MEEC TOOLS 015256 1300W 80l/min Hydrophore Pump Instruction Manual

June 6, 2024
MEEC TOOLS

MEEC TOOLS 015256 1300W 80l/min Hydrophore Pump

SAFETY INSTRUCTIONS

  • This product can be used by children from 8 years and upwards and by persons with physical, sensorial or mental disabilities, or persons who lack experience or knowledge, if they are supervised or receive instructions concerning the safe use of the product and understand the risks involved with its use. Do not allow children to play with the product. Do not allow children to clean or maintain the product without supervision.
  • Keep children under supervision to make sure they do not play with the product. Do not allow children to clean or maintain the product without supervision.
  • Familiarise yourself with the controls on the product and how to use them. Read all the instructions and safety instructions before use. Failure to follow all the instructions and safety instructions can lead to the risk of electric shock, serious personal injury and/or material damage.
  • Contact the retailer or qualified personnel if you have any problems or questions.
  • Store these instructions so that they are readily available for everyone who uses the product. These instructions should be enclosed with the product if it is sold or passed on.
  • Do not make any modifications to the product. Only use accessories recommended by the manufacturer.
  • The product must only be used for its intended purpose and in accordance with these instructions. The product must only be used for its intended purpose and in accordance with these instructions, otherwise there is a risk of personal injury and/or material damage.
  • The manufacturer cannot accept liability for personal injury and/or material damage resulting from improper use.
  • A damaged cord or plug must be replaced by an authorised service centre or qualified person to ensure safe use.
  • Do not use the product if it is damaged. Always check the power cord, plug and casing before use. If the product is damaged, or not working properly, it must be repaired or discarded.
  • Pull out the plug immediately if the power cord or product gets damaged or stops working properly, otherwise there is a risk of electric shock.
  • Qualified personnel must carry out repairs. Imperfect repairs can result in a risk of electric shock, serious personal injury and/or material damage.
  • Do not pull the power cord to pull out the plug.
  • Do not allow the power cord to hang over the edge of a table or worktop, or to come in contact with hot surfaces.
  • Avoid kinking or bending the power cord.
  • If an extension cord is used the cross­sectional area of the wires must be dimensioned for the power supply to the product.
  • If the product is used outdoors, only use an extension cord approved for outdoor use.
  • The product is not intended to transport water for human consumption.
  • Do not use the product to transport corrosive, flammable or explosive substances such as petrol or other petroleum products, nitrogenous liquids, grease, oil, salt water or waste water from toilets, or liquid that has a higher viscosity than water.
  • The temperature of the pumped liquid must not exceed 35° C.
  • Keep this product out of the reach of children.
  • Do not use the product if there are any persons in the water.
  • Make sure the product does not suck up aquatic animals, such as fish.
  • Pay attention to the risk of contaminating the liquid as a result of leaking lubricant.
  • Protect electrical connections from moisture.
  • Do not expose the product to temperatures below 0°C. Make sure that the product is not run without liquid.
  • Do not pump aggressive liquids or abrasive material.
  • Do not pull the power cord or float switch cord to move the product, and do not use them to secure the product from moving.
  • The product is only intended for household use and is not suitable for commercial purposes.
  • The manufacturer cannot accept liability for personal injury or material damage resulting from improper use.
  • The product is intended to be used with a domestic water tank. When the pump is used to boost pressure, the maximum inlet pressure to the pump (1.0 bar) must not be exceeded.

Electrical safety

  • Check that the mains voltage corresponds to the rated voltage on the type plate.
  • If the product is used outdoors, only use an extension cord approved for outdoor use. The product must not be put in water.
  • If an extension cord is used the cross­sectional area of the wires must be dimensioned for the power supply to the product.
  • If an extension cord is used on a reel, pull out the full length of cord.

WARNING!
The product must be connected to a mains with a residual current device of max 30 mA for use in a pool or garden.

SYMBOLS

TECHNICAL DATA

MEEC-TOOLS-015256-1300W-80l-min-Hydrophore-Pump-4

  1. Sound pressure level
  2. Measured sound power level
  3. Guaranteed sound power level

Always wear ear protection.
The declared values for vibration and noise, which have been measured according to a standardised test method, can be used to compare different tools with each other and for a preliminary assessment of exposure. The measurement values have been determined in accordance with EN ISO 3744:1995.

WARNING!
The actual vibration and noise level when using tools may differ from the specified maximum value, depending on how the tool is used and the material. It is therefore necessary to determine which safety precautions are required to protect the user, based on an estimate of exposure in actual operating conditions (taking into account all stages of the work cycle, e.g. the time when the tool is switched off and when it is idling, in addition to the start- up time).

DESCRIPTION

Maintenance-free hydrophore pump adapted for clean water up to 35°C. The robust 50 litre tank helps to deliver a constant pressure, while also reducing wear because the pump does not have to start/stop as often.

MEEC-TOOLS-015256-1300W-80l-min-Hydrophore-Pump-2

  1. Water inlet
  2. Water outlet
  3. Cap over refill
  4. opening Pump
  5. Mechanical pressure switch
  6. Pressure gauge
  7. Pressure tank

USE

NOTE

  • Always check before use that the suction line is airtight. Foam can accumulate in the suction hose if there is leakage, which will prevent the product from working properly.
  • All the connections to the pump must be sealed to reduce the risk of air penetrating into the system.
  • Threads on metal pipes must be sealed with jointing tape.
  • All parts of the suction line should be installed by qualified personnel.
  • The material diameter of the suction line should be at least 25 mm. The suction line should be made of material that does not squeeze at underpressure and which is resistant to bending.
  • The suction line should be installed so that it is not subjected to mechanical stress. Fit a suitable filter if the pumped liquid is contaminated or turbid.
  • The pump’s suction line should be as short as possible – long suction lines reduce the capacity of the pump.
  • The suction line should run upwards all the way to the pump, to avoid air becoming stationary in the line.
  • Make sure that the inlet on the suction line is always covered with water.
  • All parts of the outlet line should be pressure resistant.
  • All parts of the outlet line should be installed by qualified personnel.
  • It is recommended to install a non-return valve to prevent return flow, which can cause the water in the product and the suction line to empty when the product is not running.

INSTALLATION

The product can be installed in a piping system that supplies domestic water. In such cases the product should be connected to the piping system with a flexible hose, to avoid transmitting vibrations to the piping system.

  • For permanent installation, secure the product to the surface with four screws.
  • If the product is used for a pond or pool it should be installed in such a way as to prevent overflowing, and so that it cannot drop.
  • The product should be protected from the weather. If the product is installed indoors the floor should be water resistant or provided with a floor drain.

WARNING!
Risk of personal injury if components that cannot withstand the pressure are used. Failure to carry out the installation correctly can cause the outlet line to burst and liquid to spray out, resulting in personal injury and/ or material damage.

IMPORTANT:

  •  The product is not intended for distribution of drinking water, only to transport water for a toilet or washing machine.
  •  The product must be filled with water before it starts. Water does not need to be refilled during long term use. Do not leave the product unattended when running. Dry running can result in material damage.

MAINTENANCE

WARNING!
Pull out the plug before cleaning and/or maintenance.

  • Do not attempt to carry out any measures other than as described in these instructions for maintenance and troubleshooting. Any problems not described in these instructions should be carried out by qualified personnel.
    Only use accessories and spare parts recommended by the manufacturer.

  • The use of other accessories and parts can result in a risk of personal injury and/or material damage. It will also invalidate the warranty.

  • All the seals should be replaced if the product is dismantled.

TROUBLESHOOTING

The troubleshooting guide is used to identify the causes of common problems and how they can be rectified. Contact the dealer if the problem can not be rectified with the help of the troubleshooting chart. The warranty does not cover damage resulting from repairs or attempted repairs carried out by unauthorised persons. See troubleshooting guide on next page.

Problem Cause Action
 

Power supply disconnected.

| Check the power cord, plug, power point and fuses.
 | The power cord or plug is damaged.| Allow an authorised electrician to check and if necessary repair the product.
 |  | Switch off the product and pull out the plug, otherwise the mechanical seal can be damaged.

The product does not work, or suddenly stops when running.

| The mechanical seal seizes.| Allow the product to cool and then turn the axle with a Phillips screwdriver, placed in the slot in the end of the axle. When the axle rotates, plug in the plug and start the product.

The pressure switch has tripped as a result of high pressure in the outlet line. The mechanical seal seizes. The power cord or plug is damaged.

| Switch off the product and pull out the plug, otherwise the mechanical seal can be damaged.

Allow the product to cool and then turn the axle with a Phillips screwdriver, placed in the slot in the end of the axle. When the axle rotates, plug in the plug and start the product.

 | The lifting height to the drain cock is proportionate is a higher pressure than the tripping pressure for the pressure switch .|

Adjust the pressure switch setting, if necessary.

MEEC-TOOLS-015256-1300W-80l-min-Hydrophore-Pump-1

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>