MALMBERGS 3145217 Last Balancing Evon Last Balance Instruction Manual
- June 1, 2024
- MALMBERGS
Table of Contents
MALMBERGS 3145217 Last Balancing Evon Last Balance
NOTE: Please read through the manual carefully prior to installation and keep it for future reference.
CONNECTION
- Find the two blue receptions on the PCBA board as picture 1 and 2 show, and distinguish A port and B port.
- Find A port and B port on the electric meter (see picture 3).
- Connect the electric meter to the PCBA.
- Connect the main breaker and meter (see picture 4).
- A. Find three input ports labeled L1, L2, L3 and N on the electric meter.
- B. Connect the four input ports to home electric meter box.
PARAMETER CONFIGURATION
A. APP Configuration (see picture A)
- Open “Chargeln” APP, choose “Smart Meter” solution in the “Load Balance” tab.
- Input the maximum household load current capacity, you can set the value from 10A to 80A.
- Click “Submit” to enable this feature.
B. AP Mode Configuration (see picture B 1-3)
Note: Please refer to the AP Manual to enter the configuration page first.
- Please select the load balance option under the Charger Setup block.
- Then select Smart Meter to “Yes” and CT option to “No”, then click “Next”.
- Enable the Load Balance function, you can set the Maximum Available Current from 10A to 80A, then please click “Confirm”.
TECHNICAL SPECIFICATIONS
Project | Performance parameter |
---|---|
Specification | 3 phase 3 wires |
“Reference & voltage | 3x100V, |
3x400V
| 3×57.7/100V
3×220/400V
Voltage| Voltage range| 3x100V-
3x450V
| 3×57.7/100V-
3×260/450V
| Consumption| <10VA (Single phase)
| Impedance| >2MO
| Accuracy class| Error±0.2%
current| Input current| 3×1 (6)A, 3×10(80)A
Consumption| <1VA Single phase rated current
Accuracy class| Error±0.2%
Power| Active, reactive, apparent Power error+0.5 %
Frequency| 45~65Hz, Error±0.2%
Energy
| Active energy (Accuracy class: 0.5); reactive energy (Accuracy class 2)
Clock| ,; 0.5s/d
Energy pulse output| 1 active photocopier output
Width of pulse| 80±20ms
Pulse constant
| 400imp/kWh,10000imp/kWh
(Correspond with the basic current)
Interface and protocol| RS485: Modbus RTU
Range of communication address| Modbus RTU:1 ~ 254
Baud rate| 1200bps-38400bps
Working temp.| -25°C ~ +55°C
Relative humidity| ,; 95% (No condensation)
STANDARDS AND DECLARATION
STANDARDS
- EN 61326-1:2013, EN 61000-3-2:2014,
- EN 61000-3-3:2013, EN 61010-1:2010,
- EN 62321-5:2014, EN 62321-4:2014/A1:2017,
- EN 62321-7-1:2015, EN 62321-7-2:2017,
- EN 62321-6:2015, EN 62321-8:2017
DECLARATION OF CONFORMITY
We hereby certify that the device satisfies the provisions for CE marking in accordance with the EU directives (LV Directive 2014/35/EU, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU, (EU) 2015/863) as described in this manual.
For and on behalf of:
- Malmbergs Elektriska AB, Sweden.
- Mr. Anders Folke / Product Manager
- Date: 10/01/2023