MEAN WELL APC-8 Series 8W Single Output Switching Power Supply User Guide

June 3, 2024
MEAN WELL

MEAN WELL APC-8 Series 8W Single Output Switching Power Supply

MEAN-WELL-APC-8-Series-8W-Single-Output-Switching-Power-Supply-
PRODUCT

Features

  • Constant current design
  • Universal AC input / Full range
  • Class II power unit, no FG
  • Fully isolated plastic case
  • IP42 design
  • Small and compact size
  • Cooling by free air convection
  • Protection:Short circuit
  • No load power consumption <0.5W
  • 100% full load burn-in test
  • Low cost/ High reliability
  • 2 years warranty

Applications

  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.6)

GTIN cODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

APC-8 series is one 8W AC/DC constant current mode single output LED power supply. It accepts the full range input 90-264VAC and provides four models with different output current, 250mA, 350mA, 500mA and 700mA, respectively, that the small wattage LED applications employ the most frequently. Exploiting Class II design (without FG pin) and adopting the 94V-0 flame retardant plastic enclosure, APC-8 ideally fits the entry-level LED applications.

Model Encoding

SPECIFICATION

MODEL APC-8-250 APC-8-350 APC-8-500 APC-8-700




OUTPUT

| RATED CURRENT| 250mA| 350mA| 500mA| 700mA
OPERATING VOLTAGE RANGE Note.4| 16~32V| 11~23V| 8~16V| 6~11V
RATED POWER| 8W| 8.05W| 8W| 7.7W
RIPPLE & NOISE (max.) Note.2| 350mVp-p| 300mVp-p| 300mVp-p| 250mVp-p
NO LOAD OUTPUT VOLTAGE| 38V| 29V| 24V| 17V
CURRENT ACCURACY| ±8.0%
SETUP, RISE TIME| 500ms, 180ms / 230VAC        3000ms, 150ms / 115VAC at full load
HOLD UP TIME (Typ.)| 20ms/230VAC at full load




INPUT

| VOLTAGE RANGE Note.3| 90 ~ 264VAC         127 ~ 370VDC ( Note.5 )
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 82.5%| 81.5%| 81%| 80%
AC CURRENT| 0.15A/230VAC;0.3A/115VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition is removed.



ENVIRONMENT

| WORKING TEMP.| -15 ~ 70℃(Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.2%/℃ (0 ~45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes



SAFETY & EMC

| SAFETY STANDARDS Note.7| UL8750,CSA C22.2 No.250.0-08, BIS IS15885, EAC TP TC 004; BS EN/EN 62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN55024,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020


OTHERS

| MTBF| 14511.7K hrs min.     Telcordia SR-332 (Bellcore) ;  2275.9K hrs min.    MIL-HDBK-217F (25℃)
DIMENSION| 603023.5mm(LWH)
PACKING| 0.05Kg;144pcs/7.6Kg/0.70CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capactor.

  3. Derating may be needed under low input voltage, please check the static characteristic for more details.

  4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED-related applications, but please
    reconfirm special electrical requirements for some specific system design.

  5. When applying DC voltage for input, please connect the brown input wire to the positive side whereas the blue input wire to the negative side.

  6. This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)

  7. The model certified for CCC(GB19510.14, GB19510.1, GB17743, and GB17625.1) is an optional model. Please contact MEAN WELL for details.

  8. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5C1000m with fan models for operating altitudes higher than 2000m(6500ft).

  9. For any application note and lP waterproof function installation caution, please refer to our user manual before using.

※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Mechanical Specification

MEAN-WELL-APC-8-Series-8W-Single-Output-Switching-Power-Supply-
FIG-4

Block Diagram

MEAN-WELL-APC-8-Series-8W-Single-Output-Switching-Power-
Supply-FIG-5

Derating Curve

  • File Name: APC-8-SPEC 2022-07-29
  • Downloaded from