99 720 13-15 Malmbergs Breda LED Instruction Manual

June 9, 2024
MALMBERGS

Breda LeD
Instruction Manual99 720 13-15 Malmbergs Breda LED
-

99 720 13-15 Malmbergs Breda LED

IMPORTANT: Please read the instruction manual carefully prior to installation and keep it for future reference.

99 720 13-15 Malmbergs Breda LED - fig 1

Ceiling Luminaire with HF Sensor

Note

  • the diffuser must not be covered.
  • the rating label must not be removed from the lamp.

DESCRIPTION
The fitting is equipped with LeD module. Complete with driver.
MOUNTING
Ceiling mounting.
Note: the terminal block is located under the diffuser. press on the side of the diffuser to loosen it from the luminaire. Connect the luminaire to the mains.
PROUCT DESCRIPTION(Fig. A)

  1. Load
  2. power supply
  3. Daylight sensor
  4. Daylight threshold
  5. Hold time
  6. Detection area

The sensor is an active motion detector; it emits a high-frequency electromagnetic wave, 5.8gHz, and receives its echo. the sensor detects the change in echo from even the slightest movement in its detection zone.
A microprocessor then triggers the switch light oN command. Detection is possible through doors, panes of glass or thin walls.
Persons or objects moving towards the sensor are detected best.
INSTALLATION AND WIRNING (Fig. B)
Ensure that the electricity supply is switched off completely before installing or servicing this product.
The sensor works with a main voltage of 220-240V (+/-10%) 50/60Hz.

  1. Driver
  2. L’ (output, 230V AC)
  3. N (neutral / 230V AC)
  4. L (phase / 230V AC)

SETTING INSTRUCTIONS FOR THE SENSORE

Detection range:
This determines the effective range of the motion detector and is set by Dip switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range.

The following settings are available:
i – maximum range 100%
ii – range 75%
iii – range 50%
iV – range 10%

Hold Time:
this determines the time the fitting remains at 100% level on motion detection and is set with Dip switches at the sensor itself, refer to figure.
the walk test setting is useful when installing the fitting to establish correct operation and range.

the following settings are available:
i – Walk test mode 5 s
ii – 90 s
iii – 5 minutes
iV – 15 minutes

Daylight Threshold:
this setting holds off the 100% light output should there be sufficient daylight and is set using Dip switches at the sensor, refer to figure.

the following settings are available:
i – *daylight, light sensor disabled
ii – 50 lux
iii – 10 lux
iV – 2 lux

  • in daylight setting the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright daylight.

TECHNICAL SPECIFICATIONS

Luminaire

Art. no| 9972013| 9972014| 9972015
Wattage| 11/13/16/20W LED| 23/29/35/40W LED| 26/33/40/47W LED
Lumen| 1400/1600/
2000/2500 Im| 3200/4000/
4900/5600 Im| 3600/4600/
5600/6500 Im
Dims WxHxD (mm)| 595x52x155| 1195x52x155| 1495x52x155
Connection| To terminal block 5×2.5 mm
IP rating| IP44 (Ceiling Mounted)
IP40 (Wall Mounted/Suspension/Wire Suspension)
Sensor

Type of sensor| 5.8GHz Microwave Motion Sensor
Operating voltage| 220-240V- 50Hz
Transmission power| <0.3 mW
Detection angle| 150°
Power consumption| Approx. 0.5W
Detecting range| 4-5 m (radius), at mounting height 3 m
Mounting height| <6 m
Time setting| 5 sec. – 15 min.
Light control| 2-50Lux, inactive

TROUBLESHOOTING

Malfunction Possible Cause Remedy

The load will not work despite
movement| Incorrect light-control setting selected| Adjust setting
Mains switch OFF| Switch ON
Incorrect setting of detection area| Increase the detection area
The load is always on| Continuous movement in the detec-tion area because the detection area is too large| Decrease the detection area
The sensor is not set correctly| Reset the sensor

99 720 13-15 Malmbergs Breda LED - remaining afte

L80: 80% of lumen output is remaining after 100000 hrs.
B10: 90% of the luminaires will meet the declared L value.

Read these instructions before starting the installation and hand it over to the user when finished.

SAEFTY INSTRUCTIONS

  1. the luminaire must be installed by a qualified electrician and according to existing regulations.
  2. the manufacturer is not liable for damage or malfunction caused by improper handling of the luminaire.
  3. the luminaire must not be modified.
  4. Please acknowledge that light from LeD is very bright, please do not look directly into the LeD light.
  5. You may replace electrical accessories such as cables, lamp holders and plugs of movable appliances, and also wall sockets and switches in fixed installations, if you know how to. incorrect installation may result in fire and/or serious personal injury.
  6. CAUTION! turn off the power, remove the fuse from the distribution box or set the McB to the “OFF” position, before starting any installation work.
  7. Make sure that moisture does not come in contact with any live parts.
  8. Plugs and terminals must be free from tension and torsion forces.
  9. NOTE! The light source is non-user replaceable and must only be replaced by the manufacturer, its service agent or a similar qualified person.

INSTALLATION

Make sure that electrical wires are not damaged during installation.
Electrical safety classification: Class I this luminaire has to be connected to earth with the green/yellow wire.
Electrical safety classification: Class II Icon this luminaire is double insulated and must not be connected to earth terminal.
Designation of terminals: L – live, n – neutral, –
earth. the specified voltage (230-240V/50hz) must not be exceeded.

SYMBOL FOR SEPARATE COLLECTION

This symbol indicates that this product is to be collected separately.
the following apply:

  • this product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste.
  • For more information, contact the local authorities in charge of waste management.
    By providing these materials for recycling, you contribute substan-tially to protect the environment.

Breda LED

99 720 13-15 Malmbergs Breda LED - Breda LED

Operation and connection

99 720 13-15 Malmbergs Breda LED - Operation and
connection

L80: 80% of lumen output is remaining after 100000 hrs. B10: 90% of the luminaires will meet the declared L value.

99 720 13-15 Malmbergs Breda LED - ICON 0

99 720 13-15 Malmbergs Breda LED - fig 299 720
13-15 Malmbergs Breda LED - fig 3The different lumen outputs depending on CCT and power-select as below:

Art. No. Length Power 3000K 4000K
Efciency Lumen Efciency Lumen
9972010 600mm 11/13/16/20W 115lm/W 11W-1265lm

13W-1500lm
16W-1800lm
20W-2300lm| 130lm/W| 11W-1400lm
13W-1600lm
16W-2000lm
20W-2500lm
9972011| 1200mm| 23/29/35/40W| 130lm/W| 23W-2990lm
29W-3770lm
35W-4550lm
40W-5200lm| 140lm/W| 23W-3200lm
29W-4000lm
35W-4900lm
40W-5600lm
9972012| 1500mm| 26/33/40/47W| 130lm/W| 26W-3300lm
33W-4300lm
40W-5200lm
47W-6100lm| 140lm/W| 26W-3600lm
33W-4600lm
40W-5600lm
47W-6580lm
9972013| 600mm| 11/13/16/20W| 115lm/W| 11W-1265lm
13W-1500lm
16W-1800lm
20W-2300lm| 130lm/W| 11W-1400lm
13W-1600lm
16W-2000lm
20W-2500lm
9972014| 1200mm| 23/29/35/40W| 130lm/W| 23W-2990lm
29W-3770lm
35W-4550lm
40W-5200lm| 140lm/W| 23W-3200lm
29W-4000lm
35W-4900lm
40W-5600lm
9972015| 1500mm| 26/33/40/47W| 130lm/W| 26W-3300lm
33W-4300lm
40W-5200lm
47W-6100lm| 140lm/W| 26W-3600lm
33W-4600lm
40W-5600lm
47W-6580lm

Instruction for Light Source Disassembly

99 720 13-15 Malmbergs Breda LED - Source Disassembly

NOTE! The light source is non-user replaceable and must only be replaced by the manufacturer, its service agent or a similar qualified person. This product contains a light source of energy efficiency class C.

EMC Standard (EMC)
EN IEC 55015:2019+A11:2020, EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019, EN61547:2009
Safety Standard (LVD)
EN IEC 60598-2-1:2021, EN IEC 60598-1:2021, EN 62493:2015, EN IEC 62031:2020, IEC 60598-2-24:2013 used in conjunction with IEC 60598-1:2020
RoHS Standard (RoHS)
IEC 62321-3-1:2013, IEC 62321-1:2017
Declaration of Conformity
We hereby certify that the device satisfies the provisions for CE/D markings in accordance with the EU directives (LVD Directive 2014/35/EU, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU, (EU) 2015/863) as described in this manual.

For and on behalf of:

Malmbergs Elektriska AB, Sweden.
Mr. Peter Karlsson / Product Manager
Date: 31/03/2023

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MALMBERGS User Manuals

Related Manuals