SOYAL AR-837-EL LCD Access Controller Instruction Manual

June 5, 2024
SOYAL

QR Code Access Controller
AR-837-EL
V220322

Contents

AR-837-EL:
1 Products

2 Terminal Cables

  1. SOYAL AR 837 EL LCD Access Controller - Terminal Cables

3 Tools Screws

Waterproof Strip X2

4 Optional

  • Ethernet:
    DMOD-NETMA10 (TCP/IP Module included RJ45 Connector)
    or
    DMOD-NETMA11 or (TCP/IP Module with POE function)

  • Any Wiegand Output Module (CN10)

  • AR-MDL-721V
    (Voice Module)

  • AR-321L485-5V
    (TTL to RS-485 Converter)

Key Features

  • Support both 125kHz and 13.56MHz dual-frequency RFID
  • Scan QR Code to easily open the door!
  • Support Date Limit or Frequency limit of QR Code access, with higher security!
  • Scan QR Code images on smartphones or printed on paper, with an E Series controller to quickly scan QR Code
  • It is convenient for you to obtain the permission of access control, not only able to scan QR Code, but also supports EM and Mifare cards.
  • It is suitable for places that require the use of regular and short-term access, such as visitor systems, temporary building permits, dormitories, suite management, etc.

Specification

QRCode supported format:
(The standard firmware supports QR Code format as below and other QR Code formats can be supported by customized firmware.)

  • QRCo08A12345678
  • QRCo10A1234567890
  • QRCo14A12345678901234
  • QRCo55W1234556789
  • QRCo08H33CDAB88
  • QRCo16H001122334455667788
Type of Bar Code Density Min. distance Max. distance
Code 39 0.125 mm (5 mils) 4.0 cm 9.0 cm
0.375 mm (15 mils) 4.0 cm 25.0 cm
UPC/EAN 0.375 mm (15 mils) 4.0 cm 25.0 cm
Code93 0.254 mm (10 mils) 4.0 cm 21.0 cm

QR Code Scan Area

Testing under the lowest intensity of illumination (250 lux)

SOYAL AR 837 EL LCD Access Controller - QR Code Scan
Area

Installation

SOYAL AR 837 EL LCD Access Controller - Installation

  • A-1. Surface Mounted: Use a screwdriver to screw the mounting plate to the wall. A-2. Embedded: To dig a hole for AR-837-EL:128mmx109mm; and then, use a screwdriver to screw the mounting plate to the wall.
  • Pull cable ends through the access hole in the mounting plate.
  • Attach AR-837-EL to the mounting plate and install screws (supplied) into the holes at the bottom with the Allen key.
  • Apply power. LED (green) will light up with one beep.

Notice

  1. Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
  2. Wire selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring, CAT 5 cable for TCP/IP connection
  3. Power supply: Don’t equip the reader and lock with the same power supply.  The power for the reader may be unstable when the lock is activating, which may cause a malfunction in the reader.
    The standard installation: The door relay and lock use the same power supply, and the reader should use another independent power supply.

Connector Table (1)

Cable: CN4

Wire Application Wire Color Description
Lock Relay 1 Blue White (N.O.)DC24V1Amp
2 Purple White (N.C.)DC24V1Amp
Lock Relay COM 3 White (COM)DC24V1Amp
Door Contact 4 Orange Negative Trigger Input
Exit Switch 5 Purple Negative Trigger Input
Alarm Relay 6 Gray N.O./N.C. Optional (by jumper)
Power 7 Thick Red DC 12V
8 Thick Black DC 0V

Cable: CN5

Wire Application Wire Color Description
Beeper 1 Pink Beeper Output 5V/100mA, Low
LED 2 Yellow Red LED Output 5V/20mA, Max
3 Brown Green LED Output 5V/20mA, Max
Door Output 4 Blue White Transistor Output Max. 12V/100mA

(Open Collector Active Low)
Wiegand| 5| Thin Green| Wiegand DAT: 0 Input
6| Thin Blue| Wiegand DAT: 1 Input
WG Door Contact| 7| Orange| Negative Trigger Input
WG Exit Switch| 8| Purple| Negative Trigger Input

Cable: **CN6**

Wire Application Wire Color Description
RS-485 for Lift Controller 1 Thick Green RS-485(B-)
2 Thick Blue RS-485(A+)

Cable: **CN3**

Wire Application Wire Color Description
Anti-Tamper Switch 1 Red N.C.
2 Orange COM
3 Yellow N.O.

Cable: **CN8**

Wire Application Wire Color Description
Reserved 1 Red
Security trigger signal 2 Purple Security trigger signal Output
Arming 3 Red White Arming Output
Duress 4 Yellow White Duress Output

Cable:CN9 

Wire Application Wire Color Description

UART Port for extension module and functions.
support TTL to RS485 function with AR-321L485-5V for voice module(*Required speaker 8Ω / 1.5W (Max. 2W), lift control module,
swipe card automatically printed data online printer, LED board, Bluetooth
module, etc| 1| Black| DC 0V
2| Yellow| TX
3| White| TE
4| Orange| RX
5| Red| DC 5V
6| Blue| —

Cable:CN13

Wire Application Wire Color Description
Door Bell 1 Black White Transistor Output Max. 12V/100mA (Open Collector

Active Low)
2| Black| DC 0V

Connector Table (2): Optional

Cable:CN7

Wire Application Wire Color Description
1
2
TCP/IP Output 3 Orange White Net – TX+
4 Orange Net – TX-
5 Green White Net – RX+
6 Gerry Net – RX-
7

Cable: CN10

Wire Application Wire Color Description
1 Orange ANT 1
2 Purple ANT 2
3 Black DC 0V
4 Red DC 5V
5 Blue Wiegand DAT: 1 Input
6 Green Wiegand DAT: 0 Input
7 White

Wiring Diagram

Connect to Electric Bolt Connect to Magnetic Lock

SOYAL AR 837 EL LCD Access Controller - Electric Bolt| SOYAL AR 837 EL LCD Access Controller - Magnetic
Lock
Connect to Electric Strike| Connect to Door Contact
SOYAL AR 837 EL LCD Access Controller - Electric
Strike| SOYAL AR 837 EL LCD Access
Controller - Door Contact
Strengthen security with AR-721RB| Connect to Reader
---|---
SOYAL AR 837 EL LCD Access Controller - Strengthen
security| SOYAL AR 837 EL LCD
Access Controller - Reader
*AR-837-EL becomes WG mode (28`000#`)**
SOYAL AR 837 EL LCD Access Controller - WG mode| 1. When AR-837-EL becomes WG mode, it can be used with any controller.
2. When entering the Parameter Setting Window on 701Server, the device can be changed to WG Slave Mode by Enabling the “WG Output Mode” Option.

Programming

A. Keyboard Lock/ Unlock

Lock/ Unlock

  • Press ***** and # simultaneously lock the keyboard. Press simultaneously again to unlock.

B. Entering and Exiting Programming Mode

  • Entering
    Input *****123456 # or *****PPPPPP #
    [e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input ***** 876112 # → Access programming mode P.S.If no instruction is entered within 30 sec., it will automatically leave the programming mode.

  • Exiting
    Press the ***** ***** repeatedly → Quit 6 or 7 Quit and Arming (Please refer to alarm/arming setting

  • Changing the Master Code
    Access programming mode → 5 Tools → 2 Master Code → Input the 6-digit new master code → Succeeded

C. Initial setup

  • Language Setting
    Access programming mode → 5 Tools → 1 Language → 0 EN → Succeeded → Initial system…

  • Node ID of Reader Setting
    Access programming mode → 3 Parameters[1] → 1 Node ID → Input New Node ID : 1~254 (default value:001) → Main Door Number : 0~255 → WG1 Door Number : 0~255 → Show UID (0=No, 1=WG, 2=ABA, 3=HEX) → Enable DHCP(0:No, 1:En, 2=Exit) → Succeeded

Function Description of Front Panel & Indicator

SOYAL AR 837 EL LCD Access Controller - Front Panel

  1. The system will automatically exit Programming Mode when inactivating for 30 seconds.

  2. LED status indicates the controller’s mode and status.
    OK (green)
    – blinking constantly when operating in Programming Mode
    – or flashing an existed card in card learn mode, it comes with 2 beeps warning, and an LCD panel displays “Same Card: user address/card number”
    Error (red)
    – invalid card with 2 beeps warning and LCD panel displays “Card Number Err!”
    – or in anti-pass-back mode, when violates the access, it comes one beep warning, and the LCD panel displays “Anti-pass Error!”
    Arming (green) – arming on status
    Alarm (red) – any abnormal condition occurs

  3. The keypad will be locked up for 30 sec. when an incorrect pin code or master code is
    constantly entered.

  4. Maximum error input of pin code and master code can be changed via the
    software 701Server (default: 5 times)

Networking: / and interactively flash between the Month and DAY. [e.g.] 12/07←→12 07
Stand-alone: No flashing [e.g.] 12/07 (←Reference to picture)

Manu Tree

D. Adding and Deleting Tag
※ User capacity: 16384 (00000~16383)

  • Adding Tag by Tag ID
    Access programming mode → 1 Add/Delete → 1 Add -> Card ID → Input 5-digit user address → Input Site Code → Input Card Code
    Adding Tag by RF Learn Function
    Access programming mode → 1 Add/Delete → 2 Add -> RF-Learn → Input 5-digit user address → Input Tag Units(pcs) → Close Tag into RF Area
    ※If the batch of tags is Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with the lowest number to the controller for adding all the tag data; otherwise, the tags must be presented to the controller individually

  • Suspend User Address
    Access programming mode → 1 Add/Delete → 3 Suspend -> Addr → Input Start to address → Input End address

  • Suspend Tag by Tag ID
    Access programming mode → 1 Add/Delete → 4 Suspend -> ID # → Input Site Code → Input Card Code

  • Recover User Address
    Access programming mode →  1 Add/Delete → 7 Delete -> Addr → Input Start to address → Input End address

  • Recover Tag by Tag ID
    Access programming mode → 1 Add/Delete → 8 Delete -> ID # → Input Site Code → Input Card Code

  • Deleting User Address
    Access programming mode → 1 Add/Delete → 5 Delete -> Addr → Input Start to address → Input End address

  • Deleting Tag by Tag ID
    Access programming mode → 1 Add/Delete → 6 Delete -> ID # → Input Site Code → Input Card Code

  • Setting up the access mode
    Access programming mode → 2 User Setting → 2 Access Mode → Input User Address → 0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN

E. PIN Code
Access programming mode →  2 User Setting → 1 Password → Input 5-digit user address → Input 4-digit PIN (0001~9999) → Succeeded Or via 701Client set it on the Users screen
F. Access Mode
Access programming mode → 2 User Setting→ Access Mode→ Key in 5-digit user address (00000~08999) → 0: Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN → Succeeded
※If you choose an Access Mode that requires a PIN, please follow the quick command. Parameters(2)> . Miscellaneous and Pay attention to the choices in Time attendances/miscellaneous settings:
The main controller skips the PIN check. Select 0: NO
WG1 Port skip PIN check. Select 0: NO
If the PIN setting and the Access mode do not match, it will affect the controller’s interpretation error and prevent access.
G. Arming Password
Access programming mode → 3 Parameters[1] → 8 Arming PWD → Input 4-digit PIN (0001~9999; Default: 1234) → Succeeded
Or via 701Server and set it on the AR-829E screen
H. Arming Delay Time
Access programming mode → 3 Parameters[1] → 7 ArmingDelayTm → Enter armed sta. Delay time(Sec), Range:000~255;
Armed pulse out-put time (10ms), Range:000~255 → Succeed
I. Duress Code
Access programming mode → 4 Parameters[2] → 7 Duress Code → 4 sets (select one) → Input 4-digit PIN (0001~9999) → Succeeded
Or via 701Server to set it on the AR-829E-V5 screen
※Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to the computer as a warning signal.
J. Terminal Port
Access programming mode → **5** Tools → **4**Terminal Port → 0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) → Baud Selection
(default value:9600) → Succeeded
K. Setting up the alarm/arming

  • Conditions:
    1. Arming enabled
    2. Alarm system connected

  • Situations:
    1. Door is open over time: The door is open longer than door relay time plus door close time.
    2. Force open (Opened without a valid user card): Access by force or illegal procedure.
    3. Door position is abnormal: Happens when power is off and then on again, besides, the reader was on arming before the power went off.

  • Enable/Disable the arming status:
    Standby Mode

    Card only| Card or PIN| Card and PIN
    Open the door| No open the door| Input user address → Input
    4-digit individual PWD →#
    Input 4-digit arming PWD →#| Present the tag to the reader → Input
    4-digit individual PWD →#
    Input 4-digit arming PWD →#
    Present the tag to the reader → Input
    4-digit arming PWD →#| ***** → Input 4-digit arming PWD
    → Present the tag to the reader
    Access Programming mode
    Enable: Access programming mode → **7** Quit & Arming| Disable: Access programming mode → **6** Quit

※ [Use FP] can substitute for [Induct valid card].
L. Anti-pass-back

While connecting with AR-721-U, AR-737-H/U(WG mode), and AR-661-U for the anti-pass-back function, the access mode must be “Card” only.

  • Device enables
    Access programming mode → **4** Parameters[2] → 6 Anti-pass-back → master controller select [1: Yes] → WG select [1: Yes]

  • Card user enable
    Access programming mode → **1** Add/ Delete → **9** Antipas Group → Input 5-digit starting user address → Input 5-digit ending user addres s → must select [1: Yes]

M. Lift control
[e.g.] Connect with AR-401RO16B to control which floor the user will be able to access. (BAUD9600)

  • Setting Lift control
    Access programming mode → 5 Tools → **4** Terminal Port → 0:Lift Controller → Baud Selection 0: 9600
    Access programming mode → **5** Tools → **5** Terminal Port → 1:Lift Controller (need to use 725L485) Set| Floor/ Stop
    ---|---
    1| 1| 2| 3| 4| 5| 6| 7| 8| 9| 10| 11| 12| 13| 14| 15| 16
    0| 0| 0| 0| 0| 0| 0| 1| 0| 0| 0| 0| 0| 0| 0| 1
    2| 17| 18| 19| 20| 21| 22| 23| 24| 25| 26| 27| 28| 29| 30| 31| 32
    0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0
    3| 33| 34| 35| 36| 37| 38| 39| 40| 41| 42| 43| 44| 45| 46| 47| 48
    0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0
    4| 49| 50| 51| 52| 53| 54| 55| 56| 57| 58| 59| 60| 61| 62| 63| 64
    0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0

  • Single floor
    Access programming mode → **2**User Setting → **4** Single Floor →
    Input 5-digit user address → Input single floor number: 1~64

  • Multi floors
    Access programming mode → **2**User Setting → 5 Multi Floor → Input 5-digit user address → Select range: 1 or 2 or 3 or 4 → Input 16 digits
    multi floors number [0:disable, 1: enable]
    [e.g.] Set NO. 114, can use it through the 8 F and 16F:
    Access programming mode → **2**User Setting → 5 Multi Floor → 114 # → 1 #  → 0000000100000001 #

N. Alarm Clock (for Factory)
Access programming mode → **5**Tools → **9** Daily Alarm → Set (00~15) → Set Start Tm (24 Hours); Set Effect Sec.
(Seconds as the bell time, Range:1~255) → Set Weekday (0:disable, 1: enable) → Succeeded

  • Hardware installationSOYAL AR 837 EL LCD Access Controller - Hardware installation

O. OpenZone
Access programming mode →**3** Parameters[1] → **2**OnOff OpenZone → Main Controller Auto Open Zone (0:disable, 1:enable) →
Open Door Imm. During Open Zone (0:No, 1:Yes) → WG1 Port Auto Open Zone (0:disable, 1:enable) → Open Door Imm. During
Open Zone (0:No, 1:Yes) → Succeeded
P. Open TimeZone
Access programming mode → 5 Tools → **6** Open TimeZone → Set (00~15) → Time (24 Hours); Main Port (0:disable, 1: enable) ;
WG Port (0:disable, 1: enable) → Weekday (0:disable, 1: enable) → succeeded

**Firmware Upgrade

**

Get the upgrade software from SOYAL or our distributor and run the “UdpUpdater” software
Execute the software The software is within SOYAL CD or pleases log in to the SOYAL website to download SOYAL AR 837 EL LCD Access Controller -
Firmware Upgrade

  • Update the firmware
    [Please login the SOYAL website to download the new ISP Firmware.]
    1. Input the Target Address and Port
    2. [Load F/W] open the documents that have the new ISP Firmware
    3. Click the new ISP Firmware and [Open] it
    4. Click [Update F/W] to start the firmware update
    5. Till the screen shown [Firmware Update is Complete]

Restoring Factory Settings

Reset all device parameters and user card data

  • Reset all device parameters and user card data:
    Access programming mode → 4 Parameters2 → 9 Factory Reset →0: System Param ;
    1 : User Setting ; 2 : System & User

  • Reset IP Setting:
    When the device’s power is on, press the the【RESET】button on the mainboard until the ERR (Red)
    LED of the screen lights up. (Refer to the picture beside)

※ After the operation as above, you will hear a long reminder sound, wait until the sound disappears, and then reset the power of the controller. The device will be restored to factory settings.
※ After having done the “Factory Reset,” the External Communication Port must be reset. Or the biometric sensor won’t be functional.
5Tools → 5 Ext. Comm Port (0:FP-200 ; 1:Lift ; 2:Vein2000 ; 3:FP-9000 ; 4:Reserved )

IP Setting

  • Open your Web Browser and input the factory default IP address: http://192.168.1.127![SOYAL AR 837 EL LCD Access Controller - IP address](https://manuals.plus/wp-content/uploads/2022/05/SOYAL-AR-837-EL-LCD-Access-Controller-IP-address-550x117.png)

  • Page menuSOYAL AR 837 EL LCD Access Controller - Page menu

  • Current StateSOYAL AR 37 EL LCD Acess Contrller - Curren State Online Status is able to monitor and show which computer is linking to Ethernet Module

  • Log-in User Password When you choose the “Networking Setting” or “User Password” at first.
    The Log-in window will pop out and please input
    ※ At the Factory Default
    User name: SuperAdm
    Password: 721568

  • Networking SettingSOYAL AR 837 EL LCD Access Controller - Networking Setting
    You will find the initial IP Address 192.168.1.127 and check MAC Address is identical to the sticker on the Ethernet Module device. Please alter the IP address as you want, and then click the “Update” button. After updating the IP, please re-connect the Web Browser with the new IP address.

  • User PasswordSOYAL AR 837 EL LCD Access Controller - password Change the log-in password to lock the IP setting of the Ethernet Module.
    The password is composed of 10 characters at most which can be either A~Z or 0~9.

Setting Process of Generating / Receiving QR Code

Generate QR Code on 701 Client softwareSOYAL AR 837 EL LCD Access
Controller - Generate QR Code
Configure Email Server data on the “User-level Menu”
Step.1 Click “8 User Cards Edit”
Step.2 Select User Number one,
Step.3 Fill in Card ID, Select the specific Door Group, and Fill in “User Name”
Step.4 Assign the date limits, enter a start date, enter an expired date
Step.5 Click the Save button. The new QR code badge is generated.
Step.6 Click the “ download” button to download the user data to Controller.
Receiving QR Code waysSOYAL AR 837 EL LCD Access Controller - Receiving
QR Code ways

  • Save QR Code Image to the folder
    When clicking the button whether or not you configure Email, the QR code image will be saved to the path of
    C:\Program Files (x86)\701Client\PopGra with the filed name QRCodeXXXX.jpg (XXXX means User Address)

  • Send out QR Code via Email

  1. Configure Email Server data on the “User-level Menu”SOYAL AR 837 EL LCD Access Controller - Email Step.1 Click “ Access Level “
    Step.2 Setting Mail Server, User Name (Email Username), Password (Email Password), Mail From (Email Address)
    Step.3 Save after sending
    *Note: The personal email such as Gmail / Hotmail that don’t support the E-mail Server setting doesn’t support the function of sending our QR Code on 701Client Software

  2. Enter “Registry Editor” to configure Email ValueSOYAL AR 837 EL LCD Access Controller - imaeg 11 Add “SEND_QRCODE_EMAIL” under Settings/701Client/SOYAL,and Set its value to 1

  3. Fill in the assigned E-mail address; after clicking the button, the QR Code image will be sent to the assigned E-mail address.SOYAL AR 837 EL LCD Access Controller - Image 2324 Step.1 Fill in the E-mail address that needs to receive the QR Code.
    Step.2 Finally Click the QR Code Button, then the QR Code image will be sent to the assigned E-mail address, and also save to the image file under the path of C:\Program Files (x86)\701Client\ PopGra.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SOYAL User Manuals

Related Manuals