PRODUCT SPECIFICATION
- Effect: 400W/600W/800W/1000W
- Operating voltage: 220-240V~50-60Hz
- IP Rating: IP24
- Frequency: 2405-2480MHz
- Power level: 0.87dBm
- Included 1.6 m cable and plug.
USE
USE WITHOUT PROGRAM
- Insert the power plug and turn on the power switch. The display will show the temperature.
- Chose manual mode by pushing the “OK” button until the MA symbol is shown in the display.
- When the environment temperature is below set temperature, the heater will start automatically. The heating icon will be shown in the display.
- Press “+” or “-”to set the desired temperature. The temperature can be adjusted between 5-35C. Factory default setting is 19C . Press and hold “+” or “-” to adjust the temperature in a faster speed.
USE WITH PROGRAM
- Insert the power plug and turn on the power switch. The display will show the temperature.
- Chose auto mode by pushing the “OK” button until the AU symbol is shown in the display.
- Press and hold “OK” for 5 seconds, and the icon will flash. (Refer to Zigbee IM of the panel heater for further instructions).
- Proceed with program settings in your Zigbee Smart hub.
- The heater could be turned off in the app. After heater is turned off through the app and needs to be turned on from the product. Press the power switch twice, press one time to return the switch to Off mode, press it again to go to On mode, then the heater will be turned on.
SAFETY
Do not cover the heater surface, the heater can become very hot and must be placed at a safe distance from flammable material. Disconnect power during maintenance. If using an extension cord it must be as short as possible and be extended when the oven is on.
FEATURES
-
Open window detection
- Press and hold “+“ and ”OK“ for five seconds to enter the open window detection settings. The open window icon will be flashing. Then press “+”/”-”to choose «ON» or «OFF». Press “OK” or after five seconds without operating the display, and the setting will be saved. The default factory setting for this function is off.
- If «ON» is selected, the window detection function is activated and the open window icon will be visible in the display. When temperature drop is detected, the appliance will automatically enter anti-freeze mode (heater works at 7C, with open window icon flashing). If temperature rises, the appliance will go back to previous working mode. You can also press any button to go back to previous mode. Choose «OFF» to deactivate the detection function.
-
Memory function
The heater has a memory function and will automatically return to the desired temperature after a power cut. -
Child Lock
- Press and hold “+“ and ”–“ for five seconds, until “CC” shows on the display. Child lock is now activated.
- Repeat procedure to deactivate this function. Child lock can also be activated / deactivated in your smart hub.
-
Reset the thermostat to default
Press and hold “–“ and ”OK“ for five seconds and the display will flash three times. After 30 seconds without being operated, the displays light will then turn off. Press any key to light it again. -
Information before first time use
The heater should be set to maximal temperature for 30 minutes to burn the element clean. Some smell may occur.
ASSEMBLY OF THE HEATER
- Drill holes in the wall. Distance between holes: See the form (a).
- Attach the clips onto the wall.
- Push the heater into the clips and use screws to thighten the clips.
INSTALLATION INSTRUCTION