MALMBERGS Acis LED Wall-Ceiling Luminaire Instruction Manual

June 3, 2024
MALMBERGS

Acis LED Wall-Ceiling Luminaire
Instruction Manual

MALMBERGS Acis LED Wall-Ceiling Luminaire

Acis LED Wall-Ceiling Luminaire

Wall/Ceiling Luminaire with HF Sensor and Orientation Light
IMPORTANT: Please read the instruction manual carefully prior to installation and keep it for future reference. MALMBERGS Acis LED Wall-
Ceiling Luminaire - icon

IMPORTANT

  1. This product should be installed by a registered electrician in accordance with local standards and electrical regulations.
  2. Ensure the mains supply is cut off before installation.
  3. Check the unit label for the correct supply voltage and frequency.
  4. Note: When connecting to the power, the luminaire will perform a self-test during approx. 20 seconds to check that the sensor is connected. During this period, the daylight sensor may not work properly to check the ambient natural light.

NOTE

  1. The diffuser must not be covered.
  2. The rating label must not be removed from the lamp.

DESCRIPTION

The fitting is equipped with an LED module. Complete with the driver.

TECHNICAL SPECIFICATIONS

Art.no: 99 751 99
Wattage: 18W LED
Lumen: 1800lm
Output LED current: 500mA, the default setting
Dims ØxH: 275×78 mm
Mounting: Wall or ceiling. Note: The terminal block is located under the

diffuser. Loosen the screws (4 pcs) and remove the diffuser. Connect the luminaire to the mains.
Detection area:| Ceiling mounting up to 6 meters
Connection:| To terminal block 3×2.5 mm²
Protection class:| IP65

Note: The LED current is factory set and must not be changed.MALMBERGS
Acis LED Wall-Ceiling Luminaire - 1

FEATURES

  1. Three levels of light: 100%, orientation light (10%, 20%, 30%, 50% optional), and OFF.
  2. Two periods of selectable waiting time: motion hold time after the person has left the detection area and standby period with orientation light.
  3. Selectable daylight threshold.
  4. Selectable detection area.

MALMBERGS Acis LED Wall-Ceiling Luminaire - 2

With sufficient natural light, the light does not switch on when presence is detected. See point 3 above.| With insufficient natural light, the light switches automatically when a person enters the room.
MALMBERGS Acis LED Wall-Ceiling Luminaire - 3
After the people have left, the light dims to 10%, 20%, 30%, and 50% (selectable) stand-by level after the hold time.| The light switches off automatically after the stand-by period has elapsed.

SENSOR DIMMING SETTING OPTIONS
Detection area:

The detection area can be reduced by selecting the combination of the DIP switches to fit precisely for each specific application.
I – 100%
II – 75%
III – 50%
IV – Sensor off

Hold Time Hold-time means the time period to keep the lamp on 100% after the people have left the detection area.

I – 5 s
II – 30 s
III – 1 minutes
IV – 5 minutes
V – 10 minutes
VI – 20 minutes
VII – 30 minutes

Daylight Sensor: The daylight threshold can be set on DIP switches, to fit a particular application.

I – Disabled
II – 50 lux
III – 10 lux
IV – 2 lux

Stand-by period (orientation light):MALMBERGS Acis LED Wall-Ceiling
Luminaire - 9

This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people.

I – On/off, no orientation light
II – 10 s
III – 1 minute
IV – 5 minutes
V – 10 minutes
VI – 30 minutes
VII – 1 hour
VIII – Always orientation light
Orientation light is constantly on if the light in the room is under the set Lux value and when there is no activity in the detection area. When there is an activity the luminaires
are lit to 100%. The orientation light on/off is controlled automatically depending on the light in the room. See the example below.

MALMBERGS Acis LED Wall-Ceiling Luminaire - 11

The light switches on at 100% when motion is detected.| The light dims to the orientation light level after the set hold time (no motion).| The orientation light is on during the night.
MALMBERGS Acis LED Wall-Ceiling Luminaire - 12
When the light level exceeds the set Lux value the light switches off.| When the light in the room is under the set Lux level, the orientation light switches on again.

Stand-by dimming level:MALMBERGS Acis LED Wall-Ceiling Luminaire -
13 This is the dimmed low-light output level you would like to have after the hold time in the absence of people.
I – 10%
II – 20%
III – 30%
IV – 50%

Malmbergs Elektriska AB, PO
Box 144, SE-692 23 Kumla, SWEDEN
Phone: +46 19 58 77 00
Fax: +46 19 57 11 77
info@malmbergs.com
www.malmbergs.com

Read these instructions before starting the installation and hand it over to the user when finished.

safety instructions

  1.  the luminaire must be installed by a qualified electrician and according to existing regulations.
  2. the manufacturer is not liable for damage or malfunction caused by improper handling of the luminaire.
  3. the luminaire must not be modified.
  4. Please acknowledge that the light from LeD is very bright, please do not look directly into the LeD light.
  5. You may replace electrical accessories such as cables, lamp holders, and plugs of movable appliances, and also wall sockets and switches in fixed installations if you know how to. incorrect installation may result in fire and/or serious personal injury.
  6. CAUTION! turn off the power, remove the fuse from the distribution box or set the McB to the “OFF” position, before starting any installation work.
  7. Make sure that moisture does not come in contact with any live parts.
  8. Plugs and terminals must be free from tension and torsion forces.
  9. NOTE! The light source cannot be replaced. If the LED diode(s) fails, the whole luminaire must be replaced. Installation

Make sure that electrical wires are not damaged during installation.
Electrical safety classification: Class I **this luminaire has to be connected to the earth with green/yellow wire.
Electrical safety classification: Class IIIcon this luminaire is double insulated and must not be connected to the earth terminal.
Designation of terminals: L – live, n – neutral, **– earth. the specified voltage (230-240V/50hz) must not be exceeded.

SYMBOL FOr SeArAte collection

this symbol indicates that this product is to be collected separately.
the following apply:

  • this product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste.
  • For more information, contact the local authorities in charge of waste management.

By providing these materials for recycling, you contribute substantially to protecting the environment.

Malmbergs Elektriska AB (publ)
PO Box 144, Se-692 23
Kumla, SweDen
Phone: +46 (0)19 58 77 00
Fax: +46 (0)19 57 11 77
info@malmbergs.com
www.malmbergs.com

Acis Sensor Dim LED

MALMBERGS Acis LED Wall-Ceiling Luminaire - 15

Instruction for Light Source Disassembly

MALMBERGS Acis LED Wall-Ceiling Luminaire - 16NOTE! The light source is non-user replaceable and must only be replaced by the manufacturer, its service agent or a similarly qualified person. This product contains a light source of energy efficiency class D.

MALMBERGS Acis LED Wall-Ceiling Luminaire - 17 Malmbergs Elektriska AB, PO Box 144, SE-692 23
Kumla, SWEDEN Phone: +46 (0)19 58 77 00
info@malmbergs.com
www.malmbergs.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals