Atlas Copco A2920 Klucz Udarowy Sklep Marat Instructions
- June 1, 2024
- Atlas Copco
Table of Contents
Atlas Copco A2920 Klucz Udarowy Sklep Marat
Specifications
Specification | IWD 50/105/125/250 | IWD 500/2665/5000 |
---|---|---|
Collector volume | IWD 50: 0.06 ft³ |
IWD 105: 0.08 ft³
IWD 125: 0.09 ft³
IWD 250: 0.11 ft³| IWD 500: 0.22 ft³
IWD 2665: 0.5 ft³
IWD 5000: 1.5 ft³
Condensate inlet| IWD 50: 1x G3/4″ M
IWD 105: 1x G1/2″ F
IWD 125: 1x G1/2″ F + 1x G3/4″ M
IWD 250: G1/2″ F| IWD 500: 1x G1/2″ F + 1x G3/4″ M
IWD 2665: 1x G3/4″ M
IWD 5000: 2x G1/2″ F + 1x G3/4″ M
Condensate outlet (hose)| 12 mm / 0.47 inch
Supply voltage| V See data plate, ± 10 %
Frequency| 50-60 Hz
Isolation class| IP 65
Maximum power consumption| 10 VA
Alarm contact| Contact NC/NO: 240V Ac max – 1A / 30V Dc max – 1A
Electric connection| EN 175301-803 Type B
Alarm connection| M12 Code A 4 Poles
Fuse| 1 A
Maximum rise of outlet line| 5 m / 16.4 ft
FAQ
What is the maximum working pressure for the devices?
The maximum working pressure for IWD 50, 105, 125, and 250 is 16 bar or 232 psi. For IWD 500, 2665, and 5000, the specifications should be referred to in the instruction book for accurate data.
Are the electronic water drains suitable for all types of condensate?
Yes, the electronic water drains are suitable for all condensates.
What are the nominal flow rates for the IWD 50, 105, 125, and 250?
The nominal flow rates are 50 l s 106 cfm 105 l s 222 cfm 125 l s 265 cfm and 250 l s 530 cfm respectively.
What material is used for the condensate collector?
The condensate collector material is aluminium for all listed models.
What is the alarm contact specification?
The alarm contact is rated for Contact NC NO: 240V Ac max - 1A 30V Dc max - 1A.
Technical data
Reference conditions and limitations
Reference conditions
Reference ambient temperature | oc | 20 |
---|---|---|
Reference ambient temperature | OF | 68 |
Reference relative humidity | % | 60 |
Limits
Minimum temperature | oc | 1 |
---|---|---|
Minimum temperature | OF | 33.8 |
Maximum temperature | oc | 60 |
Maximum temperature | OF | 140 |
Minimum working pressure | bar | 0.2 |
Minimum working pressure | psi | 3 |
Maximum working pressure | bar | 16 |
Maximum working pressure | psi | 232 |
Electronic water drain data
IWD50 | IWD 105 | IWD 125 | IWD 250 | |
---|---|---|---|---|
Nominal flow | 1/s | 50 | 105 | 125 |
cfm | 106 | 222 | 265 | 530 |
Nominal drain | 1/h | 2 | 3 | 5 |
cfh | 0.07 | 0.12 | 0.18 | 0.35 |
Maximum drain | 1/h | 5 | 10 | 15 |
cfh | 0.18 | 0.35 | 0.53 | 0.71 |
Maximum compressor capacity when used as compressor drain | 1/s | 50 | 105 | 125 |
250
cfm| 106| 222| 265| 530
Maximum dryer capacity when used as dryer drain| 1/s| 100| 210| 250| 500
cfm| 212| 445| 530| 1059
Maximum filter capacity when used as filter drain| 1/s| 500| 1050| 1250| 2500
cfm| 1059| 2225| 2649| 5297
Weight| kg| 0.4| 0.5| 0.6| 0.7
lb| 0.88| 1.10| 1.32| 1.54
Type of condensate| | Suitable for all condensate
Collector material| | Aluminium
| IWD50| IWD 105| IWD 125| IWD 250
---|---|---|---|---
Collector volume| I| 0.06| 0.08| 0.09| 0.11
ft3| 0.002| 0.003| 0.003| 0.004
Condensate inlet| G-NPT| 1x G3/4″ M| 1x G1/2″ F| 1x G1/2″ F + 1x G3/4″ M –
G1/2″ F
Condensate outlet (hose)| mm| 12
inch| 0.47
Supply voltage| V| See data plate,± 10 %
Frequency| Hz| 50-60
Isolation class| | IP 65
Maximum power consumption| VA| 10
Alarm contact| | No alarm| Contact NC/NO: 240V Ac max – 1A / 30V De max – 1A
Electric connection| | EN 175301-803 Type B
Alarm connection| | –| M12 Code A 4 Poles
Fuse| A| 1
Maximum rise of outlet line| m| 5
ft| 16.4
| IWD 500| IWD 2665| IWD 5000
---|---|---|---
Nominal flow| 1/s| 500| 2667| 5000
cfm| 1059| 5650| 10594
Nominal drain| 1/h| 20| 90| 200
cfh| 0.71| 3.18| 7.06
Maximum drain| 1/h| 35| 150| 350
cfh| 1.24| 5.30| 12.36
Maximum compressor capacity when used as compressor drain| 1/s| 500| 2667|
5000
cfm| 1059| 5650| 10594
Maximum dryer capacity when used as dryer drain| 1/s| 1000| 5333| 10000
cfm| 2119| 11301| 21189
Maximum filter capacity when used as filter drain| 1/s| 5000| 26667| 50000
cfm| 10594| 56503| 105944
Weight| kg| 1.2| 1.8| 3.45
lb| 2.65| 3.97| 7.61
Type of condensate| | Suitable for all condensate
Collector material| | Aluminium
Collector volume| I| 0.22| 0.5| 1.5
ft3| 0.008| 0.018| 0.053
Condensate inlet| G-NPT| 1x G1/2″ F + 1x G3/4″ M – G1/2″ F| 2x G1/2″ F +
1x G3/4″ F
Condensate outlet (hose)| mm| 12
inch| 0.47
Supply voltage| V| See data plate, ± 10 %
Frequency| Hz| 50-60
Isolation class| | IP 65
| IWD 500 IIWD 2665 IIWD 5000
---|---
Maximum power consumption| VA| 10
Alarm contact| | Contact NC/NO: 240V Ac max – 1A / 30V De
max – 1A
Electric connection| | EN 175301-803 Type B
Alarm connection| | M12 Code A 4 Poles
Fuse| A| 1
Maximum rise of outlet line| m| 5
ft| 16.4
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>