Danfoss ECtemp 532 Electronic Thermostat Installation Guide

June 5, 2024
Danfoss

ENGINEERING
TOMORROW
Installation Guide
Danfoss ECtemp 532
Electronic Thermostat

Introduction

ECtemp 532 is an electronic thermostat provided with a 2-pole switch, a room sensor to control the room temperature, and an additional floor sensor to limit the maximum
floor temperature. It can be either flush-mounted or surface-mounted.
The thermostat has a button for adjusting the temperature setting with a scale from 5-35°C. Furthermore, it has a LED indicator showing standby periods (green light) and
heating periods (red light).
More information on this product can also be found at:ectemp.danfoss.com

1.1 Technical Specifications

Operation voltage|

220-240 V~, 50 Hz

---|---
Standby power consumption| Max 0.25 W
Relay: Resistive load Inductive load| Max 15 A / 3450 W @ 230 V
cos φ= 0.3 max 1A
Sensing units| NTC 15kOhm at 25°C
Sensing values:
0 °C
25 °C
50 °C|
42 kOhm
15 kOhm
6 kOhm
Hysteresis| ± 0.4 °C
Ambient temperature| -10 to +30 °C
Frost protection temperature| 5 °C –
**** Temperature range| 5-35°C room temperature 20-50°C floor temperature limiter – default 35°C
Cable specification max| 1×4 mm² or 2×2,5 mm²
Ball pressure temperature| 75 °C
Pollution degree| 2 (domestic use)

Danfoss ECtemp 532

Type 1C
Storage temperature -20 to +65 °C
IP class 31
Protection class Class II – ****
Dimensions 85 x 85 x 36 mm
Weight 90 g

The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use”:

  • EN/IEC 60730-1 (general)
  • EN/IEC 60730-2-9 (thermostat)

1.2 Safety Instructions
Make sure the mains supply to the thermostat is turned off before installation.
IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor, and never set the maximum floor temperature to more than 35°C.

Please also note the following:

  • The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.
  • The thermostat must be connected to a power supply via an all-pole disconnection switch.
  • The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended.
  • Always connect the thermostat to the continuous power supply.
  • Do not expose the thermostat to moisture, water, dust, and excessive heat.

Mounting Instructions

Please observe the following placement guidelines:

| Place the thermostat at a suitable height on the wall (typically 80-170cm.).
---|---
| In wet rooms, always place the thermostat according to local regulations on IP classes.
| Do not place the thermostat on the inner side of an exterior wall.
| Always install the thermostat at least 50 cm. from windows and doors.
| Do not place the thermostat in a way that it will be exposed to direct sunlight.
| Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and
mandatory under wooden floors to reduce the risk of over-heating the floor.

  • Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings.
  • Equally distant and >2cm from two heating cables.
  • The conduit should be flush with the floor surface -countersink the conduit if necessary.
  • Route the conduit to the connection box.
  • The bending radius of the conduit must be min 50mm.

Follow the steps below to mount the thermostat:

  1. Open the thermostat:

    • Press the release tab in the bottom of the thermostat using a flat object.
    • Carefully detach the front cover.
    • Carefully detach the frame.

  2. Connect the thermostat according to the connection diagram.
    The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
    Note: Always install the floor sensor in a conduit in the floor.

  3. Set the maximum floor temperature between 20° and 50°C by turning the screw with temperature indications in the upper left corner.

  4. Mount and reassemble the thermostat:
    • Fasten the thermostat to a flush-mounting box or a surface-mounting box by driving the screws through the holes in each side of the thermostat.
    • Install the frame and front cover in the reverse order of disassembly.

  5. Turn on the power supply.

Settings

How to change the minimum and maximum floor temperatures

  1. Remove the adjustment button.
  2. Move the pins to the desired positions.
  3. Put the adjustment button back in place.

Note: Please be aware of the following:

  • The floor temperature is measured where the floor sensor is placed.
  • The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top.
  • Floor manufacturers often specify the max temperature on the top surface of the floor (usually 27-28˚C).
  • By default, the maximum floor temperature is set to 35°C.
  • Always use a floor sensor or a room + floor sensor combination to control floor heating. Without a floor sensor, the temperature control may be less accurate and you risk overheating the floor.

Thermal resistance [m²K/W]| Examples of flooring| Details| Approximate setting for 25 °C on the top surface of the floor
---|---|---|---
0,05| 8 mm HDF-based laminate| > 800 kg/m³| 28 °C
0,10| 14 mm beech parquet| 650 – 800 kg/m³| 31 °C
0,13| 22 mm solid oak plank| > 800 kg/m³| 32 °C
< 0,17| Max. carpet thickness suitable for floor heating| acc. to EN/IEC 1307| 34 °C
0,18| 22 mm solid fir planks| 450 – 650 kg/m³| 35 °C

Warranty

A 2-year product warranty is valid for:

  • thermostats: ECtemp 532.
    Should you, against all expectations, experience a problem with your Danfoss product, you will find that Danfoss offers a Danfoss warranty valid from the date of purchase on the following conditions: During the warranty period Danfoss shall offer a new comparable product or repair the product if the product is found to be faulty by reason of defective design, materials or workmanship. The repair or replacement.
    The decision to either repair or replace will be solely at the discretion of Danfoss. Danfoss shall not be liable for any consequential or incidental damages including, but not limited to, damages to property or extra utility expenses. No extension of the warranty period following repairs undertaken is granted.
    The warranty shall be valid only if the WARRANTY CERTIFICATE is completed correctly and in accordance with the instructions, the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided. Please note that the WARRANTY CERTIFICATE must be filled in, stamped, and signed by the authorized installer performing the installation (Installation date must be indicated). After the installation is performed, store and keep the WARRANTY CERTIFICATE and purchase documents (invoice, receipt, or similar) during the whole warranty period.
    Danfoss warranty shall not cover any damage caused by incorrect conditions of use, incorrect installation, or if an installation has been carried out by non-authorized electricians. All work will be invoiced in full if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above. The Danfoss warranty shall not extend to products that have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers.
    The warranty explicitly excludes all claims exceeding the above conditions.
    For full warranty text please use QR code

https://assets.danfoss.com/documents/latest/186757/BD379947576613en-010103.pdf

WARRANTY CERTIFICATE

The Danfoss warranty is granted to:
Address| Stamp
Purchase date
Serial number of the product
Product| Art. No.
*Connected output [W]
Installation Date & Signature| Connection Date & Signature

*Not mandatory

Disposal Instruction

Danfoss A/S
Nordborgvej 81
6430 Nordborg, Syddanmark
Denmark

Danfoss A/S
Climate Solutions • danfoss.com • +45 7488 2222
Any Information, including, but not limited to information on selection of product its application or use, product design, weight, dimensions, capacity, or any other technical data in product manuals, catalogs descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogs, brochures, videos, and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.

ECtemp 532 ELKO
088L0035
Thermostat
Floor/Room Sensor
220-240V~
50-60Hz~
+5 to +35°C
15A/3450W@230V~ IP 31

| http://SCN.BY/9T7N6HN0RDQUMD
---|---

**

08091241 & AQ059186456572en-010102
Produced by Danfoss © 07/2022**