MUNBYN IPS01 Digital Shipping Postal Scale User Manual

June 6, 2024
MUNBYN

MUNBYN logo Postal Scale

MUNBYN IPS01 Digital Shipping Postal Scale

PREFACE

This user manual is designed to assist in the safe and trouble-free use of the device. The product is designed and manufactured in accordance with strict technical guidelines, using state-of-the-art technologies and components. User manual download link: htts://munbyn.biz/901urn

PRODUCT INTRODUCTION

MUNBYN IPS01 Digital Shipping Postal Scale - productMUNBYN IPS01 Digital Shipping Postal Scale -
product2

TECHNICAL DATA

Parameter description Parameter value
Product name Postal/letter Scale
Model IPS01
Load capacity (kg) 30kg/66Ib
Unit g; lb; oz; kg; Ilioz;
Button On/Off/rare Button; MODE Button; PCS Button.
Minimum weighing weight SIIg
Standby time 180s (default) (When the scale is powered on, the scale will not

automatically shut down)
Power supply| 1.5Vx3AAA or AC adapter (110-240V AC to 6V DC)

DEVICE USAGE

3.1 Weighing
Weighing is the most basic function of this scale, and it can be used to weigh up to 30kg. To weigh, follow the steps below:

  1. Place the scale on a flat surface.
  2. Press the “On/Off/Tare” button and hold it until the value of 0.000kg is displayed.
  3. Place the load on the scale; the weight value will be shown on the display.

3.2 Hold Function
The hold function keeps the displayed data from disappearing, which is convenient for recording. Load the weight up and after the weight value stabilizes, the weight value will flash for 3 seconds and then automatically lock (locked after the second flash). 33 Mode The scale has five weighing units, namely kg/g/lb/ozilbioz, as shown below

MUNBYN IPS01 Digital Shipping Postal Scale - fig1

3.4 Tare
When using a container to weigh something, use this function to subtract the weight of the container as follows.

  1. Place an empty container on the scale.
    MUNBYN IPS01 Digital Shipping Postal Scale - fig4

  2. Short press the “On/Off/Tare” button to subtract the tare and the value will be cleared to 0.000kg.
    MUNBYN IPS01 Digital Shipping Postal Scale - fig5

  3. Put the items to be weighed in the container.

3.5 PCS
When you need to determine the number of multiple identical parts, you can use the “PCS” function.

  1. In the weighing state, long-press the “PCS” button to enter the sample number selection.

  2. Press the “MODE” button to switch between 25/50/75/100, sample sizes and load the sample after selection.
    MUNBYN IPS01 Digital Shipping Postal Scale - fig2

  3. Short press the “PCS” button to confirm the number of samples, then “PASS” will appear on the screen.
    MUNBYN IPS01 Digital Shipping Postal Scale - fig8

  4. Place an unknown number of items to measure on the scale, the device will count them and display the quantity.

3.6 Calibration
Weighing errors will occur after the postal scale has been used frequently for a long time and calibration is required when the error exceeds the requirements.

  1. In the weighing state, long-press the “MODE” button to display the calibration units (kg/lb). Such as:
    MUNBYN IPS01 Digital Shipping Postal Scale - fig6

  2. Short press the “On/Off/Tare” button to switch calibration units, then short press the “MODE” button to confirm.

  3. Short press the “On/Off/Tare” button to set the tens place, such as 12kg, 22kg, etc.

  4. Short press the “PCS” button to set the ones in place, such as 3kg, 4kg, Skg, etc. The setting method for English units is similar.

  5. After setting the calibration weight, press the “MODE” button to confirm the display of “CAL” and then the flashing calibration weight will be displayed.
    MUNBYN IPS01 Digital Shipping Postal Scale - fig7

  6. Load the weight. After the weight stabilizes, the actual weight will be displayed after “PASS” is displayed.
    MUNBYN IPS01 Digital Shipping Postal Scale - fig3

3.7 Custom shutdown time
When powered by battery, you can customize the shutdown time per the following steps:

  1.  In the zero states, long-press the “On/Off/Tare” button to enter the shutdown time selection.
  2. Press “On/Off/Tare” button to switch between “1” (minutes) , “3” (Minutes), “5” (minutes) and “-“(No shutdown).
  3. press the “MODE” button to confirm.
    Note: When using the DC power supply, the scale does not automatically shut down.

3.8 Error messages
Overload:
MUNBYN IPS01 Digital Shipping Postal Scale - fig9Low battery:
MUNBYN IPS01 Digital Shipping Postal Scale - fig10

4. FAQ

Ql: What is the calibration interval? Al: 2-55Ib/2-22kg.
Q2: How to exit function mode?
A2: To exit the function mode, press the”On/Off/Tare” button until the screen turns oft
Q3: How long will the unit run on battery power?
A3: It is related to specific battery capacity. Theoretically,
a 175mAh AAA alkaline battery can be used continuously for 6 hours.
Q4: If the AC adapter and batteries are installed at the same time, which one will be used?
A4: When the adapter is connected, it will automatically disconnect the battery.
Q5: Waterproof performance
AS: The scale is splash-proof, but full immersion will damage the equipment.

SUPPORT

|
---|---
https://wa.me/qr/5R2RRPLNUBYNH1| https://www.facebook.com/munbyn/

Need Tech Support? contact us by:
Mail: support@munbyn.com
Whatsapp: +8617817881067
Skype: Munn
Support time: Monday to Frida, 24 hours.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals