AUDIOropa Xepton T-1R Stationary transmitter User Manual

June 6, 2024
AUDIOropa

AUDIOropa Xepton T-1R Stationary transmitter

Introduction

Thank you very much for purchasing the »exception« communication system! You have chosen a modern and reliable system. Please read this manual carefully to be able to set up the unit correctly and to familiarise yourself with all of the features of the system. Septon« is an ideal system for application within groups – ranging from simple dialogue to interpreter-, team-teaching- and conference systems. Being slim and lightweight in design, it combines quality and versatility with easy use and state-of-the-art radio technology.

Scope of delivery xepton T-1R Please check if all of the following components are included:

  • xepton T-1R
  • USB power lead
  • USB power supply
  • User manual
  • Warranty card

Should any parts be missing, please contact your dealer or the manufacturer directly.

Main Features

  • Worldwide compatibility due to restriction-free 2.4 GHz transmission
  • Supports an unlimited amount of receivers »xepton RX-1«
  • 40 selectable channel groups
  • The »xepton T-1R« can be used in two-way communication with two »xepton TRX-1« transceiver units.
  • Large signal range of up to 400 m
  • Completely digital crystal-clear sound quality
  • Microphone sensitivity adjustable in 5 levels
  • 9 selectable levels of volume
  • Can be powered with a portable USB power pack

Available accessories

  • TRX-1 Tranciever A-5200-0
  • RX-1 Receiver A-5221-0
  • HSB-01 microphone-headset A-5270-0
  • EBB-01 microphone-headset A-5271-0
  • EHR-01 microphone-headset A-5272-0

xepton T-1R Transmitter

Controls and displays

AUDIOropa Xepton T-1R Stationary transmitter Fig1

How to use

  • Power ON / OFF Use the ON/OFF switches to switch the device on. The illuminated LC display indicates the default volume setting »VOL 03«. Use the ON/OFF switch again to switch the device off.

Group selection

Switch the device on and press the MODE button for 3 seconds. The symbol »GRP« in the display will blink. Select a group number of your choice between »00« and »39« by pressing the and -buttons. After the selection, wait for 3 seconds to set the selected group number. Transmitters and receivers must be set to the same group number if they are to communicate with each other.

ID selection Within a group, each transmitter needs to have a different ID from »00« to  » 99«. Every group must have a transmitter set to the master- ID »00«, which defines it as the master transmitter of the group. In this case, »MASTER« and » TALK« are indicated on the display. To set the ID, continue as follows: On the powered-up device, press and hold the MODE button for 3 seconds. The symbol »GRP« on the display will blink.

Press the MODE button again. The symbol »ID« will start to blink. By using the and -buttons, select an ID from 00 to 99, while taking care that each device within the group has its own number. After the selection, wait for 3 seconds to set the selected ID number.

Volume up / down

The volume can be adjusted through 9 levels. On the powered-up device, press the and -buttons to adjust the volume between 01 (low) and 09 (high) as desired.

Monitoring function On / Off

The monitoring function enables you to hear your own voice over the system. Proceed as follows if you wish to activate the monitoring function: On the powered-up device, press and hold the MODE button for 3 seconds. The symbol »GRP« in the display will blink. Press the MODE button two times. The »SO« symbol in the display blinks. By using the and -buttons, select »SO« to activate the monitoring function or SF to deactivate it. After the selection, wait for 3 seconds to set the selected function.

Please note: The default setting is »SF« (monitoring deactivated).

Microphone sensitivity

The microphone sensitivity can be adjusted through 5 levels according to environmental requirements: On the powered-up device, press and hold the MODE button for 3 seconds. The symbol »GRP« in the display will blink. Press the MODE button three times. The »C1« symbol in the display blinks. By using the and -buttons, select between C1 (low sensitivity) and C5 (high sensitivity).

Please note: The default setting is C3.

Audio output high/low

Apart from the volume control, it is possible to adjust the basic audio output level. A higher audio output will raise the maximum volume – this might be re- quired in noisy surroundings. On the powered-up device, press and hold the MODE-button for 3 seconds. The symbol »GRP« in the display will blink. Press the MODE button four times. The »UH« symbol is shown in the display. By using the and -buttons, select UH (high output) or UL (normal output). After the selection, wait for 3 seconds to set the selected output level.

Please note: Selecting »UH« can cause white noise and should only be used in loud environments. We recommend the default setting »UL«.

Power supply

The transmitter is powered over the USB connection. The device can be powered by a regular USB power pack for mobile phones and can hereby be used in a portable manner. Connect the power pack to the USB connector on the rear of the device.The power consumption of the device is approx. 200mA.

Applications

Transmitting with T-1R and receiving with RX-1

An unlimited amount of RX-1 receivers can be used to receive the transmission of the T-1R. All devices must be set to the same channel group number.

Two-way communication with transmitter T-1R and two TRX-1 transceivers

It is possible to have two-way communication between the T-1R transmitter and two TRX-1 transceivers. All devices must be set to the same channel group number and each device must have its own ID number, with one device having the master-ID »00«.

Two-way communication with transmitter T-1R, two TRX-1 transceivers and RX-1 receivers

It is possible to have two-way communication between the T-1R transmitter and two TRX-1 transceivers.An unlimited amount of RX-1 receivers can receive the transmission. All devices must be set to the same channel group number and each transmitter device must have its own ID number, with one transmitter device having the master-ID »00«.

Pin-layout XLR

4 Pin XLR on the front panel

3 Pin XLR on the rear panel

Specifications xepton T-1R

  • Device type Transmitter
  • Dimensions 45 x 220 x 220 mm (H x W x D)
  • Weight 1360 g
  • Frequency type ISM 2403 – 2480 MHz
  • Transmission mode ISM 2.4 GHz FSK modulation with frequency hopping
  • Transmission power Maximum 10 mW
  • Voice codec 16bit / 8 KHz
  • RX-sensitivity -95 dBm
  • Latency < 35 ms
  • Data rate 2 Mbps
  • Frequency bandwidth 2 MHz
  • Power USB 5V/DC / 1A
  • Power consumption 200 mA
  • Range up to 350 m
  • Frequency response 50 Hz – 7 kHz

Conformity

This device complies with the following EC directives:

  • 2011 / 65 / EC RoHS-directive
  • 2012 / 19 / EC WEEE-directive
  • 2014 / 53 / EC RED-directive

Compliance with the directives listed above is confirmed by the CE seal on the device. The complete CE compliance declaration is available on the internet at www.humantechnik.com. Specifications subject to change.

Maintenance and care

All »xepton«-devices do not require any maintenance. If they become dirty, simply wipe them clean with a soft, damp cloth. Never use spirits, thinners or other organic solvents. Do not expose them to full sunlight. In addition, they must be protected against excessive heat, moisture and severe mechanical shocks. Note: These products are not protected against splash water. Do not place any containers filled with water, such as flower vases, or anything with an open flame, such as a lit candle, above or near the products.

Warranty

All »xepton«-devices are very reliable products. Should a malfunction occur despite the unit having been set up and operated correctly, please contact your dealer or the manufacturer directly.
This warranty covers the repair of the product and returning it to you free of charge. It is recommended that you send in the product in its original packaging, so keep the packaging for the duration of the warranty period.
The warranty does not apply to damage caused by incorrect handling or attempts to repair the unit by unauthorized persons (destruction of the seal on the unit). Repairs will only be carried out under warranty if the completed warranty card is returned accompanied by a copy of the dealer’s invoice/till receipt. Always specify the product serial number in any event.

Disposal of used electrical and electronic units (applicable in the countries of the European Union and other European with a separate collection system). The symbol on the product or the packaging indicates that this product is not to be handled as ordinary household waste but has to be returned to a collecting point for the recycling of electrical and electronic units. You protect the environment and health of your fellow man by the correct disposal of this product. Environment and health are endangered by incorrect disposal. Material recycling helps to reduce the consumption of raw materials. You will receive further information on the recycling of products from your local community, our communal disposal company or your local dealer.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals