Firehawk FHB10W Optical Smoke Detector/Alarm Instructions

June 5, 2024
Firehawk

Pairing Radio Linked Alarms Instructions

Firehawk FHB10W Optical Smoke Detector Alarm -

CONNECT

1.0 Plug alarm into pattress and switch on radio base, the pattress led will flash green twice per second. If not please complete step 6.0

Firehawk FHB10W Optical Smoke Detector Alarm -
Instructions

ALARM ASSEMBLY

2.0 Bring alarm & radio base together then twist/slide to lock into place.

Firehawk FHB10W Optical Smoke Detector Alarm - ALARM
ASSEMBLY

Wait for the smoke or heat alarm to BEEP TWICE| Wait for the CO alarm to BEEP FOUR TIMES

Connect and assemble all of the alarms in your system before starting the pairing process.

PAIRING TWO ALARMS

Firehawk FHB10W Optical Smoke Detector Alarm - TWO
ALARMS

3.1 Group the alarms on the right-hand side of your table, then place two alarms in front of you spaced approximately 20cm APART.
3.2 Press the TEST BUTTON on one alarm and wait THREE SECONDS.
3.3 Press the TEST BUTTON on the other alarm.
3.4 Watch carefully as both alarms FLASH GREEN AND RED
3.5 As soon as one FLASHES GREEN ONLY, move it to the left of the table.
3.6 The other alarm will continue to FLASH GREEN AND RED until it BEEPS then it will FLASH GREEN (CO x4) THE TWO ALARMS ARE NOW PAIRED.
3.7 There is now a 10 SECOND WINDOW to allow another device to be added to the system
If no other devices are to be added proceed to Step 5.0

Firehawk FHB10W Optical Smoke Detector Alarm - added to the
system

PLEASE read all instructions BEFORE beginning to pair a system!

PAIRING ADDITIONAL ALARMS

4.1 To add additional alarms to the system simply PLACE THE PAIRED ALARM THAT BEEPED (see section 3.6) approximately 20cm apart from an ASSEMBLED ALARM (see point 2.0) UNPAIRED ALARM.
4.2 Press the TEST BUTTON on the PAIRED ALARM (THAT BEEPED) and wait THREE SECONDS.
4.3 Then press the TEST BUTTON on the UNPAIRED ALARM.
4.4 Repeat steps 3.4 to 3.6 until all alarms have been added.

TIP: Always pair from the PAIRED ALARM THAT BEEPED (this could be any of the previous alarms)

Firehawk FHB10W Optical Smoke Detector Alarm - previous
alarms

PAIRED ALARMS READY FOR INSTALLATION

5.1 If no other alarms are to be added to the system then allow the 10 SECOND window to elapse.
Watch each device whilst they continue to FLASH GREEN
5.2 To complete the pairing process each alarm will BEEP and FLASH GREEN
5.3 If any device fails to beep and FLASHES RED please reset all devices and repeat the pairing process.
5.4 Press the TEST BUTTON on one alarm and wait for each paired alarm to sound. (Due to signal timings it’s possible an alarm may not sound during testing. This does not necessarily indicate there is a connection problem). Please perform a test from said alarm, as well as each alarm in the system to confirm that all alarms are paired.

Firehawk FHB10W Optical Smoke Detector Alarm - TEST
BUTTON TIP: The most common mistake made during the pairing process is missing the 10 SECOND window
Install your alarms around your home, then test again with the alarms in position.

DEVICE RESET

6.1 To reset the mattress, remove the alarm device and press the black button. This will restore factory settings and unlearn all paired devices.
The Led will FLASH RED four times then begin to FLASH GREEN as in step 1.0.
6.2 Start again and repeat the pairing process.

Firehawk FHB10W Optical Smoke Detector Alarm - DEVICE
RESET

Fireblitz Extinguisher Ltd Units 15/17 Manford Industrial Estate, Manor Road, Erith, Kent DA8 2AJ.
Tel: 01322 342238 | Fax: 01322 331532 | Email: sales@fireblitz.co.uk | www.fireblitz.co.uk
Fireblitz reserve the right to change the design or specification details without prior notice.

REF: RADIOINSTRUCT09/20

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals