SAFETY INSTRUCTIONS

WARNING: Risk of Fire or Electric Shock

  • This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • TURN OFF the electrical power before proceeding.
  • To reduce the risk of fire and over-heating, secure all connections are tight.
  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Installation, service and maintenance of luminaries should be performed by a qualified licensed electrician.
  • This recessed downlight is intended to be connected to a properly installed and grounded UL listed junction box.
  • Do not install if product is damaged.
  • Always wear gloves and safety glasses when removing downlight from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.
  • Damp location rated.

Specifications

Model #| Watts| Ceiling Aperture (Hole cut size)| Lumens| Adjustable Color Temp.| Volts
---|---|---|---|---|---
S11850| 12| 4.17″ (106mm)| 1200| 2700K

3000K

3500K

4000K

5000K

| 120 –

277V

S11851| 16| 6.02″ (153mm)| 1600
S11852| 22| 7.99″ (203mm)| 2200
S11853| 32| 9.45″ (240mm)| 3200

Operating Temperature = -20C (-4F) to a maximum of +45C (+113F)

INSTALLATIONS

RETROFIT INSTALLATION

RETROFIT INSTALLATION

STEP 1: TURN OFF the electrical power at fuse or circuit breaker box before wiring fixture to power supply. (Figure A)

STEP 2: Locate a suitable position to install the fixture and create a hole in accordance to the dimensions. (Figure B)
NOTE: For NEW CONSTRUCTION see reverse for installation instructions.

STEP 3: Verify that supply voltage is correct by comparing it with the downlight specification. Install a Junction Box. Make wiring connections as per wiring diagram. (Figure C) Connect the hot power line (L) wire into the wire lead from the Driver, connect the neutral (N) wire lead to the neutral wire lead from the driver. If using 0-10V dimming; connect the purple (+) wire lead from the driver to the dimming control lead, connect the gray (–) wire lead from the driver to the dimming control gray wire lead. (Figure C)

STEP 4: Important! The color temperature must be set on the fixture before installation into the ceiling. (Figure D)

STEP 5: Connect the fixture lead wire to the Junction Box. (Figure E)

STEP 6: The fixture can now be inserted into the ceiling by compressing the two spring clips to an upright position and carefully slide the fixture into the ceiling hole until the fixture trim flushes up against the ceiling surface. (Figure F)

STEP 7: Once assembly is complete, turn power ON to confirm fixture is working properly.

NEW CONSTRUCTION INSTALLATION

NEW CONSTRUCTION INSTALLATION

STEP 1: TURN OFF the electrical power at fuse or circuit breaker box before wiring fixture to power supply. (Figure A)

STEP 2: Verify that supply voltage is correct by comparing it with the downlight specification. Install a Junction Box. Make wiring connections as per wiring diagram. (Figure B) Connect the hot power line (L) wire into the wire lead from the Driver, connect the neutral (N) wire lead to the neutral wire lead from the driver. If using 0-10V dimming; connect the purple (+) wire lead from the driver to the dimming control lead, connect the gray (–) wire lead from the driver to the dimming control gray wire lead. (Figure B)

STEP 3: Important! The color temperature must be set on the fixture before installation into the ceiling. (Figure C)

STEP 4: Connect the fixture lead wire from the LED Junction Box securely to the fixture wire lead. (Figure D)

STEP 5: The fixture can now be inserted into the ceiling by compressing the two spring clips to an upright position and carefully slide the fixture into the ceiling hole until the fixture trim flushes up against the ceiling surface. (Figure E)

STEP 6: Once assembly is complete, turn power ON to confirm fixture is working properly.