MALMBERGS 3145217 Last Balancing Evon Last Balance Instruction Manual

June 1, 2024
MALMBERGS

MALMBERGS 3145217 Last Balancing Evon Last Balance

MALMBERGS-3145217-Last-Balancing-Evon-Last-Balance-
product

NOTE:  Please read through the manual carefully prior to installation and keep it for future reference.

CONNECTION

MALMBERGS-3145217-Last-Balancing-Evon-Last-Balance-
fig-1 MALMBERGS-3145217-Last-Balancing-
Evon-Last-Balance-fig-2

  1. Find the two blue receptions on the PCBA board as picture 1 and 2 show, and distinguish A port and B port.
  2. Find A port and B port on the electric meter (see picture 3).
  3. Connect the electric meter to the PCBA.
  4. Connect the main breaker and meter (see picture 4).
    • A. Find three input ports labeled L1, L2, L3 and N on the electric meter.
    • B. Connect the four input ports to home electric meter box.

PARAMETER CONFIGURATION

A. APP Configuration (see picture A)

MALMBERGS-3145217-Last-Balancing-Evon-Last-Balance-
fig-3

  1. Open “Chargeln” APP, choose “Smart Meter” solution in the “Load Balance” tab.
  2. Input the maximum household load current capacity, you can set the value from 10A to 80A.
  3. Click “Submit” to enable this feature.

B. AP Mode Configuration (see picture B 1-3)

Note: Please refer to the AP Manual to enter the configuration page first.

MALMBERGS-3145217-Last-Balancing-Evon-Last-Balance-
fig-4

  1. Please select the load balance option under the Charger Setup block.
  2. Then select Smart Meter to “Yes” and CT option to “No”, then click “Next”.
  3. Enable the Load Balance function, you can set the Maximum Available Current from 10A to 80A, then please click “Confirm”.

TECHNICAL SPECIFICATIONS

Project Performance parameter
Specification 3 phase 3 wires
“Reference & voltage 3x100V,

3x400V

| 3×57.7/100V

3×220/400V

Voltage| Voltage range| 3x100V-

3x450V

| 3×57.7/100V-

3×260/450V

 | Consumption| <10VA (Single phase)
 | Impedance| >2MO
| Accuracy class| Error±0.2%
current| Input current| 3×1 (6)A, 3×10(80)A
Consumption| <1VA Single phase rated current
Accuracy class| Error±0.2%
Power| Active, reactive, apparent Power error+0.5 %
Frequency| 45~65Hz, Error±0.2%


Energy

| Active energy (Accuracy class: 0.5); reactive energy (Accuracy class 2)
Clock| ,; 0.5s/d
Energy pulse output| 1 active photocopier output
Width of pulse| 80±20ms


Pulse constant

| 400imp/kWh,10000imp/kWh

(Correspond with the basic current)

Interface and protocol| RS485: Modbus RTU
Range of communication address| Modbus RTU:1 ~ 254
Baud rate| 1200bps-38400bps
Working temp.| -25°C ~ +55°C
Relative humidity| ,; 95% (No condensation)

STANDARDS AND DECLARATION

STANDARDS

  • EN 61326-1:2013, EN 61000-3-2:2014,
  • EN 61000-3-3:2013, EN 61010-1:2010,
  • EN 62321-5:2014, EN 62321-4:2014/A1:2017,
  • EN 62321-7-1:2015, EN 62321-7-2:2017,
  • EN 62321-6:2015, EN 62321-8:2017

DECLARATION OF CONFORMITY

We hereby certify that the device satisfies the provisions for CE marking in accordance with the EU directives (LV Directive 2014/35/EU, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU, (EU) 2015/863) as described in this manual.

For and on behalf of:

  • Malmbergs Elektriska AB, Sweden.
  • Mr. Anders Folke / Product Manager
  • Date: 10/01/2023

CONTACT

Malmbergs Elektriska AB (publ)

Read User Manual Online (PDF format)