CREATE 7 Stage Air Purifier with HEPA H13 and WiFi User Manual

June 5, 2024
CREATE

CREATE 7 Stage Air Purifier with HEPA H13 and WiFi

CREATE-7-Stage-Air-
Purifier-with-HEPA-H13-and-WiFi-image

Thank you for choosing our air purifier. Before using the appliance, and to ensure the best use, carefully read these instructions.
The safety precautions enclosed herein reduce the risk of death, injury and electrical shock when correctly adhered to. Keep the manual in a safe place for future reference, along with the completed warranty card, purchase receipt and package. If applicable, pass these in­structions on to the next owner of the appliance. Always follow basic safety precautions and accident prevention measures when using an electrical appliance. We assume no liability for customer failing to comply with these requirements.

SECURITY INSTRUCTIONS

When using any electrical appliance, basic safety precautions should always be observed.

  • Do not place on the following places:
    • Direct sunlight or facing outlet of air conditioner.
    • Unstable places(products may drop, resulting In Injury, cause leakage, electric shock or a fire accident).
    • Humid or high-temperature environment such as a bathroom, toilet or kitchen. (It may cause deformation, deterioration, discoloration and malfunction.)
  • Televisions and radios and other equipment nearby: Images may cause disorder and noise, the remote control can cause disruption to televisions and radios, please put more than 1 meter away.
  • In case of the pollen and other indoor dust, this product should be placed on the ground.
  • Pollen and dust easily fall near the floor, it is recommended that the product is placed on a flat ground in the room.
  • In order to make effective air circulation in the room there should be a gap of at least 20cm at both sides and back of the product, while 30cm from the top surface.
  • Do not place anything on the product (otherwise it may cause malfunction).
  • Note: Do not place magnets or metal objects.
  • Do not block the air inlet and outlet: for example, do not place anything into the outlet or front air inlet.
  • Do not lift or move the machine when it is working.
  • Never pull the cord when moving or storing the product, It may cause a short circuit or damage the power cord, get fire or get an electric shock accident.
  • Do not damage the power cord or plug, do not cut, excessive twist, pull or reverse the power line. If the power cord Is damaged, it must be replaced by the manufacturer, the maintenance department or professional staff to avoid any danger.
  • Do not use beyond the rated power, with a universal socket or other devices connected. It may cause the cord to overheat and cause fire accidents.
  • Do not touch the power plug with wet hands, it may cause electric shock.
  • Do not use your fingers or any metal objects into the air outlet gap, it may cause electric shock or injury.
  • Do not let water, flammable detergent or other liquid into the product, it may cause elec- tric shock or fire.
  • This product is not supposed to be used as daily ventilator, dust cleaner or cooker hood.
  • Do not use this product near any gas appliances, heating devices or near stoves.
  • Do not allow children to have access to the remote control.
  • Do not use the air purifier in an aromatherapy or scent insecticide environment:
  • Chemical residues may accumulate in the machine, then they can be released from the outlet and cause harm to your health.
  • After using insecticide, you should thoroughly ventilate the room before using the air purifier.
  • When the following occurs, please immediately turn off the power of the machine. (It may cause electric shock, sparks, or smoke):
  • Abnormal sound or vibration during operation.
  • Product odor, burnt smell.
  • Please regularly clean the power plug:
  • Pull out the power plug, wipe with a dry cloth.
  • If do not use electrical appliances for a long time, please pull unplug the air purifier.
  • Before maintenance, make sure to disconnect the power. Products may suddenly start, causing electric shock and injury.
  • Please safely insert the plug into the socket. Do not use damaged plugs or loose power sockets.
  • Please hold the plug insulated parts to pull out the power plug:
  • Use the power cord to pull off the plug from the power cord. If you pull the cord, it may cause power cord damage, electric shock, short circuit or a fire disaster.
  • When any of the following occurs, please immediately turn off the machine and contact the maintenance department:
  • A switch does not work.
  • The power cord or plug are abnormally heated.
  • Abnormal sound or vibration.
  • Any anomalies or malfunctions.
  • Unprofessional people are not allowed to install or uninstall the machine.

PRODUCT FEATURES

Pre-filter

  • The primary filtration uses an aluminium alloy filter located in the pre-filter. It is mainly used for filtering dust larger than 5 microns, including large dust particles, dander, pollen, floating debris, and other pollutants. It can be washed many times and used repeatedly.

Cold Catalyst Filter

  1. The catalytic decomposition reaction of the cold catalyst does not require UV rays, high temperature, or high pressure. In normal living environments it can play a catalytic ef­fect in controlling air pollution.
  2. The main components of the cold catalyst come from additives found in food and phar­maceuticals. It is non-toxic, non-corrosive, and non-flammable. Under normal temper­ature conditions, the catalytic reaction can remove formaldehyde, benzene, xylene, TVOC and other harmful gasses. The reaction creates water and carbon dioxide. It does not produce any secondary pollution. It is a safe and environmentally friendly product on the cutting edge, suitable for a healthy home.
  3. During the catalytic reaction, the cold catalyst itself is not directly involved in the reac­tion. The cold catalyst does not change nor is lost. Because of this, without any external damage, this filter will effective for more than five years. It is basically synched with the release of the formaldehyde for long-term control.

Cellular-Activated Carbon Filter
The cellular-activated carbon carries high efficient additives. It has good absorption and dust collection characteristics.

Antibacterial Cotton Filter
The antibacterial filter is a precision filter trapping particles with a diameter of 5 mi­crons. At the same time there is an antibacterial agent added into the filter, can effec­tively killing any airborne germs at an effectively killing 99% or more of bacteria.

High Efficiency HEPA Filter
The effective HEPA filter filters airborne germs, smoke and dust particles 0.3 microns large at a rate of 99% or more. In combination with the multifunctional filter, the HEPA filter can filter out microscopic particles larger than 20 nanometers in diameter, includ­ing bacterial mold, dust, allergens, and some viruses, while filtering out smoke. Accord­ing to the World Health Organization, the avian flu virus, influenza virus, and Legionella bacteria are greater than 20 nanometers. The HEPA filter can filter them out.

Sterilizing UV light
UV sterilization using 365 nanometer UV wavelengths light can kill a variety of airborne bacteria. The UV disinfection lamp is generally used for air, surface, and water disinfec­tion. It can purify the air, eliminate musty odors, as well as produce a certain amount of anions. This makes the air fresh while avoiding the spread of viruses in the air or on surfaces.

Anion Purifier

  • A large amount of anions are released into the air, which oxygen molecules then add to their outer shell to obtain a negative charge. It has an extraordinary ability to com­bine with positively charged floating dust, smoke, bacteria, and viruses indoors. This makes free floating debris fall, thus purifying the air and environment without harm to humans. These ultrafine particles are difficult to tilter out with common mechanical equipment. Anions in the air have a special ability to capture these harmful substances.
  • The smaller the size of the particle, the higher the capture rate. It is an effective way to eliminate these pollutants.

PARTS LIST

  1. Control panel
  2. Front panel
  3. Airinlet
  4. HandleCREATE-7-Stage-Air-Purifier-with-HEPA-H13-and-WiFi-fig-1

INSTALLING THE FILTER

Take out the filter from the machine:

  1. Open the cover.
  2. Take out the filters.
  3. Take the filter out of the packaging. (Make sure to remove the plastic bag off the filter before use.)CREATE-7-Stage-Air-Purifier-with-HEPA-H13-and-WiFi-fig-2

Install the filter and front cover:

  1. Install the antibacterial + HEPA compound filters. Note: Please ensure the tab side is facing you.
  2. Install the cold catalyst + activated carbon filters. Note: Please ensure the tab side is facing you.
  3. Install the pre-filter. Note: Please ensure the handle side is facing you.
  4. Install the front panel. (The machine will not run it it is uncovered.)CREATE-7-Stage-Air-Purifier-with-HEPA-H13-and-WiFi-fig-3

REPLACING THE FILTER

  1. Press the middle of the front panel, to make the upper button out of its position.
  2. Pull out the front panel.
  3. Take out the filters one by one.
  4. Fill in new filters one by one in the correct sequence.
  5. Clean the prefilter every 15 days.
  6. Clean the honeycomb activated carbon filter and cold catalyst filter every 60 days.
  7. Replace the prefilter every 2 years.
  8. Replace honeycomb activated carbon filter, cold catalyst filter, antibacterial and HEPA filter every 6 months.

CREATE-7-Stage-Air-Purifier-with-HEPA-H13-and-WiFi-
fig-4

Filter change reminding reset:
The machine has a filter change reminding function. It’s set at 1500 hours. Please replace the honeycomb activated carbon filter/ cold catalyst filter and antibacterial/ HEPA filter when the “change” icon lights up. Also please press the child lock button for 5 seconds to reset this function.

FUNCTION DESCRIPTION

Powering on
When the machine is plugged in and on standby, “POWER” button works to turn on the machine. After this button is touched for the second time, the machine turns to standby state. (The icon is red when standby and green when on.)

Selecting the Operating mode

Child lock
When the machine is on, touch “CHILD LOCK” button to lock all the but-tons. At that time all the buttons have no reaction to any touch, while the machine still works how it is set before. Press “CHILD LOCK” button for 3 seconds and the machine will quit this mode. (The icon will stay on when the machine operates in child-lock mode, otherwise it will be off.)

Ionizer
When the machine is on, pressing “INOIZER” button will turn on negative ion mode, and pressing one more time will turn it off. It will remain in low speed mode.

Timer
When the machine is on, every touch of “TIMER” button will add 30 min­utes to the timing. When it accumulates to 12 hours, one more touch will turn it off. (The icon will stay on when the machine operates in timing mode, otherwise it will be off.)

UV Sterilization
When the machine is on, pressing “STERILIZE” button will turn on UV ster­ilization mode, and pressing one more time will turn it off. (The icon will stay on when the machine operates in sterilization mode, otherwise it will be off.)

Auto
Press Auto button on the control panel, it will start auto mode. Auto in­dicator will light up on the panel. Under this mode, according to the de­gree of air pollution, automatic the air volume will automatically adjust. PM2.5<60 (Low speed), 60PM2.5<150 (Medium speed), PM2.5 AUTO 150 (High speed).

Sleep
In sleeping mode, all the lights turns off and the machine works at low speed. Press any button to wake it up and then press “SLEEP” button to quit sleeping mode.

Speed
In sleeping mode, all the lights turns off and the machine works at low speed. Press any button to wake it up and then press “SLEEP” button to quit sleeping mode.

Speed
Press this button to adjust the motor speed at Low(500RPM), Medi­um(700RPM) or High (900 RPM) speed and let the machine exit auto mode. The motor speed won’t be controlled by the sensor if it’s modified without permission.

Accumulated working time of the filter
Press child lock for 5 seconds when at normal working mode (child lock mode will not start), it will show accumulated working time of the filter. It will disappear after 3 seconds.

Wi-Fi
When the machine is on state, press the “IONIZE R” button and the Wi-Fi icon flashes to enter the CREATE HOME APP connection mode.

Powering off
If you press the power button on the operational panel while the machine is running, the machine will enter into standby mode.

Remote control

  • This product is equipped with a remote control. It uses a button cell (if you are not going to use the remote control for a long time, please take out the battery).
  • Note: The buttons on the remote control corresponding to the functions on the operation panel. Function and operation method are exactly the same.

HOW TO USE IT

  • Intelligent operation: When the machine is connected, press the power button so the ma­chine can run under the sensor intelligent induction. The operation of the motor gears will follow sensors adjusted value.
  • When the purifier is connected, press the power button and select a key according to wind speed motor gear, select on or off negative ions and UV germicidal lamp.
  • Child lock mode: As long as you press the Child lock button, the control panel and buttons on the remote control do not work. (Long press Childlock for 3 seconds to cancel it,or press the unlock button on the remote control.)

TIME SETTING

  • Setting method: Long press the timer key for 5 second and the time display will show the hour digit flashing. Press the speed key to add 1 hour and press the sleep button to subtract 1 hour. Once the hour is set, click the timer key again and the minutes digits will flash. Press the speed button to add 1 min and press the sleep mode to subtract 1 min.
  • Note: The timer function of this machine is completely independent, time display func­tion does not affect the purification.
  • The battery can last for 10 days in standby mode. When it runs out of battery, the clock function is automatically reset. You need to set the clock again.

CLEANING AND MAINTENANCE

  • Pre-Filter(Every 15 days): Please use a vacuum cleaner to clean the dust on the surface of the screen, or wash with water, dry throughly.
  • Cold-catalyst filter/ Honeycomb activated carbon filter (Every 2 months): Use a vacuum cleaner to clear the dust on the surface of the screen. Place the filter in a ventilated place. Don’t expose under the sunshine. Do not force the filter. Do not use water to clean the filter.
  • Antibacterial/ HEPA filter(Every 2 months): Place the filter in a ventilated place. Do not expose to sunshine. Do not use water to clean the filter.
  • Negative Ion Generator: When you hear the machine with a creek sound, use a brush as cleaning tool, regularly clean the dust around the negative ion generator.
  • Particle Sensor (Every 2 months): With a dry cotton swab clean regularly the lens to re­move the moisture and smoke, remove the outer cover of particle sensor, use the dry cotton swab to clean the lens. Please ensure to disconnect the power before cleaning.

Tips

  • Ensure to disconnect the power before cleaning and maintenance.
  • Do not open the machine when you are going to remove the filter.
  • Please unplug the power if the machine is not in use for a long time.
  • Depending on the places you are using the purifier and the methods you follow (e.g. A family with many smokers or a place with serious pollution), the filter life will be short­ened. Please replace the filter in time.

TROUBLESHOOTING

CREATE-7-Stage-Air-Purifier-with-HEPA-H13-and-WiFi-
fig-6

In compliance with Directives: 2012/19/EU and 2015/863/EU on the restriction of the use of dangerous substances in electric and electronic equipment as well as their waste disposal. The symbol with the crossed dustbin shown on the package indicates that the product at the end of its service life shall be colected as separate waste. Therefore, any products that have reached the end of their useful life must be given to waste disposal centers specializing in separate collection of waste electrical and electronic equipment, or given back to the retailer at the time of purchasing new similar equipment, on a one for one basis. The adequate separate collection for the subsequent star treated and disposed of in an environmentally compatible way contributes to preventing possible nega- tive effects on the environment and health and optimizes the recycling and reuse of components making up the apparatus. Abusive disposal of the product by the user involves the application of administrative sanctions according to the laws. -up of the equipment sent to be recycled.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CREATE User Manuals

Related Manuals