RONGTA Y1 Aurora Series PC Scale User Manual

June 5, 2024
RONGTA

User Manual
AURORA Series PC SCALE

Introduction

Thank you for choosing our PC Scale. In order to operate the PC Scale correctly, a User manual is detailed in the function and operation method of the PC Scale, which helps the user with doubt quickly when coming up against mechanical fault . Rongta researched, develop, produce, and sold the PC Scale independently, which is a high-performance PC Scale. PC Scale is the best choice for users in label printing business lines with fashion appearance, power function, and high durability, which make PC scale more popular in stores, fresh food supermarkets, farmers’ markets,s and so on.

Note: this product information is subject to change without prior notice. This information is for reference only. In addition to China’s existing laws and regulations, the company does not undertake any due to the direct or indirect losses caused by the use of this information. The company reserves the final interpretation.

Specification of PC scale register

  • The Weighing range and accuracy:
Max weight: 15kg Max weight: 30kg
Min weight: 40g Min weight: 100g
0kg to 6kg * 0.002kg (e=2g) 0kg to 15kg * 0.005kg (e=5g)
6kg to 15kg * 0.005kg (e= 5g) 15kg to 30kg * 0.01kg (e= 10g)
  • The accuracy grade:
  • Resolution

Input sensitivity: greater than or equal to50μV/D
zero-point adjustment range: ±60MV
temperature coefficient: ±0.0012%CTYP
[Zero] ±(0.2μV+0.0008% of Dead Load)/℃TYP

Nonlinearity: 0.01%F.S.
A/D resolution: Max 30000 resolution
Display resolution: 1/3000
A/D conversion rate: 10 times/second

  • Regular:

Power supply: AC100~240V,50/60Hz
Power consumption: Standby25W, printing45W
operating temperature: 0℃-40℃
Physical appearance: 372×450×500mm

Standard configuration of PC scale register

The pictures of AURORA series and derivative models (main screen, customer display, small screen, label module, etc. are optional) are for reference only, and the actual product shall prevail.

PC scale installation steps

3.1 Assembly step


1. Place the scale in a level and stable place and remove the three transport protection screws from the scale pan bracket.| 2. Observe the level vial, Adjust the feet to make the level tool inside the little circle, Place the scale pan horizontally on the scale body

3.2 The installation of the thermal receipt paper

  • Pull the Open Cover to open the paper warehouse.

  • Open the side cover, remove the paper roll press block

  • Close the paper roll press block, tighten the paper winding shaft, screw the headpiece pressure lever, close the side cover of the printer, Long press the FEED button until the light flashes and then let go.

  • Put the paper roll into the paper warehouse as shown in the figure

  • Close the cover of the printer, and press upward gently until the cover closed with a “click” sound.

  • Unscrew the headpiece pressure lever and load paper as shown in the figure. (There are decorative paper tips in the module)

Overall Appearance

4.1 Front view

4.2 Rear view

Common easy-to -use operations

5.1 Switch on and off
Hard disk switch:

After connecting the power supply,long-press the black POWER button on the front of the PC scale register for 3s until the display is turned on. After entering the normal operation screen, the program will automatically run and perform self-test counting to verify whether the CRC is correct. If verification fails, the scale cannot work normally.

Attention: Under self-test situation, please do not press any button and make sure nothing is on the scale, otherwise, it can’t work normally Soft disk switches on/off:

Touch [Power Off] in the system or Please switch on the power button, then press the button [ON/OFF] for 3 seconds.
5.2 Weight display

Key Description
Tare : This operation is only suitable for weighing commodities that need to be packaged, such as eggs, beans, etc.
There are two methods used when the package is separated from the product and the package is not separated from the product.
Zero : Press the button [ZERO] to make zero of all the data. (Note: more than 300g can not be returned to zero)
Reset : Used to restart the weighing module.

5.3 Communication Interface
The factory communication interface of the product is fixed at COM2 and cannot be changed through other software. Communicating through other interfaces is also not supported.
5.4 PC scale interface
5.4.1 Ethernet interface
The Ethernet interface socket of the PC scale is standard RJ45-8P, it supports a 10M/100M network, and the transmission speed is adaptive.

Pin number Description Illustration
1 TX+ Send differential line+
2 TX- Send differential line-
3 RX+ Receive differential line+
4 NC No function
5 NC No function
6 RX- Receive differential line-
7 NC No function
8 NC No function

5.4.2 Cashbox Interfaces of Printers
The cashbox interface of the printer adopts RJ-11 standard, 6-wire socket, and outputs DC 24V/1A power signal to drive the cashbox. Insert the RJ-11 crystal connector of the cashbox into the cashbox interface to open the cashbox through the printer.

Pin number Signal Description
1 GND Power supply ground
2 Dk1 Negative pole of cashbox 1#
3 DK-1 N Start detection
4 PWR Positive supply/cashbox pole of power
5 Dk2 Negative pole of cashbox 2#
6 G N D Power supply ground

5.4.3 Serial Interfaces of Printers
The serial port of the PC scale adopts the RJ9 standard and the functions of each pin of the serial interface are defined as follows:

Pin number Model Signal source Description
1 3.3V Host Power supply 3.3V
2 TXD Host The printer sends data to the host.
3 RXD Printer The printer receives data from the host.
4 GND Host Signal ground

5.4.4 USB interface

PIN SIGNAL NAME
1 VVC 5V
2 D-
3 D+
4 GND

Troubleshooting of PC scale register

6.1 Crash or fail to start
Reasons: a.Powerboard error
b. Power line and interface error
c. Mainboard error
Solutions: a. Re-plug the power line
b. Press the [Power] button for 3 seconds. If the printer indicator is off, it means the power board is abnormal; otherwise, the mainboard is abnormal

6.2 The main display screen or customer display screen does not display or the display screen is blurred

Reasons: a. Screen line error
b. Poor contact of screen line connector
c. The display screen is damaged, or the mainboard is damaged
Solutions: a. Reconnect the screen line aerial connector and confirm that the line sequence is correct
b. Re-plug the screen line connector
c. If it still fails, it may be caused by screen damage or mainboard damage

6.3 The touch screen cannot be used or is not sensitive

Reasons: a. Display cable error.
b. Display driver error.
Solutions: a. Reconnect the screen line aerial connector and confirm that the line sequence is correct
b. Reinstall the correct driver

6.4 Unable to print
Reasons:
a. Print wire error.
b. The driver is not installed correctly.
c. Print board error.
Solutions:
a.If the printer indicator is off after being turned on, it means the wires are defective.
b.Reinstall the correct driver.
c.Press and hold FEED button to print the self-test page.

6.5 Unable to weigh properly (please contact the After-sales Service)
Reasons:: The main board or AD board fails, the sensor fails, or the CRC check fails.
Solutions: Please contact us, and we will provide you new version AD board program or weighing software.

Appendix Comparison Table of Gravitational Acceleration Corrected Value

COUNTRY CITY G(m/sec2) COUNTRY CITY G(m/sec2)
Greece Athens 9.800 Scotland Glasgow 9.816
South Cape town 9.796 Spain Madrid 9.800
Netherland Amsterdam 9.813 Singapore Singapore 9.781
Norway Oslo 9.815 Argentina Buenos Aires 9.797
New Auckland, NZ 9.799 United London, Greenw 9.812
New Wellington, NZ 9.801 Australia Melbourne 9.800
Taiwan Taichung 9.789 Australia Sydney 9.797
Taiwan Taiwan 9.788 Italy Milano 9.806
Taiwan Taipei 9.790 Italy Rome 9.803
Denmark Copenhagen 9.815 India Calcutta 9.788
Germany Frankfurt 9.810 Japan Tokyo 9.798
Mexico Mexico City 9.779 Canada Ottawa 9.806
U.S.A Birmingham 9.813 Canada Vancouver, BC 9.809
U.S.A Chicago 9.803 Cuba Havana 9.788
U.S.A Los Angles 9.796 Kuwait Kuwait 9.795
U.S.A New York 9.802 Cyprus Nicosia 9.797
U.S.A San Francisco 9.800 Thailand Bangkok 9.783
U.S.A Washington, DC 9.784 Portugal Lisbon 9.801
Belgium Brussels 9.811 France Paris 9.809
Brazil Rio de Janeiro 9.786 Finland Helsinki 9.819
Sweden Stockholm 9.818 Philippines Manila 9.784
Switzerland Zurich 9.807
COUNTRY CITY G(m/sec2) COUNTRY CITY G(m/sec2)
Greece Athens 9.800 Scotland Glasgow 9.816
South Cape town 9.796 Spain Madrid 9.800
Netherland Amsterdam 9.813 Singapore Singapore 9.781
Norway Oslo 9.815 Argentina Buenos Aires 9.797
New Auckland, NZ 9.799 United London, Greenw 9.812
New Wellington, NZ 9.801 Australia Melbourne 9.800
Taiwan Taichung 9.789 Australia Sydney 9.797
Taiwan Taiwan 9.788 Italy Milano 9.806
Taiwan Taipei 9.790 Italy Rome 9.803
Denmark Copenhagen 9.815 India Calcutta 9.788
Germany Frankfurt 9.810 Japan Tokyo 9.798
Mexico Mexico City 9.779 Canada Ottawa 9.806
U.S.A Birmingham 9.813 Canada Vancouver, BC 9.809
U.S.A Chicago 9.803 Cuba Havana 9.788
  • It should be handled by a person in our company or dealers if want to adjust acceleration of gravity

ELECTRONIC CASH SCALE

| Rongta Technology (Xiamen) Group Co., Ltd.
ADD: No. 889 Xinmin Avenue, Tongan District, Xiamen, China WEB: www.rongtatech.com
TEL: 0086-592-5666129
FAX: 0086-592-5659169
---|---
https://www.rongtatech.com/

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals