Honeywell Home T4M Programmable Modulating Thermostat Installation Guide

June 6, 2024
Honeywell Home

Honeywell Home T4M Programmable Modulating Thermostat

Quick Start Installation Guide

Compatible with OpenTherm appliances only. Not compatible with 230V boilers, zone valve applications or 230V electric heating.

Installation in 3 steps…



|

Must be installed by a competent person.
Toensure your safety make sure themains power is switched OFF before accessingwiring.

---|---

32318058-001 B

1 Wire the Thermostat

Find a suitable wall location away from draughts, direct sunlight or other heat sources, and where cables can be run from the boiler to the thermostat.

A) Separate the wallplate from the thermostat, and using a screwdriver open the wallplate terminal cover to connect wires.

B) Connect wires according to wiring diagrams and clip the cover closed.

OpenTherm Boiler

| To prevent a short circuit from a loose wire –

  • When using multi-core cables: Only remove enough outer insulation to allow secure fixing ofthe coresinto the terminal block.
  • When using single core cables: Secure them together with a cable tie as close as possible to the terminal block.

---|---

Power Up and Test

Power Up the Heating System and do a quick functional test on the thermostat to check that it switches the boiler.

Configure the System

Specific settings for the thermostat and heating system can be configured in the advanced menu.
Press and hold and then buttons together until the display changes (approx. 3 seconds).

A) Press and buttons tonavigate through the parameter list

B) Press and buttons to change a parameter

C) Press buttonto savethe change (or press  ****to cancel the change)

D) Press button to exitadvanced menu and save any changes

OpenTherm Data ID’s

N ° Description Settings (default in bold)
OT1 Low load control 0 = Off, 1 = On
OT2 Control setpoint 5 – 99°C
OT3 Supply water temperature 5 – 99°C
OT4 Returnwatertemperature 5 – 99°C
OT5 Max. supply water temperature 5 – 99°C
OT6 Hot water temperature 5 – 99°C
OT7 Hot water set point 5 – 99°C
OT8 Actual power 0 – 99%
OT9 Water pressure 0.0 – 9.9
OT10 OTC control 0 = Off, 1 = On
OT11 OTC curve 4 – 40 ( 16 )
OT12 Room compensation 0 = Off, 1 = On

Parameters

Description Settings (default in bold)
1 LA Language 1 = EN, 2 = NL, 3 = DE, 4 = FR, 5 = ES
4 LL Lower Temperature Limit 5 – 21 (°C)
5 UL Upper Temperature Limit 21 – 35 (°C)
6 SO Schedule options 1 = 7 day (different schedule each day of the week)

2 = 5 + 2 day (weekday + weekend schedule)
3 = 1 day (same schedule every day)
7 NP| Number of periods per day| 4 or 6
8 SS| Wired Remote Sensor| 0 = No Remote Sensor, 1 = Wired Remote Sensor
9 LC| Fail Safe mode| 0 = Boiler off, 1 = Boiler 20% on / 80% off
10 BL| Backlight| 0 = Off, 1 = On (only on demand)
11 CL| Clock Format| 0 = 24 hr, 1 = AM/PM
12 DS| Daylight Saving time change| 0 = Off, 1 = Auto
13 TO| Temperature Display Offset| +/-1.5°C
15 SD| Restore Schedule Defaults| 0 , 1 = reset
16 FS| Restore Factory Settings| 0 , 1 = reset

Troubleshooting

What’s happening? What it could mean… How to fix it…
Thermostat display is blank No power to heating system Check heating system

is powered
Faulty wiring connection| Check wiring at thermostat and boiler terminals
Display = | Faulty temperature sensor| Replace thermostat or check wiring to remote temperature sensor if fitted
Thermostat shows heat demand but boiler doesn’t respond| Boiler (water) already at temperature| Normal behaviour – wait for water temperature to drop
Faulty wiring connection| Check wiring at thermostat and boiler terminals

Conforms to protection requirements of the following directives:
EMC: 2014/30/EU and LVD: 2014/35/EU

ErP: Class VI (+4%), (EU) 811/2013


WEEE Directive 2012/19/EC – Waste Electrical and Electronic Equipment directive
At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.

Ademco 1 GmbH Hardhofweg 40 74821 Mosbach
Phone: +49 1801 466 388
info.de@resideo.com
homecomfort.resideo.com

@2020 Resideo Technologies, Inc.
All rights reserved The Honeywell Home trademark is used under license from Honeywell International Inc. This product is manufactured by Resideo Technologies, Inc and its affiliates.