NUVO 65-820 Satco Led Vapor Tight & Tri-Proof Linear Fixtures Instruction Manual

June 5, 2024
NUVO

LED VAPOR TIGHT & TRI-PROOF LINEAR FIXTURES
Models: 65-820, 65-821, 65-822, 65-823, 65-824, 65-825,
65-830, 65-831, 65-832, 65-833

INSTALLATION AND SAFETY INSTRUCTIONS

IMPORTANT: Read before installing fixture. Retain for future reference.

WARNING: Risk of Fire or Electric Shock

  • Only authorized, qualified personnel should install this fixture and should follow the owner’s manual. Any improper installation might cause failure, electric shock, fire, or another injury, damage, or hazard.
  • Disconnect power before installation or any maintenance of the fixture.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during installation.
  • Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind, or tree swing.
  • Rated for 120–277V use with min. 75˚ C supply wire.

IMPORTANT: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.

VAPOR TIGHT FIXTURES

65-820 2′, 20W
65-821 4′, 40W/50W/60W
65-822 8′, 50W/60W/72W
65-823 2′, 20W, w/Sensor
--- ---
65-824 4′, 40W/50W/60W, w/Senor
65-825 8′, 50W/60W/72W, w/Sensor

TRI-PROOF FIXTURES

65-830 2′, 20W
65-831 4′, 40W/50W/60W
65-832 2′, 20W, w/Sensor
--- ---
65-833 4′, 40W/50W/60W, w/Sensor

VAPOR TIGHT FIXTURE INSTRUCTIONS

  • Use appropriate hardware (supplied) to secure the fixture for surface or suspension installation.
  • Recommended mounting bracket distances for 2ft = 290mm, 4ft = 833mmm, 8ft = 2042mm, with a tolerance of +/–10mm.
  • Use size M6 to drill installation holes.

Surface Installation

STEP 1: Mark the surface using the recommended mounting bracket distance Drill the holes and secure mounting brackets with screws provided.

STEP 2 : Attach fixture to surface with the mounting brackets.

Suspension Installation

(Suspension kit not included)
STEP 1 : Mark the surface using the recommended mounting bracket distance. Drill the holes and secure the cables and mounting brackets with screws provided.
STEP 2 : Attach fixture to suspension cables with the mounting brackets.

TRI-PROOF FIXTURE INSTRUCTIONS

  • Use appropriate hardware (supplied) to secure the fixture for surface or suspension installation.
  • Recommended mounting bracket distances for 2ft = 400mm, 4ft = 900mmm, with a tolerance of +/–50mm.
  • Use size M5 to drill installation holes.
  • Use a screwdriver to open the Rubber Plug and preset the appropriate CCT and Wattage.

STEP 1 : Mark the surface using the recommended mounting bracket distance. Drill the holes and secure mounting brackets with screws provided.
STEP 2: Attach fixture to surface with the mounting brackets.

(Suspension kit not included)
STEP 1 : Mark the surface using the recommended mounting bracket distance. Drill the holes and secure the cables and mounting brackets with screws provided.
STEP 2 : Attach fixture to suspension cables with the mounting brackets.

WIRE CONNECTION INSTRUCTIONS

Vapor Tight Fixtures

STEP 1 : Open the stainless buckle, and unlatch the PC Cover parts from the bottom housing.
STEP 2 : Adjust the CCT & Wattage Selectable Dip Switch to the proper position.
STEP 3 : Insert the input cable through the Conduit Plug, and connect wiring to the corresponding colored wires using the Connect Nuts. See Wiring Diagram.
STEP 4: Replace the PC Cover to the bottom housing, close the Stainless Buckle.

WIRING DIAGRAM

Tri-Proof Fixtures

STEP 1 : Use a screwdriver to open the End Cap.
STEP 2 : Connect wiring to the corresponding colored wires using the Connect Nuts. See Wiring Diagram.
STEP 3 : Close the End Cap.

MOTION SENSOR STRUCTURE

Settings

By selecting the combination on the DIP switch, Motion Sensor data can be set precisely for each specific application.

| 100%
---|---
| 50%

Detection Area
In this area, movement will be detected and able to trigger the sensor. 100% detection area is also known as the strong sensitivity.

**** 5s
**** 30s
**** **** 1min
**** 10min

Hold-Time
The period of light keeps 100% brightness after moving objects leave the detection area.

**** **** Disable
**** 50lux
**** 10lux
2lux

Daylight Threshold
Definition of the ambient brightness; only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it’s preset as “disable”, the sensor works every time it detects motion regardless of the ambient brightness.

**** **** 0s
**** 30s
**** 20min
+∞

Stand-by Period
The period of light keeps low output before it’s completely switched off. When it’s preset as”∞“,  the light always stays at low output if no movement in the detection area and doesn’t turn off.

**** **** 10%
**** 20%
**** 30%
50%

Stand-by Dimming Level
The definition of low output in the standby period.

User Notes

  • The detected surface cannot be shielded by metal objects.
  • The detection surface of the sensor module shall be installed facing the detection area.
  • Wiring must be strictly in accordance with the wiring diagram to avoid short circuits.
  • Do not install in a place with all four metal shelters and small spaces (such as a galvanized-iron roof).
  • Avoid mounted installation, so as to prevent false triggers caused by the lamp itself shaking.
  • Avoid installation next to large operating machines such as ventilator/ceiling fans to avoid false triggering caused by machine vibration.
  • The driver voltage must be stable and float within 10%.
  • Detection area will be affected by the speed of motion, mounting height, and movement volume.
  • Conduct test on sunny days without the lampshade which will affect the tested lux value.