ATLAS ATR2EHMFB IP66 Reader
Introduction
The ATR2EHMFB reader is designed with a thin profile and modern appearance. It can read 125KHz EM & HID, and 13.56MHz Cards/Fobs. The reader is IP66 so can be installed indoors or outdoors.
Specification
Model | ATR2EHMFB |
---|---|
Operation Voltage | 9 – 24V DC |
Standby Current | ≤25mA |
Frequency | 125KHz and 13.56MHz |
Card Type | 125KHz – EM & HID Card/Fobs |
13.56 MHZ – Mifare Card (ISO 14443A Compatible)
Read Range| Up to 7cm
Output Format
| EM Card: Weigand 26 bits Mifare Card: Weigand 34 bits
HID Card: Weigand 26 – 37 bits (Auto)
Operation Temperature| -40°C ~ 60°C
Operating Humidity| 10% to 95% RH
Colour| Black
Index of Protection| IP66
Dimension (L x W x H)| L120 x W48 x H20mm
Net Weight| 120g
Shipment Weight| 170g
Installation
- Drill 2 holes (A,C) on the wall for the screws and one hole for the cable.
- Use the wall fixing plugs in hols (A,C)
- Fix the back cover on the wall with 2 screws.
- Thread the cable through the cable hole (B)
- Attach the unit to the back cover.
Wiring
Colour | Function | Notes |
---|---|---|
Red | Power | +DC (9 – 24V DC) |
Black | GND | Ground |
Green | D0 | Data 0 |
White | D1 | Data 1 |
Brown | LED | Green LED Light Control |
Yellow | Buzzer | Buzzer Control |
(Note: Brown and Yellow wires are optional connections)
Functions Table Sheet
Read Card| The LED light will turn Green, the buzzer sounds beep and the
reader outputs the Weigand signal.
---|---
External LED Control| When the input voltage for the LED is low, the LED will
turn Green.
External
Buzzer Control
| When the input voltage for the Buzzer is low, the Buzzer will
sound.
Weigand Data Output| EM Card output Weigand 26 bits, Mifare Card output Weigand 34 bits, HID card output Weigand 26 – 37 bits automatically.
Data Signal
Description | Reader Typical Time |
---|---|
Pulse Width Time | 42 µS |
Pulse Interval Time | 2 mS |
The table below shows the wave form of pulse width time (the duration of a pulse) and pulse interval time (the time between pulses) of the Weigand data output from the readers. (Example 1010).
Packing List
Name | Quantity |
---|---|
Reader | 1 |
Manual | 1 |
Screw Driver | 1 |
Wall fixing Plugs | 2 |
Self-Tapping Screws | 2 |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>