.  Arrow indication for humidity changes:
  5. will display when humidity changes less than 5% RH within one hour or compared with last reading.
  6. will display when the reading increase by 5% RH within one hour or compared with last reading.
  7. will display when the reading decrease by 5% RH within one hour or compared with last reading.
  8.  Humidity resolution:1% .

BAROMETRIC PRESSURE

  1.  Barometer range: 25.1-31inHg (646-798mmHg, 850-1050 hPa/mb).
  2.  Arrow indication for barometric pressure changes:
  3. will display when pressure changes less than 2 hPa within three hour or compared with last reading;
  4. will display when the pressure increase by 2 hPa within three hour or compared with last reading.
  5. will display when the pressure decrease by 2 hPa within three hour or compared with last reading.
  6.  Press and hold “SET ” button to switch barometric unit ( please refer to Manual Settings Point 15) .

COMFORT LEVEL INDICATORBaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-
Station-with-Moon-Phase-fig4

WEATHER FORECASTBaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-
with-Moon-Phase-fig5

The weather forecast icon will show after power on. There are 5 kinds of weather modes: Sunny, Sunny To Cloudy, Cloudy, Rainy, Snow. The weather icon displays are based on the hourly calculation of indoor/outdoor temperature & humidity and barometer data. The forecast is for next 12 hours with 70%-75% accuracy.

FROST-POINT ALERT

When current outdoor channel’s temperature is in the range of 32℉~37.22℉(0℃~ 2.9℃),the alert symbol “ ” will be flashing until the temperature reading is higher than 37.22℉; the symbol will keep displaying on screen if temperature is lower than 32℉.

MOON PHASEBaLDR-B0359WST2H2PR-V1-Wireless-Color-Weather-Station-with-
Moon-Phase-fig6

CALIBRATION
Baldr weather stations were calibrated precisely at our manufacturing facility, but if you want the data of this product to be consistent with the reading of the equipment you are more trusted or more used to, you can manually calibrate the indoor temperature, humidity and barometer values.

1. When in time display mode, press and hold “▲” button to enter Calibration mode.
2. Press and release the “SET” button to confirm and move to the next setting: Indoor Temperature →Indoor Humidity→ Barometer
→ Exit.
3. Press “▲ ” or “ ▼/RCC ” button to adjust the value.
4. Indoor temperature calibration range : ±5 ℃ ;
Indoor humidity calibration range: ± 10 %RH;
Barometer calibration range: ±10 hPa.
5. During setting,you can press “MEM” button to clear all correction values.
6. During setting, touch top button to save and exit setting. If no operation for 20 seconds, it will automatically save and exit setting.

ADJUSTABLE BACKLIGHT

  • After powering on, touch “ ” button to adjust the brightness of the backlight.
  • Backlight brightness can be selected from 5%,60%,100% and off.

LOW BATTERY INDICATORS

  • About Outdoor Sensor: When battery indicator shows next to the outdoor temperature, replace batteries in your outdoor sensor.
  • About Cell Battery in Main Unit: The CR2032 cell battery is only for memorizing the setting during sudden power outage. When battery indicator shows next to your Indoor Temperature, replace battery.

TROUBLE SHOOTING

Problem Possible Solution

Outdoor reading is flashing or showing dashes

| Flashing of the outdoor reading is generally an indication of wireless interference.

1. Bring the sensor and main unit indoors, side by side and remove batteries from each.

2. Make sure the CH 1-2-3 switch on both units match.

3. Reload batteries in outdoor sensor.

4. Reload batteries in main unit.

5. Let both units sit within a couple feet of each other for a few minutes to gain a strong connection before taking sensor to outdoor area.

Problem Possible Solution

No outdoor sensor reception

| 1. Reload the batteries of both outdoor sensor and main unit. Please refer to the SENSOR SETUP section.

2. Relocate the main unit and/or the out- door sensor. The units must be within 100m(328ft) of each other.

3. Make sure both units are placed at least

0.9 m (3 ft) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).

4. Use standard alkaline batteries. Do not use heavy duty or rechargeable batteries. NOTE: It may take a few minutes for main unit and sensor to synchronize after batteries are reloaded.

Inaccurate temperature/ humidity| Make sure both the main unit and sensor are placed out of direct sunlight and away from any heat sources or vents.
“HH.H/LL.L” display in indoor and/or outdoor temperature| If the temperature is higher than the detec- tion range, “HH.H” will display on screen for indication; if lower than the detection range, “LL.L” will display on screen for indication.
If your BALDR product does not operate properly after trying the troubleshooting steps, please contact the seller on your order page or shoot an email to: service@baldr.com.

PLACEMENT INSTRUCTION

BALDR sensors are sensitive to surrounding environmental conditions. Proper placement of both the main unit and outdoor sensor are critical to the accuracy and performance of this product.

Main Unit Placement
Place main unit in a dry area free of dirt and dust. To help ensure an accurate indoor temperature measurement, be sure to place the Main unit away from heat sources or vents.

Outdoor Sensor Placement
Sensor must be placed outside to observe outdoor conditions. Sensor is water resistant for water splashes and is designed for general outdoor use, however, to extend its life place the sensor in an area protected from direct weather elements. The best location is 1.2 to 2.4 meters (4 to 8 feet) above the ground with permanent shade and plenty of fresh air to circulate around the sensor.

Important Placement Guidelines

  • The distance between main unit and transmitter should be at least 1.5~2 meters (5~6.5 feet) away from any interfering sources such as computer monitors or TV sets.
  • To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
  • Please do not use other electrical products such as headphones or speakers operating on the same signal frequency.
  • Neighbors using electrical devices operating on the same signal frequency can also cause interference.

PRECAUTIONS

  • Do not clean any part of the product with benzene, thinner or other solvent chemicals. When necessary, clean it with a soft cloth.
  • Never immerse the product in water. This can cause electrical shock and damage the product.
  • Do not subject the product to extreme force, shock, or fluctua-tions in temperature or humidity.
  • Do not tamper With the internal components.
  • Do not mix new and old batteries or batteries of different types.
  • Do not mix alkaline, standard or rechargeable batteries with this product. Remove the batteries if storing this product for a long period of time.
  • Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

WARRANTY

BALDR provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.
Warranty service can only be performed by our authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to us, or our authorized service center.
The warranty covers all defects in material and workmanship with the following specified exceptions:(1) damage caused by accident, unreasonable use or neglect (including the lack or reasonable and necessary maintenance); (2) damage occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of any accessory or decorative surface;(4) damage resulting from failure to follow instructions contained in your owner’ s manual.
This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances.
To receive warranty service, the purchaser must contact with BALDR nominated service center for the problem determination and service procedure.
Thank you for your choice of BALDR products!