xantrex 808-0822 Freedom X Combox Owner’s Manual

June 5, 2024
xantrex

808-0822 Freedom X Combox
Owner’s Manual

xantrex 808-0822 Freedom X Combox

DANGER
RISK OF ELECTRIC SHOCK AND EQUIPMENT DAMAGE

  • Connect only to Safety Extra Low Voltage (SELV) circuits and power sources.
  • Do not expose the Combox to rain, snow, spray, or bilge water. For indoor use only.
  • Do not disassemble. No user-serviceable parts inside.
  • Do not install and/or operate in compartments containing flammable materials or in locations that require ignition-protected equipment.
    Failure to follow these instructions will result in physical injury and/or equipment damage.

Exclusion for Documentation
UNLESS SPECIFICALLY AGREED TO IN WRITING, THE SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY, OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION; (B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK; AND (C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION ACCURACY CAN NOT BE GUARANTEED. APPROVED CONTENT IS CONTAINED IN THE ENGLISH  LANGUAGE VERSION WHICH IS POSTED AT http://WWW.XANTREX.COM.
NOTE: Visit http://www.xantrex.com, click Products, select a Product category, select a Product, and search the Product Documents panel for a translation of the English guide, if available.

Contact Information
Telephone: +1-800-670-0707 / +1-408-987-6030
Email: [email protected],
http://www.xantrex.com/power-products-support/
Web: http://www.xantrex.com
xxxxx

Introduction

The Freedom X Combox is a single-box communications hub from Xantrex that is capable of interfacing with a Xantrex Freedom X | XC series device and allowing that device to communicate with an RV-C device. The Combox is also able to connect to the Freedom X remote panel (with or without Bluetooth) in order to access and control the Freedom X | XC series.

xantrex 808-0822 Freedom X Combox - Introduction

A Freedom X Com box D 2x mounting screws 6-20×1/2″
B 25-ft cable (PN: 31-6257-00)

To order a 25-ft cable, contact customer service with product number 31-6257-00.| E| Owner’s Guide
C| RV-C 4-pin connector with pigtail| NOTE| If any of the items are missing, contact your Xantrex dealer.

Mounting

xantrex 808-0822 Freedom X Combox - Mounting

Ports

A| Non-functional port.
RESERVED FOR FUTURE USE.
---|---
B| SCC (solar charge controller) port – connect to a Xantrex Solar Charge Controller device.
RESERVED FOR FUTURE USE.
C| RV-C port – connect to an auxiliary device such as a compatible RV controller and monitor.
D| NMEA 2000 (Micro-C) port – connect to an auxiliary
NMEA 2000 compatible devices such as a vessel monitoring system (VMS).
E| USB host port – used for firmware upgrades and device configuration only.
**DO NOT USE IT TO POWER AND CHARGE USB DEVICES.
F| Remote display port – connect to a compatible Freedom X remote panel unit.
G| Device port – the power to the unit and also communications data are supplied here from a Xantrex Freedom X I XC series device.
| See
5** for a typical connection setup.

Port Pin Assignments

xantrex 808-0822 Freedom X Combox - Port Pin
Assignments

A CAN_Shield
B CAN_L
C COM
D CAN_H
E CAN_L
F CAN_H
G COM
**** Match port pin assignments to connector pins carefully. See section

9

LED Status Indicators

Inverter| Green| The Sandbox is connected to a Freedom X I XC sales unit and the unit is ON.
---|---|---
Flashing green| The Sandbox is connected to a Freedom X I XC sales unit and the unit is at Standby.
Off| Freedom X I XC series twit is disconnected from its battery source a Can box is disconnected from a Freedom X I XC series twit
Status| Green| Sandbox App activity
Flashing red| Sandbox detected a USB and is loading up new firmware
USB| Green| USB-related operation is successful
Flashing green| Active USB•related operatic(‘
Red| USB-related operation is unsuccessful
Flashing red| Active USB•related operatics,
Amber| USB drive is plugged in
Flashing amber| Active USB•related operatics,
Off| No USB drive detected
CAN| Green / Flashing green| CAN device detected and operating
Off| No device detected
SCC| Green / Flashing green| SCC (Xantrex Solar Charge Controller) detected and operating
Off| No device detected

1 USB-related operation includes loading and applying firmware updates, copying and applying device configurations, and data logging.

Typical Connection Diagram

You can connect only one power source which is the Freedom X | XC series. The Combox has no power switch. As long as the Combox and the Freedom X | XC series are connected and Freedom X | XC series is connected to a battery, the Combox will receive power.
Only one auxiliary device can be connected at any time. In this diagram, a universal control monitor is connected via the RV-C port.
****CAN network 120-ohm termination may be required.

xantrex 808-0822 Freedom X Combox - Connection Diagram

A Freedom X Com box E Optional Freedom X remote panel
B 25-ft cable (PN. 31-6257-00) (supplied). Connect to REMOTE pat on the
Freedom X I XC series F RV-C can cable (not supplied). Splice wires

correctly with item G.
C| Freedom X I XC series| G| RV-C 4-pin connector with pigtail (supplied)
D| 25-ft cable supplied from the optional Freedom X remote panel| H| An Auxiliary RV-C device is typically a universal control panel

Troubleshooting

PROBLEM CAUSE SOLUTION
The Com box’s LED indicators do not seem to be lighting up. The Combox is not
receiving power. Check that the Freedom X I XC series is connected to a

battery.
Check that the 25-ft cable (PN: 31-6257-00) has been plugged correctly to both the Combox and Freedom X I XC series’s RJ-12 Remote ports.
Check that a battery is connected to the Freedom X I XC series for power.
The auxiliary RV-C device is not receiving information.| RV-C 4-pin connector with pigtail is wired incorrectly.| Check that CAN wires are terminated properly and correspond to the PORT (pin) assignments.
The Combox is not receiving power.| Check that the Freedom X I XC series is powered and is connected by RJ-12 cable to the Com box.
The Freedom X remote panel device is not receiving information.| The Combox is not receiving power.| Check that Freedom X remote panel is powered and is connected by RJ-12 cable to the Combox.

Specifications

NOTE: Specifications are subject to change without prior notice.

Electrical Specifications

Communication interfaces Serial| 2 x labeled RJ-12 ports. Protection from the interchange.
Xantrex Device Supported: Freedom X I XC series and Freedom X remote panel
SCC| 1 x RJ-45 port
RV-C| CANbus terminal requires one RV-C 4-pin connector with pigtail or equivalent: 4-terminals. 16- 24AWG. pin assignments to match port assignments.
NM EA 2000| NM EA 2000 (Micro-C) terminal requires a matching male connector Zero network load
Data Interface USB 2.0-Host| USB-A. MSD protocol for firmware and device upgrades only. .!. DO NOT USE TO POWER AND CHARGE USB DEVICES.
Power supply (SELV) via RJ-12 Remote port of the Xantrex Freedom X I XC series I Xantrex Solar Charge Controller| Power input voltage range: 10-32V=
Power input current including Freedom X remote panel: < 130mA at 12V= Standby power: 0.8W. < 70mA at 12V=
Physical Specifications
| A-3.1 in. (79.5mm) including port
B-1.2 in. (30.7mm)
C – 6 in. (151.5mm) with flanges
Weight| 0.51b (227 g)
Physical Specifications

Housing / Mounting System| ABS Plastic. Wall-mount 2-screw
IP rating / Mounting Location| IP 20. NEMA Type 1. Indoor only
Status Display| 5 x LEDs
Temperature| Operating: -4 to 127F (-20 to 50°C) I Storage: -40 to 185°F (-40 to 85°C)
Humidity| Operating: < 95%. non-condensing I Storage: < 95%. non-condensing
Regulatory
North America (US. CA) EMI| FCC Part 15 Class B. ISED Canada ICES-003 Class B
European Union (EU)| | EU Mark| Regulations| Test Standard| Comments
---|---|---|---
E-mark| EN/EU Regulation| ECE R10.06| Automotive EMC —
Regulation 10- EMC emissions 8 transients
Automotive EMC Standard| EN 504982010| Automotive Bectromagnelic Compatibility (EMC) — Emissions and immunity
CE Marking| EMC Directive 2014/30/ EU| EN AEC
61000-6-32020| Residential Generic —Emissions
EN AEC
61000-6-12016| Residential Generic —Immunity
GPS Directive 2001 / 95/ EC| ENAEC 62368- 12318| Audio/video, information, and communication technology equipment —
Part 1: Safety requirements
RoH53″
Directive
2011/65/EU| EN 630002018| Health Safety —Restriction of Handous Substances

Components

To order Xantrex products, contact an authorized Xantrex dealer. The Freedom X Combox requires one power source.

| Compatible
devices| Freedom X I XC series
Compatible PNs: 817-1000, 817-2000, 817-2000-12, 817-2000-21, 817-3000, 8171050, 817-2080
---|---|---
| Compatible device| Xantrex Solar Charge Controller
Compatible PN: 710-3024-01 (available when SCC port is activated for use)
| Optimal| Freedom X remote panel with 25-ft corn cable Compatible PNs: 808-0817.01, 808-0817.02
| Optional| Patch cable with RJ-45 connectors
| Optional| 25-ft RJ-12 6-conductor corn cable PN: 31.6257-00
| Supplied| RV-C 4-pin connector with pigtail
| Supplied| 25-ft cable (PN: 31-6257-00)

975-1034-01-01 Rev B
July 2021

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

xantrex User Manuals

Related Manuals