FireHawk FHB10-RF Optical Smoke Alarm User Guide

June 14, 2024
Firehawk

FireHawk FHB10-RF Optical Smoke Alarm User Guide
FireHawk FHB10-RF Optical Smoke Alarm

Pairing Guide

  • SMOKE ALARM FHB10-RF
    Product Overview

  • HEAT ALARM FHH10-RF
    Product Overview

  • CO ALARM CO10-RF
    Product Overview

  • HEARING IMPAIRED CONTROL UNIT FHN800HIA
    Product Overview

COMPATIBLE ALARMS

FireHawk RF-Link devices can be radio linked (wirelessly) to Smoke Alarms (FHB10-RF), Heat Alarms (FHH10-RF), Carbon Monoxide Alarms (CO10-RF), RF-Link equipped Mains Smoke and Heat Alarms (fitted with FHN600RF RF-Link module) and Hearing Impaired Control Units (FHN800HIA).

CONNECT

Plug alarm into pattress and switch on radio base, the pattress led will flash green twice per second. If not, please complete step 6.0 to reset the device.

Connection
Connection

Secure the alarm wire into the retaining slot

IMPORTANT: the wire can interfere with the radios antenna if not secured in the retaining slot.

ALARM ASSEMBLY

Bring alarm & radio base together then twist/slide to lock into place. The light will flash RED and the device will beep.

Repeat this procedure for each additional alarm in the system

LINKING

Press the TEST BUTTON on any assembled alarm, this will put it into linking mode and its light will flash red and green.

Press the TEST BUTTON on the next alarm to put it in linking mode, it will flash red and green.

Wait a few seconds for the alarm to beep and stop flashing its lights. The alarm is now linked.

Repeat step 3.2 & 3.3 for each alarm to be added to the system.

Once all alarms are linked, wait 20 seconds or press the test button on the first alarm to exit linking mode. If the test button is pressed on the first alarm to exit linking mode, the alarm will perform a test, step 4.1.

LINKED ALARMS READY FOR INSTALLATION

Press the TEST BUTTON on any one alarm and wait for each linked alarm to sound. (Due to signal timings each alarm may trigger at the same time making it difficult to detect a faulty alarm). Please perform a test from each alarm in the system to ensure every alarm is successfully linked.

Install the alarms around your home then test again with the alarms in position to ensure there are no radio range issues.

LINKING ADDITIONAL ALARMS

To add a new alarm to an existing system complete step 1 and 2 for all new alarms.

Open any already linked alarm and press the white RF button on the radio pattress to enter linking mode, the red and green led will flash as in step 3.1.

Repeat step 3.2 for all new alarms.

Press the white button on the already linked alarm to complete the process.

DEVICE RESET

To reset the pattress and restore factory settings, Open the alarm device and hold down the white RF button until the light turns RED. This will restore factory settings and unlink all devices, the light will flash green twice per second as in step 1.1.

Fireblitz Extinguisher Ltd.
Units 15-17 Manford Industrial Estate,
Manor Road. Erith, Kent DA8 2AJ

Telephone: 01322 342238
TECHNICAL HELPLINE 0800 008 6568
Text on 07885 831239
Email:customerservices@fireblitz.co.uk
For online pairing tutorial video visit: www.fireblitz.co.uk/support/

FireHawk Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>